PLC-HF10000L Expand Serial Command Functional Specifications
65/105
9.4
Image Status Read Commands
9.4.1 CR_CONT Command
Command “CR_CONT” [CR]
Details
Get user controlled value of Contrast
Acceptable
“000_%1” [CR]
%1
“000” – “063”
Response
Unacceptable “?” [CR]
9.4.2 CR_BRIGHT Command
Command “CR_BRIGHT” [CR]
Details
Get user controlled value of Brightness
Acceptable
“000_%1” [CR]
%1
“000” – “063”
Response
Unacceptable “?” [CR]
9.4.3 CR_COLOR Command
Command
“CR_COLOR” [CR]
Details
Get user controlled value of Color
Acceptable
“000_%1” [CR]
%1
“000” – “063”
Response
Unacceptable
“Error Code” [CR] -----------When command is invalid in the given
condition (such as being selected input)
“?” [CR] --------- When unknown command is received
9.4.4 CR_TINT Command
Command
“CR_TINT” CR]
Details
Get user controlled value of Tint
Acceptable
“000_%1” [CR]
%1
“000” – “063”
Response
Unacceptable
“Error Code” [CR] -----------When command is invalid in the given
condition (such as being selected input)
“?” [CR] --------- When unknown command is received
9.4.5 CR_APCTRL Command
Command
“CR_APCTRL” [CR]
Details
Get setting status of Auto Picture Control
Acceptable
“000_%1” [CR]
%1
“L1” ------------------ Operate Auto Picture Control with Level1
“L2” ------------------ Operate Auto Picture Control with Level2
“OFF” --------------- Set Auto Picture Control OFF
Response
Unacceptable
“?” [CR]