PLC-HF10000L Expand Serial Command Functional Specifications
56/105
8.9.45 CF_P-MANE Command
Command “CF_P-MANE_%1” [CR]
%1
“OFF” ---------------------------------- Set Power Management to Off
“READY” ----------------------------- Set Power Management to Ready
“SHUTDOWN” --------------------- Set Power Management to Shut Down mode
“UP” ----------- The same operation as pressing Up key or Left key
“DN” -----------The same operation as pressing Down key or Right key
Details
Set/Cancel Power Management. (Valid only when in the normal Power ON status.)
The status set by this command is stored in EEPROM and the setting remains
effective after the power is turned to ALL OFF status.
Acceptable
“000” [CR]
Response
Unacceptable “Error Code” [CR]
8.9.46 CF_P-MANETIME Command
Command “CF_P-MANETIME_%1” [CR]
%1
“01” - ”30” ----------------------- Directly specify setting time by the minute
“UP” ----------- Increment value by 1 (Switched in 01
→
02
→
---
→
30
→
01 order)
“DN” ---------- Decrement value by 1 (Switched in 30
→
29
→
---
→
01
→
30 order)
Details
Set time of Power Management time (Available only in the normal Power ON
status). The status set by this command is stored in EEPROM and setting remains
effective even after the power is turned to ALL OFF status.
Acceptable
“000” [CR]
Response
Unacceptable “Error Code” [CR]
8.9.47 CF_ON-STA Command
Command “CF_ON-STA_%1” [CR]
%1
“ON” --------------------------- Set Direct on active.
“OFF” ------------------------- Set Direct on inactive.
“UP” ----------- The same operation as pressing Up key or Left key
“DN” -----------The same operation as pressing Down key or Right key
*”UP” and “DN” are exactly same operation.
Details
Set/Cancel Direct Power On (Only valid when it is in the normal Power ON status)
The status set by this command is stored in EEPROM and the setting remains
effective after the power is turned to ALL OFF status.
Acceptable
“000” [CR]
Response
Unacceptable “Error Code” [CR]