SECTION 4
40
SAPPHIRE SCIENTIFIC MODEL 370 SS
®
PART#
49-038 REV F
TROUBLESHOOTING:
CHEMICAL SYSTEM
PROBLEM
CAUSE
SOLUTION
Loss of chemical:
With the
cleaning tool valve open, no
chemical
Chemical pump check valve(s)
is clogged
Remove any debris from the chemical
check valve(s). Replace chemical
check valve(s) or seals, if necessary.
Chemical prime/on-off valve or
chemical metering valve is
defective.
Replace valve(s).
Chemical pump diaphragm is
ruptured.
Disassemble the chemical pump and
replace the damaged diaphragm.
Defective cylinder in the water
pump.
Measure the pump volume. If the
pump volume is less than normal, refer
to “Loss of Pump Volume” in the
Troubleshooting section in this
manual.
Содержание 370 SS
Страница 1: ...Service and Operation Manual 2604 Liberator Prescott AZ 86301 1 928 445 3030 ...
Страница 5: ......
Страница 16: ...SECTION 2 11 SAPPHIRE SCIENTIFIC MODEL 370 SS PART 49 038 REV F DIMENSIONAL DIAGRAM REAR MOUNT TANK ...
Страница 47: ...SECTION 5 42 SAPPHIRE SCIENTIFIC MODEL 370 SS PART 49 038 REV F 70 370 CONSOLE 370 SS BOM TABLE ...
Страница 48: ...SECTION 5 43 SAPPHIRE SCIENTIFIC MODEL 370 SS PART 49 038 REV F 70 370 CONSOLE 370 SS VIEW 1 OF 2 ...
Страница 49: ...SECTION 5 44 SAPPHIRE SCIENTIFIC MODEL 370 SS PART 49 038 REV F 70 370 CONSOLE 370 SS VIEW 2 OF 2 ...
Страница 50: ...SECTION 5 45 SAPPHIRE SCIENTIFIC MODEL 370 SS PART 49 038 REV F 69 589 ASSY FRAME ENCLOSURES VIEW 1 OF 2 ...
Страница 51: ...SECTION 5 46 SAPPHIRE SCIENTIFIC MODEL 370 SS PART 49 038 REV F 69 589 ASSY FRAME ENCLOSURES ...
Страница 62: ...SECTION 5 57 SAPPHIRE SCIENTIFIC MODEL 370 SS PART 49 038 REV F 69 429 ASSY THERMAL WELL BOM TABLE ...
Страница 63: ...SECTION 5 58 SAPPHIRE SCIENTIFIC MODEL 370 SS PART 49 038 REV F 69 429 ASSY THERMAL WELL 24 46 ...
Страница 70: ...SECTION 5 65 SAPPHIRE SCIENTIFIC MODEL 370 SS PART 49 038 REV F ELECTRICAL DIAGRAM WATER PUMP ...
Страница 71: ...SECTION 5 66 SAPPHIRE SCIENTIFIC MODEL 370 SS PART 49 038 REV F ...