31
Neutral Measurement
Z
nm
When the Neutral Measurement
application is selected, you can use your
weighing instrument to measure the
length, surface and volume of parts that
have roughly the same specific weight.
The
o symbol is displayed as the weight
unit.
Features:
– Store the weight on the weighing
instrument as reference weight
– Enter reference weight using a bar code
scanner
– Enter tare weight using a bar code
scanner
– Toggle the display between weight
and calculated value by pressing
w
– Info mode for display of reference
weight by pressing
w
(> 2 sec)
To calculate the result correctly, the
average weight of a reference quantity
must be known (in the example below,
the reference is 1 meter of electrical
cable). There are 2 ways to do this with
the Combics:
– By placing the number of parts defined
for the reference value on the weighing
instrument and pressing
O
to store
the average piece weight.
The reference value is shown in the
numeric display, and can be changed
by pressing
r
.
How the reference weight is calculated
depends on the menu setting for reso-
lution (3.9). Either the value is rounded
off in accordance with the display
resolution, or the display resolution is
increased 10-fold (+1 decimal place) or
100-fold (+ 2 decimal places), or maxi-
mum internal resolution is applied.
– By entering the reference weight (i.e.,
the weight of one piece) using a bar
code scanner (menu setting: “Setup>
Bar code > Store value as reference
(
ref
)"). In this case, the value is stored
as a reference automatically, without
pressing the
O
key.
This value remains active in the reference
memory until you delete it by pressing
c
, overwrite it or until you select
a different application. It also remains
stored after you switch off the Combics.
– Tare function:
1) If you store a tare (weight value) by
pressing the
)
key, you can later
enter a tare value manually. The tare
value you enter is added to the stored
tare value.
Setting: menu code 3.25.1 (factory
default)
2) A tare value entered manually over-
writes a stored tare value (weight value).
If you enter a tare value manually, a
tare value (weight value) stored later
overwrites the manually entered value.
Setting: menu code 3.25.2
Operating menu setting:
APPL
:
Z
nm
:
3.25.
Application Parameters: Neutral Measurement
3. 5.
Minimum Load for Automatic Taring
and Automatic Printing
3. 5. 1 * 1 digit
3. 5. 2
2 digits
3. 5. 3
5 digits
3. 5. 4
10 digits
3. 5. 5
20 digits
3. 5. 6
50 digits
3. 5. 7
100 digits
3. 5. 8
200 digits
3. 5. 9
500 digits
3. 5.10
1000 digits
3. 6.
Minimum Load for Initialization
3. 6. 1 * 1 digit
3. 6. 2
2 digits
3. 6. 3
5 digits
3. 6. 4
10 digits
3. 6. 5
20 digits
3. 6. 6
50 digits
3. 6. 7
100 digits
3. 6. 8
200 digits
3. 6. 9
500 digits
3. 6.10
1000 digits
3. 7.
Automatic Taring:1st Weight Tared
3. 7. 1 * Off
3. 7. 2
On
3. 8.
Start Application with Most Recent
Application Data when Combics
is Switched On
3. 8. 1
Automatic (on)
3. 8. 2 * Manual (off)
3. 9.
Resolution for Calculation
of Reference Value
3. 9. 1 * Display resolution
3. 9. 2
Display reso 1
decimal place
3. 9. 3
Display reso 2
decimal places
3. 9. 4
Internal resolution
3.10.
Decimal Places for Display of Results
3.10. 1 * None
3.10. 2
1 decimal place
3.10. 3
2 decimal places
3.10. 4
3 decimal places
3.11. Storage
Parameter
3.11. 1* At stability
3.11. 2
At increased stability
3.13.
Reference Weighing Instrument
3.13. 1* Off
3.13. 2
WP1
3.13. 3
WP2
3.25. Tare
function
3.25. 1* The tare value entered is added to
the stored tare value
3.25. 2
Overwritable tare value
Содержание CH1NE
Страница 102: ...CH Platform Dimensions Scale Drawings CH G CH E 102 ...
Страница 108: ...108 ...
Страница 109: ...109 ...
Страница 110: ...110 ...
Страница 111: ...111 ...
Страница 112: ...112 ...
Страница 113: ...113 ...
Страница 114: ...114 ...
Страница 115: ...115 ...
Страница 116: ...116 ...
Страница 117: ...117 ...
Страница 118: ...118 ...
Страница 120: ......