PLC-HF10000L Expand Serial Command Functional Specifications
54/105
8.9.39 CF_CMMENU Command
Command
“CF_CMMENU_%1” [CR]
%1
“ON” ---------------------- Display Advanced color matching menu
“OFF” --------------------- Set Advanced color matching menu undisplayed.
Details
Set Advanced color matching menu displayed or undisplayed.
(Available only in the normal Power ON status)
Acceptable
“000” [CR]
Response
Unacceptable
“Error Code” [CR]
8.9.40 CF_HDMISETUP Command
Command
“CF_HDMISETUP_%1” [CR]
%1
“NORMAL” ---------------------- Set to Normal
“ENHANCED” ------------------ Set to Enhanced
Details
Set status of HDMI setup. (Available only in the normal Power ON status)
The status set by this command is stored in EEPROM and the setting remains
effective after the power is turned to ALL OFF status.
Acceptable
“000” [CR]
Response
Unacceptable
“Error Code” [CR]
8.9.41 CF_LOGO Command
Command “CF_LOGO_%1_%2” [CR]
%1
“0000 – 9999” ------------- Directly set Logo PIN code
%2
“OFF” ---------------------------Cancel Logo display
“DFLT” ------------------------- Select Logo of Factory Default
“USER” ------------------------ Select User
“UP” ----------- The same operation as pressing Up key or Left key
“DN” -----------The same operation as pressing Down key or Right key
Details
Set Logo mode. (Available only in the normal Power ON status)
The status set by this command is stored in EEPROM and setting remains
effective even after the power is turned to ALL OFF status.
Set Logo PIN code in %1.
When Logo Lock is enabled:
PIN code is matched ------------------------- Command is valid (Acceptable)
PIN code is mismatched-------------------- Command is invalid (Error code “102”)
PIN code is beyond %1 available range ----- Command is invalid (Error code”?”)
When Logo Lock is disabled:
PIN code is within %1 available range ------- Command is valid (Acceptable)
PIN code is out of %1 available range ------- Command is invalid (Error code “?”)
Note: When Logo Lock is enabled, matching Logo PIN code switches Logo but
Logo Lock is not cancelled (Lock status is kept).
*When
%
2=”USER” is received, error code “101” is returned, in the case of
Capture non-practice.
Acceptable
“000” [CR]
Response
Unacceptable “Error Code” [CR]