PRESSURE REGULATOR
Lubricate the o-rings in the pressure regulator
every
100 hours.
Use only o-ring lubricant (Part
#13-003).
VACUUM HOSES
To ensure maximum hose life,
SAPPHIRE
SCIENTIFIC
recommends that you wash out
the hoses with fresh water
daily.
Microban QGC
cleaner as the best product for cleaning and
sanitizing the wands and hoses as well as other
parts of the system
BATTERY
!
Explosive gases, Dangerous acid!
Batteries contain sulfuric acid. To prevent acid
burns, avoid contact with skin, eyes and clothing.
Batteries also produce explosive hydrogen gases
while charging. To prevent fire or explosion,
charge batteries only in a well ventilated area.
Keep sparks, open flames, as well as any other
sources of ignition away from batteries at all
times. Remove all jewelry prior to servicing
batteries. Keep batteries out of the reach of
children.
Before disconnecting the negative (−) ground
cable, ensure that all switches are in the OFF
position. If ON, a spark could occur at the
ground connection terminal which could cause
an explosion if hydrogen gas or gasoline
vapors are present. ALWAYS disconnect the
negative (−) terminal first.
1. If you do not have a maintenance free sealed
battery, check the fluid level in the battery at
least
once a week.
If low, fill to the
recommended level
ONLY
with distilled water.
DO NOT
overfill the battery. Early failure or
poor performance will result due to loss of
electrolyte.
2. Keep cables, terminals and external surfaces of
the battery clean and dry. A buildup of corrosive
acid or grime on the external surfaces could
cause the battery to self-discharge.
3. Battery terminals should be cleaned every
100
hours
to prevent corrosion buildup. Wash the
cables, terminals and external surfaces with a
mild baking soda and water solution. Rinse
thoroughly with fresh water.
DO NOT
allow
baking soda to enter the battery cells, as this will
destroy the electrolyte, resulting in battery failure
HIGH PRESSURE SOLUTION
HOSES
Inspect your high-pressure solution hoses for
wear after the first
100 hours.
Thereafter, inspect
every
25 hours.
If the hoses show any signs of
damage or impending rupture, replace the hoses.
!
NEVER attempt to repair high-pressure
solution hoses. Repairing high-pressure
solution hoses may result in severe burns and
serious injury.
All high-pressure solution hoses must be rated
for 3000 PSI at 250 deg. F. Thermoplastic
hoses do not meet this requirement and should
not be used. Severe burns and injury may
result if the hoses do not meet these
requirements.
Содержание rage
Страница 1: ...Service and Operation Manual 2604 Liberator Dr Prescott AZ 86301 1 928 445 3030...
Страница 16: ...SECTION 2 PART 49 057 REV K SAPPHIRE SCIENTIFIC RAGE 12 DIMENSIONAL DIAGRAM REAR MOUNT TANK...
Страница 17: ......
Страница 46: ...SECTION 5 PART 49 057 REV K SAPPHIRE SCIENTIFIC RAGE 40 CONSOLE ASSEMBLY DETAIL 1...
Страница 47: ...SECTION PART 49 057 REV K SAPPHIRE SCIENTIFIC RAGE 41 CONSOLE ASSEMBLY DETAIL 2...
Страница 48: ...SECTION 5 PART 49 057 REV K SAPPHIRE SCIENTIFIC RAGE 42...
Страница 49: ...SECTION PART 49 057 REV K SAPPHIRE SCIENTIFIC RAGE 43 69 544 ASSY BEZEL AND PANEL 1 16...
Страница 50: ...SECTION 5 PART 49 057 REV K SAPPHIRE SCIENTIFIC RAGE 44 69 445 ASSY BEZEL AND PANEL 17 25...
Страница 51: ...SECTION 5 PART 49 057 REV K SAPPHIRE SCIENTIFIC RAGE 45...
Страница 52: ...SECTION 5 PART 49 057 REV K SAPPHIRE SCIENTIFIC RAGE 46 69 710 VACUUM PUMP ASSEMBLY...
Страница 53: ...SECTION 5 PART 49 057 REV K SAPPHIRE SCIENTIFIC RAGE 47 69 432 ASSEMBLY VACUUM RELIEF...
Страница 54: ...SECTION 5 PART 49 057 REV K SAPPHIRE SCIENTIFIC RAGE 48 69 610 ASSY PRESSURE PUMP Pulse Pump 46 056 Pump 46 072...
Страница 57: ...SECTION 5 PART 49 057 REV K SAPPHIRE SCIENTIFIC RAGE 51 69 260 MANIFOLD BLOCK ASSEMBLY...
Страница 63: ...SECTION 5 PART 49 057 REV K SAPPHIRE SCIENTIFIC RAGE 57 ELECTRICAL DIAGRAM...
Страница 64: ...SECTION 5 PART 49 057 REV K SAPPHIRE SCIENTIFIC RAGE 58 HOSE IDENTIFICATION FLOW DIAGRAM...