PLC-WXU10
22
Power Source Troubleshooting:
No Power Source
after turning on
Replace AC
socket
Replace power
board or reinstall
Replace keypad
and FPC
Replace power
board
Replace
mainboard
OK
OK
OK
OK
NG
NG
NG
NG
Check 12 pin
Power output
Check
Safety Switch
Check AC socket and
connector
Check LED and keypad
FPC
Fan failure after
turning on
Reconnect fan
Replace fan
Replace
Mainboard
NG
NG
NG
OK
OK
Check
Mainboard
Check
Fan
Check fan
connection
Check
Fuse
OK
Replace fuse
NG
Содержание PLC-WXU10B
Страница 7: ...PLC WXU10 4 1 3 PLC WXU10 System Block Diagram ...
Страница 17: ...PLC WXU10 14 Step Figure Description 9 Remove the screws as shown 10 Remove the housing mylar ...
Страница 20: ...PLC WXU10 17 Step Figure Description 15 Remove the cube blower module 16 Loosen the screws S06 to remove fans ...
Страница 40: ...PLC WXU10 37 6 1 Mechanical Drawing M15 mylar 2 M12 ...
Страница 41: ...PLC WXU10 38 6 2 Other drawing ...
Страница 42: ...PLC WXU10 39 Projection Lens Assy L02 W07 ...
Страница 43: ...PLC WXU10 40 W08 is the UV lens which is used to detect the temperature of panel W08 ...
Страница 51: ......
Страница 52: ... KJ3A Jan 2008 DC 300 Printed in Japan SANYO Electric Co Ltd ...