3-8
Control of 3-WAY ECO-i SYSTEM
1
2
3
4
5
6
7
8
2. Wireless Remote Controller
1-5. Timer Operation
1-6. Adjusting the Wind Direction
When setting the timer, make sure the current time on the remote control is accurate.
The timer’s clock can only be set when the display of the remote control is ON.
After setting the timer, put the remote control in a place where its signal will reach the
receiver of the indoor unit. (When the time set for the timer is reached, a signal is sent
from the remote control to Start/Stop the unit.)
Using the Timer
1. Press either
/
of the
or
, and while the time is being displayed,
if you press
/
again, a scheduled time can be set.
The time last set on the timer is displayed.
“--:--“ indicates time to change the batteries.
2. Press either
/
of the
or
and set the timer to the desired time.
Every time you press
/
, the time changes in 10 minute increments.
If you press and hold the button, the time changes quickly.
3. After setting the timer, if you press
, the time you set changes to a steady display,
indicating settings are complete.
After the timer setting is displayed for three seconds, the display reverts to the current time.
1,2
3
Combining ON and OFF Timers
Setting the ON and OFF timers, respectively.
Checking the timer setting
If you press either
/
for the
or the
, the scheduled time is displayed for four seconds.
When no timer setting has been made, it displays --:--. (Initial Setting)
Changing a timer setting
Canceling a timer setting
If you press [CANCEL], the timer setting is canceled.
If you wish to cancel the setting for either the
or the
timer, press
/
or the desired timer and when the
scheduled time is displayed, press [CANCEL].
Using the same timer setting every day
If you press
for 2 or more seconds, “
” is displayed and the
ON timer
or the
OFF timer
will operate the unit at
the same time every day.
If you press
again for two seconds or more, “
” goes off and the timer operates just once.
Press
/
for the
or the
, and then when the timer setting is displayed, press
/
for the timer again.
Please face the flap (up-down wind
direction plate) downwards. If it faces
upwards, the warm air will not reach
the floor level.
In the Heat Mode
Please face the flap (up-down wind
direction plate) upwards. If the plate
faces downwards, condensation
may form and drip from around
the air outlet.
In the Cool and Dry Modes
In the Fan Mode
In All Modes
Displays with Swing Stopped
Initial Setting
Initial Setting
Initial Setting
Moves Constantly
Fan/Heat Modes
Cool/Dry Modes
Never try to manually move the flap (up-down wind direction plate) that is operated by the remote control.
When the unit stops, the flap (up-down wind direction plate) automatically faces downwards.
When the unit is in heating standby, the flap (up-down wind direction plate) faces upward. Also, bear in mind that the
flap starts swinging after the heating standby mode is released, but the display on the remote control indicates
Auto Flap during standby heating as well.
RCS-SH80BG.WL/RCS-TRP80BG.WL / RCS-SS80BG.WL / RCS-XM18BG.WL / Indoor Unit (K type)
Setting the Wind Direction
While the unit is operating, every time you press , the direction the flap faces changes.
Setting Flap to Swing
If you press
to set the flap (up-down wind direction plate) in its most downward
facing position, and then press
again,
is displayed and the flap swings
automatically up and down.
Stopping Flap Swing
If you press
again while the flap is swinging, you can stop the flap from swinging
and set it in place as desired. Thereafter, if you press
, you can set the wind direction
starting from the most upward position.
When the unit is in the Cool or Dry modes, the flap cannot stop facing downwards.
If you try to stop the flap from swinging while it is facing downwards, it will continue
moving until it is in the third position from the top.
RCS-BH80BG.WL
The available functions differ depending on the indoor unit being used. The wind
direction cannot be set via remote control for any models other than those noted below.
For more information, please refer to the users’ manual that came with your indoor unit.
Four-direction Ceiling Cassette Models, Bi-directional Ceiling Cassette Models,
Unidirectional Cassette Models for High Ceilings, Ceiling Suspended Models, Wall Models
Please refer to
Setting the Wind Direction and Stopping Flap Swing.
TD831143-00̲W-3WAY.indb 8
TD831143-00̲W-3WAY.indb 8
2008/12/01 10:26:22
2008/12/01 10:26:22
Содержание SPW-C0705DZH8
Страница 2: ...i ...
Страница 3: ...ii ...
Страница 52: ...2 42 MEMO ...
Страница 158: ...3 106 MEMO ...
Страница 528: ...4 370 MEMO ...
Страница 546: ...6 Electrical Data 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 Electric Wiring Diagram SPW C0705 0905 1155DZH8 1 Outdoor Unit ...
Страница 547: ...1 2 3 4 5 6 7 8 6 Electrical Data 1 2 3 4 5 6 7 8 Schematic Diagram SPW C0705 0905 1155DZH8 1 Outdoor Unit ...
Страница 548: ...6 Electrical Data 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 2 Electric Wiring Diagram SPW C1305 1405DZH8 1 Outdoor Unit ...
Страница 549: ...1 2 3 4 5 6 7 8 6 Electrical Data 1 2 3 4 5 6 7 8 Schematic Diagram SPW C1305 1405DZH8 1 Outdoor Unit ...
Страница 552: ...6 8 Electrical Data 1 2 3 4 5 6 7 8 2 Indoor Unit 1 2 Electric Wiring Diagram SPW XM075 095 125 165 185XH ...
Страница 554: ...6 10 Electrical Data 1 2 3 4 5 6 7 8 2 Indoor Unit Schematic Diagram SPW SR74 94 124 164 184 254GXH56 A B ...
Страница 555: ...6 11 Electrical Data 1 2 3 4 5 6 7 8 2 Indoor Unit 3 Electric Wiring Diagram SPW ADR74 94 124GXH56 A B ...
Страница 556: ...6 12 Electrical Data 1 2 3 4 5 6 7 8 2 Indoor Unit Schematic Diagram SPW ADR74 94 124GXH56 A B ...
Страница 558: ...6 14 Electrical Data 1 2 3 4 5 6 7 8 2 Indoor Unit Schematic Diagram SPW LDR94 124 164 184 254GXH56 A B ...
Страница 560: ...6 16 Electrical Data 1 2 3 4 5 6 7 8 2 Indoor Unit Schematic Diagram SPW KR74 94 124 164 184GXH56 A B ...
Страница 562: ...6 18 Electrical Data 1 2 3 4 5 6 7 8 2 Indoor Unit Schematic Diagram SPW KR254GXH56 A B ...
Страница 563: ...6 19 Electrical Data 1 2 3 4 5 6 7 8 2 Indoor Unit 5 3 Electric Wiring Diagram SPW K075 095 125XH ...
Страница 569: ...6 25 Electrical Data 1 2 3 4 5 6 7 8 2 Indoor Unit Schematic Diagram SPW U075 095 125 165 185 255 365 485 605XH ...
Страница 572: ...6 28 Electrical Data 1 2 3 4 5 6 7 8 2 Indoor Unit 7 4 Electric Wiring Diagram SPW US075 095 125 165 185XH ...
Страница 573: ...6 29 Electrical Data 1 2 3 4 5 6 7 8 2 Indoor Unit Schematic Diagram SPW US075 095 125 165 185XH ...
Страница 575: ...6 31 Electrical Data 1 2 3 4 5 6 7 8 2 Indoor Unit Schematic Diagram SPW DR254GXH56 A B ...
Страница 577: ...6 33 Electrical Data 1 2 3 4 5 6 7 8 2 Indoor Unit Schematic Diagram SPW DR364GXH56 A B ...
Страница 579: ...6 35 Electrical Data 1 2 3 4 5 6 7 8 2 Indoor Unit Schematic Diagram SPW DR484GXH56 A B ...
Страница 581: ...6 37 Electrical Data 1 2 3 4 5 6 7 8 2 Indoor Unit Schematic Diagram SPW DR764GXH56 A B ...
Страница 583: ...6 39 Electrical Data 1 2 3 4 5 6 7 8 2 Indoor Unit Schematic Diagram SPW DR964GXH56 A B ...
Страница 585: ...6 41 Electrical Data 1 2 3 4 5 6 7 8 2 Indoor Unit Schematic Diagram SPW FR74 94 124 164 184 254GXH56 A B ...
Страница 587: ...6 43 Electrical Data 1 2 3 4 5 6 7 8 2 Indoor Unit Schematic Diagram SPW FMR74 94 124 164 184 254GXH56 A B ...
Страница 588: ...6 44 Electrical Data 1 2 3 4 5 6 7 8 2 Indoor Unit 11 Electric Wiring Diagram SPW GU055 075 105XH ...
Страница 589: ...6 45 Electrical Data 1 2 3 4 5 6 7 8 2 Indoor Unit Schematic Diagram SPW GU055 075 105XH ...
Страница 590: ...6 46 MEMO ...
Страница 702: ...8 96 MEMO ...
Страница 703: ...SANYO Electric Co Ltd Printed in Japan 200812B DC ...