3.9.15.
Filter Reactor Ratings
3.9.15.1.
Class 2T and 4T
To use the following table, refer to Figure 9.
ES PART
No.
INDUCTANCE
RATINGS
LOSSES
at Inom TYPE
SIZE
SLOT WEIGHT
TERMINAL
TYPE
CABLE
SECT.
mH
A
W
L
P
H E G
mm
kg
mm
2
IM0128604
2.6
12.5
25
\
150 120 160 125 71
7x14
7
Cable Lug
2,5
IM0128644
2.0
16.5
35
B
180 120 190 150 67
7x14
8
Cable Lug
4
IM0128684
1.1
30
50
B
180 130 190 150 82
7x14
11
Cable Lug
10
IM0128724
0.90
41
90
B
240 140 245 200 87
7x14
15
Cable Lug
10
IM0128744
0.60
60
110
B
240 150 245 200 97
7x14
16
Cable Lug
25
IM0128764
0.45
80
120
B
240 160 245 200 107
7x14
18
Cable Lug
25
IM0128804
0.35
103
135
B
240 180 245 200 122
7x14
24
Cable Lug
50
IM0128844
0.25
135
160
B
240 190 245 200 122
7x14
26
Cable Lug
50
IM0128884
0.175
200
220
A
300 210 300 250 118
9x24
43
Bar 30mm
hole 9mm
120
IM0128924
0.135
320
310
A
360 220 320 325 125
9x24
64
Bar 30mm
hole 9mm
240
IM0128934
0.100
440
810
A
360 250 330 325 160
9x24
70
Bar 40mm
hole 11mm
2x120
IM0128964
0.080
565
900
A
360 290 350 250 200 Hole 12
85
Bar 40mm
hole 11mm
2x185
IM0128965
0.060
700
1270
A
420 290 410 300 200 12x24
120
Bar 40mm
hole 11mm
2x240
IM0128974
0.060
900
730
A
420 330 415 300 200 12x24
136
Bar 50mm
3x240
IM0128984
0.040 1200
940
A
450 340 525 300 200 15x25
182
Bar 50mm
4x240
IM0128988
0.028 1700
2080
A
510 435 600 300 250 12x24
281
Bar 60mm
2x3x185
IM0128994
0.020 1950
1980
A
510 420 600 300 250 12x24
260
Bar 60mm
2x3x240
Table 3: Filter reactors (class 2T and 4T)