PLC-HF10000L Expand Serial Command Functional Specifications
36/105
8.7.3 CF_KEYSTONE Command
Command “CF_KEYSTONE _%1” [CR]
%1
“UP” ------------- Correct Keystone distortion to reduce upper part of image
“FUP” ----------- Correct Keystone distortion to reduce upper part
“DN” ------------- Correct Keystone distortion to reduce lower part of image
“FDN” ----------- Correct Keystone distortion to reduce lower part largely
“LEFT” ---------- Correct Keystone distortion to reduce left part of image
“FLFT” ---------- Correct Keystone distortion to reduce left part largely
“RIGHT” -------- Correct Keystone distortion to reduce right part of image
“FRGT” --------- Correct Keystone distortion to reduce right part largely
“RST” ------------ Return the setting of Keystone to default.
Details
Change level of Keystone distortion correction (Available only in the normal Power
ON status).
When reached the limit of the correction level, projector accepts the command but
does not execute it.
Receiving this command immediately invokes the operation.
When trying to set the value beyond available range, error code “201” is returned
and the operation is not executed.
Example 1: When the correction level of the right part has reached its upper limit
and then the command “RIGHT” is received
Example 2: When the upper part correction allows only another step, and then the
command “FUP” is received.
Acceptable
“000” [CR]
Response
Unacceptable “Error Code” [CR]
8.7.4 CF_CORNER-UL Command
Command “CF_CORNER-UL_%1”[CR]
%1
“UP” ------------ Correct the horizontal line of image upwards
“DN” ------------ Correct the horizontal line of image downwards
“LEFT” --------- Correct the vertical line of image to the left
“RIGHT” ------- Correct the vertical line of image to the right
Details
Correct the top-left corner of the image.
(Available in normal Power ON status only)
The correction starts with the first command received
Projector returns error code “”101 and no operation is made when exceeding the
correction limit.
Acceptable
“000” [CR]
Response
Unacceptable “Error Code” [CR]
8.7.5 CF_CORNER-UR Command
Command “CF_CORNER-UR_%1”[CR]
%1
“UP” ------------ Correct the horizontal line of image upwards
“DN” ------------ Correct the horizontal line of image downwards
“LEFT” --------- Correct the vertical line of image to the left
“RIGHT” ------- Correct the vertical line of image to the right
Details
Correct the top-right corner of the image.
(Available in normal Power ON status only)
The correction starts with the first command received
Projector returns error code “”101 and no operation is made when exceeding the
correction limit.
Acceptable
“000” [CR]
Response
Unacceptable “Error Code” [CR]