Configuring Monitoring Conditions
In [VIEW], select “CAM1” or “CAM2” and then configure the monitoring conditions by clicking each menu item in
the sub menu.
Switching between Monitoring Conditions
In [VIEW], select “CAM1” or “CAM2”. The monitoring conditions configured for the selected view setting are now
applied to the camera.
Configure the lens iris according to the brightness of the subject displayed on the screen.
The configured settings will be applied to “CAM1” or “CAM2”, whichever you selected under [VIEW].
1
In [SENSE UP], select the electronic sensitivity boosting power.
OFF, x2, x4, x8, x16, x32
Enabling the electronic sensitivity boosting function causes the following
:
The exposure time of the camera's image sensing device will be increased automatically in dark
situations. This may result in conspicuous afterimages, blurs, and white spots if the subject
includes any moving object.
If [DAY/NIGHT] is set to “AUTO”, the electronic sensitivity boosting function will work only for
black/white video images. (For VDC-HD3300P/VDC-HD3300)
[SHUTTER] is set to “OFF”, preventing you from configuring the electronic shutter setting
(“SHORT” or “LONG”).
No motion sensor type can be selected in [MOTION] on the ALARM SETTINGS screen.
You cannot configure the electronic sensitivity boosting function in the following case:
When [AGC] is set to “OFF”.
A motion sensor type is selected in [MOTION] on the ALARM SETTINGS screen.
2
In [LEVEL], select the video signal level and click
SET
.
0 (dark) to 100 (bright)
Working with Administrator Configuration Screens 16/50