PLC-HF10000L Expand Serial Command Functional Specifications
50/105
8.9.23 CF_BLENDTESTPAT Command
Command
“CF_BLENDTESTPAT_%1” [CR]
%1
“ON” ---------------------- Set to On
“OFF” -------------------- Set to Off
Details
Set Test pattern of Edge blending.(Available only in the normal Power ON status)
The status set by this command is stored in EEPROM and setting remains
effective even after the power is turned to ALL OFF status.
Acceptable
“000” [CR]
Response
Unacceptable
“Error Code” [CR]
8.9.24 CF_BLENDRST Command
Command
“CF_BLENDRST_%1” [CR]
%1
“RST” ---------------------- Reset current setting status
Details
Reset current setting status of Edge blending.
(Available only in the normal Power ON status)
Acceptable
“000” [CR]
Response
Unacceptable
“Error Code” [CR]
8.9.25 CF_BLENDMENUOFF Command
Command
“CF_BLENDMENUOFF_%1” [CR]
%1
“SET” ----------------------
Temporarily
hide Edge blending menu and edge line
“RST” ---------------------- Display Edge blending menu and edge line
Details
Set Menu off function of Edge blending.
(Available only in the normal Power ON status)
Acceptable
“000” [CR]
Response
Unacceptable
“Error Code” [CR]
8.9.26 CF_BLENDMENU Command
Command
“CF_BLENDMENU_%1” [CR]
%1
“ON” ---------------------- Display Edge blending menu and edge line.
“OFF” --------------------- Set Edge blending menu and edge line undisplayed.
Details
Set Edge blending menu and edge line displayed or undisplayed.
(Available only in the normal Power ON status)
Acceptable
“000” [CR]
Response
Unacceptable
“Error Code” [CR]
8.9.27 CF_COLORMATCHING Command
Command
“CF_COLORMATCHING_%1” [CR]
%1
“ON” ---------------------- Set to On
“OFF” -------------------- Set to Off
Details
Set status of Color matching. (Available only in the normal Power ON status)
The status set by this command is stored in EEPROM and setting remains
effective even after the power is turned to ALL OFF status.
Acceptable
“000” [CR]
Response
Unacceptable
“Error Code” [CR]