− 20 −
EMC Directive, RoHS
Directive
IEC61326 (EMC). EN50581 (RoHS)
Accessories
Instruction manual, test leads (TL-5k)
Red/Black/Green, carrying case (C-MG5k),
“C”-size alkaline batteries x 8
TL-5k contents
TL-5K-R : 3 m LINE lead (Red) Removable type
TL-5K-B : 3 m EARTH (ground) lead (Black)
TL-5K-G : 3 m GUARD lead (Green)
TL-5K-A : Alligator clip
TL-5K-P : Test probe
TL-5K-H : Hook probe
Optional accessory
TL-5K-15 : 15 m LINE lead (Red), Removable type
Current consumption (typical value at 12 V of supply voltage)
Function
250 V
500 V
1000 V 2500 V 5000 V AC/DC V
Output at
short-circuit
450 mA
45 mA
Output at
rated current
750 mA
/0.09 MΩ
500 mA
/0.18 MΩ
700 mA
/0.36 MΩ
1200 mA
/0.9 MΩ
1500 mA
/1.8 MΩ
Output at
open-circuit 10 mA
10 mA
30 mA
50 mA 100 mA
Stand-by
45 mA
Backlight on
60 mA increases
Continuous operation time : Approx. 25 hours with 5000 V function
and 100 MΩ load.
8-2 Measuring Ranges and Accuracies
Accuracy-guaranteed temperature/humidity ranges : 23 ±5 °C, no
more than 80 %RH (without condensation)
rdg : Reading. dgt : Lowest digit.
ACV/DCV
Measurement range
Resolution
Accuracy
30-1000 V (50/60 Hz)
1 V
±(2.0 %rdg + 3 dgt)
±30-±1000 V DC
Accuracy-guaranteed frequencies : 50/60 Hz, input impedance
approx. 100 MΩ