![Samyung BNW - 50 Скачать руководство пользователя страница 43](http://html1.mh-extra.com/html/samyung/bnw-50/bnw-50_user-manual_3800255043.webp)
43
2
BNWAS does not turn on
Check the AC or DC fuse..
Check the power supply of AC input power(220V) and DC input
power (24V)
Check the power cable’s connection.
3
Reset function does not
work.
Check the interface socket [RES1/LOW] of BNW-51. Socket power (pin
number 9~ 10)
(It should be 0V only when reset button is pressed or movement
was detected).
Movement detect: Socket should be 0V only when the red lamp is
lighted.
When power supply stays at 0V.
1. Set the BNWAS as OFF mode.(press OFF on the display).
2. Install only 1 reset unit in the terminal pin number 9.
3. Set BNWAS as MANUAL mode.
4. Check if the visual alarm activates after 3 minutes
5. Press the reset button to check if the alarm resets.
6. Set BNWAS as OFF mode.
7. Install only 1 motion sensor in the terminal pin number 9.
8. Set BNWAS as Manual mode and do not move.
9. Check if the visual alarm activates after 3 minutes.
10. Check if the alarm resets when the movement is made around.
11. Install both reset unit and motion sensor and follow the steps
above to check.
4
Visual alarm, 1
st
stage~
3
rd
stage audible alarm
are not operating, yet is
shown as activated on the
display.
Check the cable.
Check the DC24V power supply on the terminal of the alarm unit
(BNW-53)