Allowed numbers – the move to submenu for programming the telephone numbers 
accepted by the module. 

Tel. No. 1–32 beginning – for these functions it is required to enter the first digits (any 
number of digits), or complete telephone numbers, to which the calls can be made via 
SIM300CZ telephone – if the "Any number" option is not set. When the Any numbers 
option is set, the above mentioned telephone numbers are of no importance. The numbers 
to be entered must have the same form as the numbers dialed by the GSM telephone i.e. 
must contain area code, for instance: "602 123456", "58 5551122". If the initial digits are 
programmed, the dialed number must contain all these programmed digits at the beginning. 

Note:  The list of telephones 1–32 and the Any numbers option do not affect the 

selection of addressee of SMS messages. 

Messaging – submenu of functions for programming the data and options for messaging. 

Tel. 1–4 for mess. – telephone numbers to which messaging on violation and restoration 
of inputs, or activation and switch OFF of output OT4 will be sent. The telephone number 
programmed by this function must have a complete form including country and area codes 
or cellular network code. 

Mess. x2 for T. 1–4 – setting this option for a given telephone number will result in making 
a call twice to a dialed number and replaying the voice message each time – while 
executing the voice messaging. 

Tries for tel. 1–4 – number of attempts to send CLIP to telephone nos. 1–4. It is possible 
to program from 1 to 15 attempts. 

Ack. CLIP tel. 1–4 – with this option selected, the module will require that the user 
acknowledge receiving the CLIP sent to telephone nos. 1–4. 

SMS mess 1–4 fail – if you select this option, an SMS message will be sent to the 
telephone number, if the module, having completed all the attempts, receives no 
acknowledgement of the CLIP reception from the selected telephone. 

SMS violat. In.1–4 – contents of SMS message to be sent to cellular telephone number 
after violation of a given input (indication on LCD display i

Æ

I). It is possible to choose 

a standard contents or to enter your own message. (up to 32 characters). 

SMS fail. line – contents of SMS message to be sent to cellular telephone number after 
activating the output OT4. You can select standard contents

 

(

phone line failure

)

 or enter 

your own message (up to 32 characters). 

SMS restor. In.1–4 – contents of SMS message to be sent to cellular telephone number 
after the input is restored to normal state (I

Æ

i). 

SMS restor. line – contents of SMS message to be sent to cellular telephone number after 
restoration of input OT4 to normal state (telephone line available and operative). 

SMS test  – contents of SMS message to be sent to cellular telephone number in a test 
message. 

SMS tst. w.state – enabling this option will result in information on the current status of the 
module outputs/inputs and the telephone line being attached to the SMS contents for test 
transmission. 

TL ok, mess.IN1–4 – if this option is disabled for the particular zone, messages from 

 this zone are sent only in case of the cable telephone line failure. 

In. 1–4 -> Tel. and F. L. -> Tel. – programming the options for messaging. These options 
are used for selecting telephone numbers, to which the messages shall be sent after 
violating the input or after failure of telephone line, and for choosing the type of messaging 
(SMS/CLIP/VOICE). The option is set by pressing push-button CHANGE. The successive 
pressing makes the character display at the telephone numbers: 

Содержание GSM-4S

Страница 1: ...COMMUNICATION MODULE GSM 4S USER MANUAL Program version 4 11 gsm4_en 07 08...

Страница 2: ...S Manufacturer SATEL sp ka z o o ul Schuberta 79 80 172 Gda sk POLAND tel 48 58 320 94 00 fax 48 58 320 94 01 Product description The GSM 4S communication module designed to interact with the SIM300CZ...

Страница 3: ...SSAGING 17 10 1 SMS MESSAGES 18 10 2 VOICE MESSAGING 18 10 3 CLIP 19 10 3 1 CLIP with acknowledgement 19 10 3 2 CLIP without acknowledgement 19 11 TRANSMITTING SMS MESSAGES 20 11 1 DESCRIPTION OF THE...

Страница 4: ...LIP Three outputs for controlling the electrical devices e g by relays directly connected to the module Output for signaling the telephone line failure and the cellular line failure Test messaging mon...

Страница 5: ...f cellular telephone can generate the proper form of these signals Some models of cellular telephone have a special function permitting the DTMF control in such case this special function is to be act...

Страница 6: ...nd essential elements which are important for connecting and programming the GSM 4S module For power supply of external equipment you should use the V V outputs whose max current load must not exceed...

Страница 7: ...nu The SIM300CZ telephone will not start dialing if the antenna signal level is equal to zero The status of inputs and outputs are displayed alternately 2 s 2 s at last four characters of top line on...

Страница 8: ...picked up connection type modem connection voice connection telephone number or message status of inputs outputs see table 1 antenna signal level RS 232 port receiving data sending data GSM telephone...

Страница 9: ...bles of telephone lines public exchange line subscriber s and extension line to the alarm control panel and telephone set can be connected to the terminal strip or to the telephone jacks located on th...

Страница 10: ...he countdown to make possible a change of the PIN code for the right one The GSM phone trbl message is shown on the display until the SIM300CZ telephone logs in the cellular network This state may las...

Страница 11: ...ne number and then initiates dialing and getting connection via the SIM300CZ telephone The corrections are necessary since the module gets the dialed telephone number as when connecting via the cable...

Страница 12: ...monitoring station from version 4 07 only supports SMS monitoring related to the input status of the GSM module located on the site e g GSM 4S or GSM LT 2S Changing the status of the device inputs wil...

Страница 13: ...lowing way enabling output if inactive the output will be switched on if active the output status will not change If a cut off time has been programmed for the output it will be disabled after the tim...

Страница 14: ...passing option can be disabled by deselecting IN1 bps manual option The remote control is implemented similarly to the remote control of the module outputs status The input can be automatically bypass...

Страница 15: ...nd generate three short sounds beeps acknowledging that the module is ready to have the DTMF controlling Note When receiving a call the module applies ringing tone to extension line for the duration e...

Страница 16: ...ne number After decoding the password by the module an appropriate action will be initiated depending on the password transmitted E G Recognizing the password entered into the module memory by the fun...

Страница 17: ...line in good working order the telephone line out of order In the test field the module will send the currently programmed number of days hours and minutes of the test transmission period In the tele...

Страница 18: ...controlling OT2 bypassing IN2 NEXT controlling OT3 bypassing IN3 OK switching OFF all outputs bypassing IN4 The manual bypassing unbypassing the inputs is also implemented by the GSM 4S module s push...

Страница 19: ...g a given number twice two phone connections with replaying the message each time Another form of messaging is the test transmission In order to inform the user of its operability the module will send...

Страница 20: ...rom SMS will be displayed on LCD display and the module will go into awaiting for SMS message mode for the duration of approx 110 seconds Send SMS message previously prepared from another cellular tel...

Страница 21: ...an option to early reject the connection but if he carries out this action too early the module will repeat the call Answering the call either by the user or automatically by the voice mail is recogni...

Страница 22: ...l be active and also determine the way of messaging SMS CLIP VOICE functions In 1 4 Tel Rest 1 Tel F L Tel Rest L Tel Test Tel If the voice messaging is selected and several inputs can activate this m...

Страница 23: ...2 2 A 0 E 0 0 7 A 8 11 2 SENDING SMS MESSAGES FROM A STATIONARY TELEPHONE SET The GSM 4S module user has an option to send SMS messages form a stationary telephone set which generates DTMF signals an...

Страница 24: ...espond to the pager station number or any of the outgoing numbers 4 seconds since dialing the last digit the module will recognize the dialing as completed and will proceed to convert the number If an...

Страница 25: ...d consider the monitoring attempt unsuccessful After a specified number of unsuccessful attempts function Num pan attempts the module can send an SMS message its contents is determined by function GPR...

Страница 26: ...gram with the default access code 1234 module DSR module RTS module RXD module TXD COM SERIAL PORT RS 232 view of connector at the GSM 4 module board comp DTR comp CTS comp TXD comp RXD GND 2 3 4 5 8...

Страница 27: ...module by clicking on the icon 8 If necessary you can save the programmed data as a file on the computer disk 9 Disconnect the cable used for programming Note Never carry out functional test of the m...

Страница 28: ...ure 11 This tab allows the user to configure the basic working parameters of the module The parameters programmable in the GSM 4 tab correspond to the control functions and have been reviewed in secti...

Страница 29: ...G TAB Figure 12 The tab enables messaging parameters to be configured The parameters programmable in the Telephone messaging tab correspond to the control functions and have been reviewed in section D...

Страница 30: ...28 13 3 CONTROL INPUTS OUTPUTS TAB Figure 13 The parameters programmable in the Control Inputs Outputs tab correspond to the control functions and have been reviewed in section Description of service...

Страница 31: ...ransmission data are not programmed All the options are discussed in detail in section Description of service functions page 36 Monitoring the module inputs requires that the format and codes of event...

Страница 32: ...module to display a suitable message and wait for entering the code Unless the entered code is valid the module will only enable the user to enter the service mode when all the settings are deleted T...

Страница 33: ...o 3 Outgoing no 4 Perm prefix 1 Perm prefix 2 Perm prefix 3 Perm prefix 4 Prefix to erase Prefix to add Allowed numbers Tel No 1 begin Tel No 2 begin Tel No 32 begin Messaging Tel 1 for mess Tel 2 for...

Страница 34: ...L ok mess IN4 IN1 Tel IN2 Tel IN3 Tel IN4 Tel F L Tel Rest 1 Tel Rest 2 Tel Rest 3 Tel Rest 4 Tel Rest L Tel Test Tel Test period Mess priority Mess sounds SMS control SMS bypass IN1 SMS bypass IN2 SM...

Страница 35: ...IN3 DTMF unbyps IN4 DTMF unbyps all DTMF check inps DTMF OT1 on DTMF OT2 on DTMF OT3 on DTMF OT1 off DTMF OT2 off DTMF OT3 off DTMF chng OT1 DTMF chng OT2 DTMF chng OT3 DTMF OT123 off DTMF OT123 on DT...

Страница 36: ...1 bps manual IN2 bps manual IN3 bps manual IN4 bps manual Bypassing input Bypassed inputs OT1 cut off t OT2 cut off t OT3 cut off t OT3 t l trbl OT4 only GSM IN1 Outputs IN2 Outputs IN3 Outputs IN4 Ou...

Страница 37: ...SMS Skip audio St 1 SMS tel n St 2 SMS tel n St 1 SMS format St 2 SMS format Num pan attempts GPRS trouble tel GPRS trbl SMS IN1 violat code IN2 violat code IN3 violat code IN4 violat code IN1 restore...

Страница 38: ...xt field to the right or return to the first field on the left side of the number or password entered Pressing the push button OK results in storing the entered data and in exiting from the function 1...

Страница 39: ...minals If this option is unchecked the cable line is the basic one Trbl switch l when this option is selected the module in case of cable telephone line failure will automatically switch over to makin...

Страница 40: ...nt to telephone nos 1 4 SMS mess 1 4 fail if you select this option an SMS message will be sent to the telephone number if the module having completed all the attempts receives no acknowledgement of t...

Страница 41: ...messaging When this option is not set the messaging shall be sent after the user hangs up Mess sounds setting this option for voice messaging makes the module generate sounds informing which inputs ha...

Страница 42: ...test transmission 1 transmission period equal to 2 h 58 min 2 transmission period equal to 5 h 57 min 3 transmission period equal to 11 h56 min 4 transmission period equal to 23 h55 min 5 transmissio...

Страница 43: ...nsit the sensitivity of each input The following values in msec can be programmed 20 40 60 80 100 130 160 200 250 300 400 500 600 800 1000 1275 Input 1 4 restore time from the end of violation after w...

Страница 44: ...ut s 6 check output status in response the device will generate beeps o 1 short beep output disabled o 2 short beeps output enabled Controllable out selection of outputs which can be locally enabled d...

Страница 45: ...when the Station address is to be entered in mnemonic form 4 bytes 000 000 000 000 each of which can take the value from 0 to 255 Tst INTEGRA cn test the status of connection to INTEGRA control panel...

Страница 46: ...nning end of violation event code I zone module user J partition For 4 2 format events the form will be Event iiii cc 20 ASCII characters and for Contact ID format Event iiii q ccc ss xxx 24 ASCII cha...

Страница 47: ...ogrammed modem for another one by means of an SMS message format code modem format 00 auto 01 300 V 21 02 1200 V 22 03 1200 75 V 23 04 2400 V 22bis 05 2400 V 26ter 06 4800 V 32 07 9600 V 32 12 9600 V...

Страница 48: ...elds Outgoing No 1 4 not necessarily in two first fields The changes entered in the service functions have in majority immediate results i e immediately after the exit from the function by pressing pu...

Страница 49: ...telephone number of the Service While programming at the alarm control panel the telephone numbers for messaging it is required to choose one of three ways of getting connection the letter D indicates...

Страница 50: ...code e g for Poland 48 instead of 48 17 TECHNICAL DATA Supply voltage 12 V DC 15 Outputs current carrying capacity 4 x 50 mA Current carrying capacity supply output V V 300 mA Maximum current consump...

Страница 51: ...SATEL sp z o o ul Schuberta 79 80 172 Gda sk POLAND tel 48 58 320 94 00 info satel pl www satel pl...

Отзывы: