SINUS PENTA
GUIDE TO THE
REGENERATIVE APPLICATION
108/
150
P535a/b/c Phase R/S/T Voltage RMS Offset
P535a/b/c
Range
–2048
+2047
47.4 V
Default
0
0 V
Level
ENGINEERING
Address
970/971/972
Function
Register for the correction of the voltage offset error.
P536a/b/c Phase R/S/T Current RMS Offset
P536a/b/c
Range
–2048
+2047
0.3%
Default
0%
0%
Level
ENGINEERING
Address
973/974/975
Function
Register for the correction of the current offset error.
P537a/b/c Phase R/S/T Active Power Offset
P537a/b/c
Range
–2048
+2047
0.015%
Default
0
0%
Level
ENGINEERING
Address
976/977/978
Function
Register for the correction of the active power offset error.
P538a/b/c Phase R/S/T Reactive Power Offset
P538a/b/c
Range
–2048
+2047
0.015%
Default
0
0%
Level
ENGINEERING
Address
979/980/981
Function
Register for the correction of the reactive power offset error.