PLC-HF10000L Expand Serial Command Functional Specifications
72/105
9.6
Video Status Read Command
9.6.1 CR_SERSYS Command
Command “CR_SERSYS” [CR]
Details
Get currently selected signal.
Value only when Input is video. (Invalid when Input is computer)
Acceptable
“000_%1” [CR]
%1
“1080PSF/24” ------- 1080psf 24Hz
“1080P60” ----------- 1080p 60Hz
“1080P50” ----------- 1080p 50Hz
“1080P30” ----------- 1080p 30Hz
“1080P25” ----------- 1080p 25Hz
“1080P24” ----------- 1080p 24Hz
“1080I60”--------------- 1080i 60Hz / 1080psf 30Hz
“1080I50” -------------- 1080i 50Hz / 1080psf 25Hz
“1035I” ----------------- 1035i
“720P60” --------------- 720p 60Hz
“720P50” --------------- 720p 50Hz
“575P” ----------------- 575p
“480P” ------------------ 480p
“575I” ------------- 575i (includes composite signal such as PAL)
“480I” -------------480i (includes composite signal such as NTSC)
“NO_SIGNAL” --------------- There is no signal
*When 1080psf30 or 1080psf25 is inputted in System Auto,
parameter same as 1080i60/1080i50 is returned.
Response
Unacceptable “?” [CR]