● Parameter Loader 

This software enables various settings for the paperless recorder to be performed on the PC.   

The Parameter Loader can be used to read the settings data stored on the SD memory card, or 

create or change settings data. 

 

  Select  [All  Programs] 

–  [VM7000A]  and  then  [Parameter  Loader]  from  the

 

[Start]  menu 

The Parameter Loader will start. 

 

  Select  [Open]  from  the  [File]  menu,  and  select  the  desired  recorded  file  in  the  [Open] 

window.   

 

The same operation can be performed by selecting the [Open] icon on the toolbar. 

 

  Settings  data  that  has  been  created  should  be  saved  in  the  [Prm]  subfolder  of  the 

[Recorder]  folder  on  the  SD  memory  card.  Settings  data  can  be  loaded  into  this 

equipment. 

 

 

How to use the paperless recorder (Quick Reference) 
 

This section explains the preparation and operation procedures for storing measurement data.     

For details on how to use the paperless recorder, refer to the instruction manual for the  paperless 

recorder that is stored on the CD-ROM provided. 

 

  Caution 

Paperless Recorder 

  This equipment has optional functions, however these cannot be used. 

  The [Engineering] key on the menu screen is used for the factory adjustment only. 

      Do not change the settings for these functions. 

  Note that any loss of or damage to the data stored on the SD memory card falls out of the 

warranty. 

  This equipment allows you to change settings or format data as necessary. We recommend 

saving important data and settings to other media at regular intervals.    Refer to "Saving to 

SD Memory Card" on page 17 for information on how to save the settings to an SD memory 

card. 

  Do not operate the touch panel with pointed objects such as a pen. Doing so may scratch 

the screen. 

  There  may  be  unevenness  in  brightness  due  to  LCD  characteristics,  but  this  is  not  any 

faults. 

  When  other  functions  need  to  be  used,  thoroughly  read  the  instruction  manual  about  the 

handling of this equipment stored on the CD-ROM before using those functions. 

  If  this  equipment  is  used  for  anything  other  than  its  intended  purpose,  the  measurement 

accuracy cannot be guaranteed. Be sure to use this equipment only as a hygrometer. 

  If  the  "Offset"  or  "Gain"  settings  have  been  changed,  the  equipment  will  no  longer  be 

covered by the warranty terms including measurement accuracy. 

 
 

Содержание 7435-50

Страница 1: ...Instruction Manual No 7435 50 Multiple Measuring System Model SK 5RAD MR 3 4 Kanda kajicho Chiyoda ku Tokyo 101 0045 Japan URL http www sksato co jp english P 12...

Страница 2: ...ipment in an area subject to dust flammable gas explosive gas corrosive gas SO2 H2S etc etc Using this equipment in an environment with electrical noise may produce an unstable display or an increase...

Страница 3: ...supply voltage of this equipment 1 Power supply rating 100 to 240 VAC 50 60 Hz 25 VA max 2 Operating voltage range 85 to 264 VAC Note The power cord provided is exclusively used for 100 VAC If the equ...

Страница 4: ...ames product names system names etc are trademarks or registered trademarks of their respective companies Overview The operating principle of this equipment is based on the wet and dry bulb system whi...

Страница 5: ...s must specify this option when placing an order Components Sensor Hanging ring Used to suspend the sensor Wall mounting bracket Used to mount the sensor on a wall Power switch Turns the DC motor on a...

Страница 6: ...toward you while pushing the two knobs downward To close the cover push it straight back in place while holding down the knobs Terminal block Used to connect the power cord and sensor cable LAN conne...

Страница 7: ...11 12 13 14 15 16 17 18 19 Dry bulb temperature CH1 Wet bulb temperature CH2 A B B A B B Wire color R terminal color Red Red White Red Black Red Orange Blue Blue Blue Brown Blue Note For brushless mot...

Страница 8: ...en installing the sensor on a wall use the appropriate screws for the installing location The sensor can also be hanged by using the hook on the sensor head A tripod for hanging the sensor is optional...

Страница 9: ...ile phones Level places forward tilt 0 backward tilt between 0 and 30 Water supply method Caution When handling the string of wick use a pair of tweezers or wash your hands with soap to prevent the tr...

Страница 10: ...quipment was purchased or our service network If measured values are abnormal such as measured value exceeds the measuring range or the dry bulb temperature is lower than the wet bulb temperature B OU...

Страница 11: ...d the SD memory mark is lit in red in the memory status display section During this state never remove the card Doing so may damage the data and cause the equipment to fail You can freely change the r...

Страница 12: ...OM provided Installation Turn off any active applications currently running before installing this software If the previous version has been installed delete the software using Add Remove Programs in...

Страница 13: ...s optional functions however these cannot be used The Engineering key on the menu screen is used for the factory adjustment only Do not change the settings for these functions Note that any loss of or...

Страница 14: ...d In this state never remove the SD memory card MiniSD and MicroSD memory cards cannot be used If an adapter for MiniSD or MicroSD is used for these cards there is a risk of not being able to remove t...

Страница 15: ...ouching this area enables the screen title to be changed Time display This area displays the current date and time Trend changeover This area is used to switch the type of trend screen REAL or HIST No...

Страница 16: ...D memory card is mounted or an SD memory card that is mounted can be removed Light blue An SD memory card has been mounted Red The equipment is communicating with the SD memory card Data is being writ...

Страница 17: ...ry overwriting OFF Data is not overwritten when the SD memory card becomes full Storage format CSV data and binary data Recording type Instantaneous value Graph display Digital FUNC button Screen swit...

Страница 18: ...CH13 and dew point temperature CH14 Setting Main Touch this button to set up recording Items such as the recording interval can be set here LCD Touch this button to set the screen brightness and auto...

Страница 19: ...lly created when an SD memory card is mounted on this equipment To load the stored settings into the equipment touch Param load Selecting the desired settings from all the stored settings loads the se...

Страница 20: ...e Set the interval for recording measurements to a file The selectable range varies according to the specified value in Record Cycle File overwrite Select to overwrite data or not when the SD memory c...

Страница 21: ...interval is one second the maximum and minimum values of 10 values measured at intervals of 100 ms will be recorded OFF Trend data only is recorded on the Trend screen and is not recorded in the SD m...

Страница 22: ...erting an SD Memory Card into this equipment automatically creates a folder named Recorder where four subfolders will be created The subfolders are as follows Cap Contains image files bmp that are cap...

Страница 23: ...saved and read by this equipment Settings data created with the software provided Parameter Loader must be stored in this folder Data analysis Installing the analysis software Data Viewer from the CD...

Страница 24: ...e clamp convex part is placed and aligned with gloves of the upper and lower sections of the air intake tube At that time don t let the string get stuck or caught between the housing and air intake tu...

Страница 25: ...al strands warps Make a string by binding the remaining wraps of gauze 8 Put back the lower part of air intake tube clamp and insert the string into the water reservoir Follow steps 4 5 6 in Replacing...

Страница 26: ...s of operation If the motor needs to be replaced due to aging contact the store from which the equipment was purchased or our service network For the continuous operation for a long period of time sel...

Страница 27: ...y SD memory card SD max 2GB SDHC max 32GB Water resistance JIS C 0920 IP65 Only for the front of the display with the use of packing for the panel mount Power Requirements 100 to 240VAC 10 50 60Hz 25V...

Страница 28: ...customer misuse Out of warranty products will be repaired on charge basis Warranty during transportation The warranty during transportation only applies to the products that we arrange the shipment Th...

Отзывы: