PLC-HF10000L Expand Serial Command Functional Specifications
89/105
9.10.15 CR_PJLOCMENU Command
Command “CR_PJLOCKMENU” [CR]
Details
Get ON/OFF setting status of PIN code lock on menu
Acceptable
“000_%1” [CR]
%1
“ON1” -------------------- PIN code lock ON 1 is set on the menu
“ON2” -------------------- PIN code lock ON 2 is set on the menu
“OFF” -------------------- PIN code lock OFF is set on the menu
Response
Unacceptable “Error Code” [CR]
9.10.16 CR_FILH Command
Command “CR_FILH” [CR]
Details
Get Filter used time
Acceptable
“000_%1” [CR]
%1
“00000 - 99999”
Response
Unacceptable “Error Code” [CR]
9.10.17 CR_FILCOND Command
Command “CR_FILCOND” [CR]
Details
Get status of filter clog
Acceptable
“000_%1” [CR]
%1
“CLOG” = Filter is clogged
“WARN” = Filter is nearly clogged
“CLEAN” = Filter is not clogged
Response
Unacceptable “Error Code” [CR]
9.10.18 CR_FILREPL Command
Command “CR_FILREPL” [CR]
Details
Get status of Filter cleaning / replacement time
Acceptable
“000_%1” [CR]
%1
“1Y”-------Filter Exchange time is over value of Filter Message.
“1N”--Filter Exchange time is not over value of Filter Message.
Response
Unacceptable “Error Code” [CR]
9.10.19 CR_FILTIMER Command
Command “CR_FILTIMER” [CR]
Details
Get time to display Filter cleaning / replacement warning on screen
Acceptable
“000_%1” [CR]
%1
“00400” ---------------------- Display massage by 400h used.
“00700” ---------------------- Display massage by 700h used.
“01000” ---------------------- Display massage by 1000h used.
“OFF” ---------------------- Off(Warning display is not displayed)
Response