SECTION 4
PART#
49-057 REV K
SAPPHIRE SCIENTIFIC RAGE
®
35
TROUBLESHOOTING:
ENGINE
PROBLEM
CAUSE
SOLUTION
Engine stops running:
While
doing normal cleaning, the
engine stops running
Engine is out of gasoline
Add gasoline to the fuel tank.
Waste tank is full
Empty waste tank.
Main circuit breaker on the
control panel has been tripped.
After inspecting the unit to determine
the cause of the tripped circuit breaker,
press the reset button.
Defective fuel pump.
Replace fuel pump.
Defective float switch inside the
waste tank.
Check switch for proper operation.
Replace as necessary.
Oil pressure switch on engine
has shut down, due to
insufficient oil pressure.
Refer to the Engine Operation and
Maintenance Manual.
DO NOT
restart
the engine until the cause is
determined and corrected.
No ignition in the engine or
engine is malfunctioning.
Refer to the Engine Operation and
Maintenance Manual.
Heat exchanger leaks
NOTE:
The heat exchanger will
produce water condensation
discharge at times during
normal operation.
DO NOT
confuse this with a leak.
Engine/vacuum exhaust heat
exchanger is damaged from
frozen water.
Inspect heat exchanger for leaks.
Visually inspect for damage. Pressure
check after removing from the unit.
(Maximum test pressure 1200 PSI).
Loss of temperature:
The heat
output of the unit is LESS than
normal.
Solenoid switch stuck open
Replace temperature switch
Engine RPM is low.
Reset engine RPM.
Defective temperature gauge.
Test gauge and sensor. Replace failed
component.
Automatic waste pump is
malfunctioning or not
operating normally.
Defective waste pump float
switch.
Replace float switch.
Broken diaphragm(s).
Replace diaphragm(s).
Weak battery.
Charge or replace battery if needed.
Check charging station.
Pump-out circuit breaker on
control panel has been tripped.
After inspecting waste pump to
determine the cause of the tripped
circuit breaker, press the reset button.
Inspect check valve for debris
or damage.
Clean or replace if necessary.
TROUBLESHOOTING:
BLOWER / VACUUM PUMP
PROBLEM
CAUSE
SOLUTION
Excessive Vacuum
Improper throttle adjustment.
Adjust throttle to set desired vacuum
pressure.
Vacuum relief valve requires
adjustment.
Readjust the vacuum relief valve to
13”Hg
Содержание rage
Страница 1: ...Service and Operation Manual 2604 Liberator Dr Prescott AZ 86301 1 928 445 3030...
Страница 16: ...SECTION 2 PART 49 057 REV K SAPPHIRE SCIENTIFIC RAGE 12 DIMENSIONAL DIAGRAM REAR MOUNT TANK...
Страница 17: ......
Страница 46: ...SECTION 5 PART 49 057 REV K SAPPHIRE SCIENTIFIC RAGE 40 CONSOLE ASSEMBLY DETAIL 1...
Страница 47: ...SECTION PART 49 057 REV K SAPPHIRE SCIENTIFIC RAGE 41 CONSOLE ASSEMBLY DETAIL 2...
Страница 48: ...SECTION 5 PART 49 057 REV K SAPPHIRE SCIENTIFIC RAGE 42...
Страница 49: ...SECTION PART 49 057 REV K SAPPHIRE SCIENTIFIC RAGE 43 69 544 ASSY BEZEL AND PANEL 1 16...
Страница 50: ...SECTION 5 PART 49 057 REV K SAPPHIRE SCIENTIFIC RAGE 44 69 445 ASSY BEZEL AND PANEL 17 25...
Страница 51: ...SECTION 5 PART 49 057 REV K SAPPHIRE SCIENTIFIC RAGE 45...
Страница 52: ...SECTION 5 PART 49 057 REV K SAPPHIRE SCIENTIFIC RAGE 46 69 710 VACUUM PUMP ASSEMBLY...
Страница 53: ...SECTION 5 PART 49 057 REV K SAPPHIRE SCIENTIFIC RAGE 47 69 432 ASSEMBLY VACUUM RELIEF...
Страница 54: ...SECTION 5 PART 49 057 REV K SAPPHIRE SCIENTIFIC RAGE 48 69 610 ASSY PRESSURE PUMP Pulse Pump 46 056 Pump 46 072...
Страница 57: ...SECTION 5 PART 49 057 REV K SAPPHIRE SCIENTIFIC RAGE 51 69 260 MANIFOLD BLOCK ASSEMBLY...
Страница 63: ...SECTION 5 PART 49 057 REV K SAPPHIRE SCIENTIFIC RAGE 57 ELECTRICAL DIAGRAM...
Страница 64: ...SECTION 5 PART 49 057 REV K SAPPHIRE SCIENTIFIC RAGE 58 HOSE IDENTIFICATION FLOW DIAGRAM...