− 19 −
[8] SPECIFICATIONS
8-1 General Specifications
AC sensing
Average value
LCD
1200 counts
Bar graph : 36 points
DAR/PI value : 9.99
Timer : 99 : 59 (min. : sec.)
Sampling rate
Approx. 3 times/sec.
Overload indication
V function : “OL” displayed with buzzer beep
Insulation function : "OL" displayed
Range selection
Auto range only
Polarity switching
Auto switching (only “−” is displayed)
Battery Monitor
4-step indication (see
4-7
)
blinks at about 7.5 V or less (accuracy
no longer guaranteed)
Environmental
condition
Altitude 2000 m or below, indoor use, pollution
degree II
Operating
temperature
/
humidity
0-40 ºC, max. relative humidity 85 % (no
condensation)
Storage temperature/
humidity
-10-60 ºC, max. relative humidity 90 %, no
condensation (with batteries removed)
(Batteries should be removed before storage
for a long period.)
Power supply
“C”-size alkaline battery 1.5 V (LR14) x 8
Auto Power Off
Power OFF in about 10 minutes after last
operation.
Max. power
consumption
Approx. 18 VA (measurement at 5000 V/
approx. 1.8 MΩ)
Measurement count 1000 times (5000 V/5 MΩ measurement, 5 sec.
ON/25 sec. OFF)
Dimensions & mass
188(
H
) x 225(
W
) x 97(
D
) mm, approx. 1750 g
(batteries included)
Year of production
Initial 2 digits of the main unit serial No.
indicates the last two digits of year (20**).
IP class
IP54
Safety standards
IEC61010-1 CAT.III 1000 V/IV 600 V
IEC61010-2-030, IEC61010-031. IEC61557-1 & 2