GUIDE TO THE
REGENERATIVE APPLICATION
SINUS PENTA
25/
150
3.4.
Specifications for the Regenerative Drive
3.4.1. Regenerative Drive Ratings
– 2T Voltage Class
SIZE
REGENERATI
VE SINUS
PENTA
MODEL
REGENERATIVE
DRIVE
DELIVERABLE
CURRENT
RATED POWER OF THE
REGENERATIVE DRIVE
MAXIMUM POWER OF THE
REGENERATIVE DRIVE
REGENERATIVE
DRIVE LOSSES
Inom
Imax
Power Supply (±10%)
Power Supply (±10%)
220Vac
230Vac
220Vac
230Vac
A
A
kW
kW
kW
kW
kW
S05
0007
12.5
13.5
4.1
4.3
4.5
4.7
0.16
0008
15
16
5.0
5.2
5.3
5.6
0.17
0010
17
19
5.6
5.9
6.3
6.6
0.18
0013
19
21
6.3
6.6
7.0
7.3
0.19
0015
23
25
7.7
8.1
8.4
8.8
0.21
0016
27
30
9.0
9.4
10.1
10.5
0.23
0020
30
36
10.0
10.5
12.1
12.6
0.25
S12
0023
38
42
12.7
13.3
14.1
14.7
0.39
0033
51
56
17.0
17.8
18.7
19.6
0.51
0037
60
72
20.0
20.9
24.1
25.2
0.60
S15
0040
72
80
24.0
25.1
25.1
26.2
0.64
0049
75
96
24.9
26.1
32.1
33.6
0.75
S20
0060
88
112
29.3
30.7
37.5
39.3
0.83
0067
103
118
34.3
35.9
39.4
41.3
0.99
0074
120
144
40.1
41.9
48.3
50.5
1.05
0086
135
155
45.1
47.2
51.9
54.3
1.16
S30
0113
180
200
60.0
62.8
66.8
69.9
1.70
0129
195
215
65.0
68.0
71.8
75.2
1.81
0150
200
270
66.6
69.7
90.5
94.7
1.95
0162
210
290
69.8
73.0
97.2
101.7
2.18
S41
0180
300
340
102.8
107.5
114.6
119.9
1.86
0202
345
420
118.2
123.6
141.6
148.1
2.30
0217
375
460
128.5
134.3
155.1
162.3
2.43
0260
425
560
145.6
152.2
189.1
197.8
2.75
S51
0313
480
600
161.3
168.7
202.4
211.7
3.15
0367
550
680
184.9
193.5
229.5
240.0
3.47
0402
680
850
228.5
239.1
286.8
300.0
4.40
S60
0457
720
880
241.0
252.2
295.8
309.5
5.60
0524
800
960
267.6
280.1
322.4
337.4
6.40
Legend:
Inom
= Continuous rated current of the regenerative drive.
Imax
= Max. current that can be delivered by the drive for 120sec every 20min up to S30, and for 60sec
every 10min for S41 and greater.
NOTE
Output power is intended for the power supply of one or more SINUS PENTA
drives. Any other applications must be authorized by Elettronica Santerno.