Chapter 4    BNW-50 (DISPLAY UNIT) 

- Rated input voltage DC 24V 

 

 

(NOTE)  Program  version  may  change  without  notice  for 

performance improvement. 

 

4.1    BUTTONS   

Bridge Navigational Watch Alarm System

RES

EMG 

ESC

MENU

BNW-50

 

 

Button 

Function 

Note 

EMG 

 

Pressing  down  this  button  for  2  seconds  will  activate  the  emergency 
call function. 

By pressing down for another 2 seconds will deactivate the alarm. 

EMERGENCY 

Call 

MENU

 

Used  to  get  into  the  menu  function  and  message  will  appear  if  you 
wish to save after the setup. 

MENU 

ESC

 

Brings you back to the previous page. 

ESCAPE 

 

Enter key allows you to select the menu or the individual menu. 

ENTER 

 

Used to verify the password. 

CHECK 

!

Содержание BNW - 50

Страница 1: ...1 USER MANUAL USER MANUAL USER MANUAL USER MANUAL BNW 50 Bridge Navigational Watch Alarm System Rev M00 0481 00...

Страница 2: ...2...

Страница 3: ...duced under protected environment of electrostatic discharge This is because the most of the semiconductor equipment used in the PCB can be damaged easily by the electrostatic discharge You must preve...

Страница 4: ...1 SEQUENCE OF ALARM 10 2 3 2 Visual Alarm 11 2 3 3 1 stage Audible Alarm 11 2 3 4 2 stage Audible Alarm 11 2 3 5 3 stage Audible Alarm 11 2 3 6 Emergency Call 11 CHAPTER 3 PRODUCT SPECIFICATION 12 3 1...

Страница 5: ...Y 25 4 5 1 DORMANT PERIOD 25 4 5 2 Visual alarm 25 4 5 3 1st stage audible alarm 26 4 5 4 2nd stage audible alarm 26 4 5 5 3rd stage audible alarm 27 4 5 6 Emergency call 27 4 5 7 Failure indicator 28...

Страница 6: ...SUAL ALARM VIS 34 6 13 1ST STAGE AUDIBLE ALARM AUD 34 6 14 2ND STAGE AUDIBLE ALARM ALARM A G 35 6 15 3RD STAGE AUDIBLE ALARM ALARM A G 36 CHAPTER 7 INSTALLATION CAUTION 37 7 1 GENERAL 37 7 2 LOCATION...

Страница 7: ...FLUSH TYPE STANDARD 46 12 4 BNW 53 FLUSH TYPE STANDARD 46 12 5 MONTION SENSOR STANDARD 47 12 6 BNW 52 DESK TYPE OPTION 47 12 7 BNW 52 WATERTIGHT TYPE OPTION 48 12 8 BNW 53 DESK TYPE OPTION 48 12 9 CA...

Страница 8: ...FLUSH TYPE OUTLINE DRAWING 57 13 9 BNW 52W WATERTIGHT TYPE OUTLINE DRAWING 58 13 10 BNW B FLUSH TYPE OUTLINE DRAWING BNW 52 53 59 13 11 MOTION SENSOR DND 300M OUTLINE DRAWING 60 CHAPTER 14 WARRANTY I...

Страница 9: ...dard requirement Existing Vessel requires to install the equipment before the first inspection after the below date Existing passenger ship and Vessels under 3000t 1st JULY 2012 Existing vessels over...

Страница 10: ...ircumstances 2 1 3 AUTO Mode On this mode BNWAS system operates automatically once vessel s heading or the track control system when signal has been inputted is operating refer to 6 5 input terminal f...

Страница 11: ...captain s cabin 2nd stage audible alarm is triggered if timer is not RESET within the 15 seconds after 1st stage audible alarm is triggered 1st stage and 2nd stage audible alarms are both triggered a...

Страница 12: ...A data Reset alarm etc Inputting DC12V power supply and reset of motion sensor and reset unit Outputting the alarm signal for reset and alarm unit Outputting the NMEA data for blackbox VDR Outputting...

Страница 13: ...TION METHOD Quad element PIR and microwave pulse Doppler MW frequency 10 525GHz SIZE 115 x 61 x 37 5 mm H x W x D WEIGHT 120g BRACKET EXCLUDED OPERATION TEMPERATURE 15 C 55 C DETECTIVE ANGLE 120 150 D...

Страница 14: ...able 4 2 Alarm unit installation accessory BNW 53 A 7 SET Flush type 5 Motion sensor installation accessory included DND 300M 2 SET Additional installation available 3 6 2 BNW 50 OPTION SPECIFICATION...

Страница 15: ...Note EMG Pressing down this button for 2 seconds will activate the emergency call function By pressing down for another 2 seconds will deactivate the alarm EMERGENCY Call MENU Used to get into the men...

Страница 16: ...to the selected function or change the setting Control key 4 2 SETTING PASSWORD Once power is connected to the equipment this screen will show Captain may set the password that he should only know If...

Страница 17: ...herefore adjusting the setting can be only done by authorized person captain Checking the password In order to get to the menu password is required When MENU is pressed CHECK MASTER PASSWORD appears t...

Страница 18: ...etting alarm mode OFF Mode BNW 50 does not operate under this mode On the operational status it shows MANUAL for MODE and OFF for ALARM STATE MANUAL Mode Under this mode BNW 50 always operates On the...

Страница 19: ...or ALARM STATE Setting dormant period and the period between the second and third alarm You can control the Dormant period 3 12minutes and the period between the second and third alarm 90 180 seconds...

Страница 20: ...andard reset terminal Move the cursor to the wanted menu then press then you may decide the use of additional reset unit Changing the period of the 1st stage audible alarm s warning alert You can chan...

Страница 21: ...sual alarm and 1st stage audible alarm Activate ON 2nd stage audible alarm Alarm A B C Activate ON 3rd stage audible alarm Alarm D E F G Also by using the additional reset unit you can activate ON the...

Страница 22: ...unit version and figures S00 017 2011 07 12 and D0 0 017 20 11 07 12 shown on the right side means the display unit s version of the each processor unit Initialize When you wish to initialize the set...

Страница 23: ...check the visual alarm 1st stage audible alarm and other connected alarms immediately Move cursor to the test mode by using then press this will activate the alarm However when setting the additional...

Страница 24: ...data on SD card After inserting the SD card by using and check the box and save by pressing MENU BNWAS_SAMYUNGENC_VDR txt file will be created in the SD card and at the same time VDR data will be save...

Страница 25: ...he reset of the timer can be done in 3 different ways For the additional reset input using additional unit refer to 6 6 6 8 Manual way of pressing RES button from the display unit of BNW 50 Manual way...

Страница 26: ...hin 15 seconds after the 1st stage audible alarm is triggered then the timer will restart from 3 minutes 4 5 4 2nd stage audible alarm 2nd stage audible alarm will activate if timer has not been reset...

Страница 27: ...ter this the time restarts from 3 minutes 4 5 6 Emergency call By pressing the button EMG down for 2 seconds 2nd stage audible alarm will activate immediately If no actions are taken then 3rd stage au...

Страница 28: ...ower 110 220V AC or back up power 24V DC is not connected Main Power Failure or Back Up Power Failure will appear on the top of the display in red black writings Pictures below show Main Power Failure...

Страница 29: ...n Color POWER LED lights up when power is connected Red LED AUTO LED lights up when AUTO is selected from the Operational mode Green LED ERROR LED lights up when the main or the back up power is not s...

Страница 30: ...Alert interface output 28 29 PIN for machinery breakdown Interface input 30 31 PIN for activing track controller NMEA data output 32 34 PIN for blackbox VDR NMEA data reset alarm etc input 35 36 PIN...

Страница 31: ...the flush mounting for the display unit BNW 50 Connect the display unit BNW 50 with the processor unit BNW 51 with cable Z8 2M 05 provided 24V GND TXD SLD RXD IN OUT 1 2 5 4 3 DISPLAY BNW 50 BNW 51 P...

Страница 32: ...you have enough space to install the display unit 6 3 RESET SET UP RES1 LOW ALARM VIS AUD Connect the reset unit BNW 52 to the interface socket RES1 of BNW 51 Reset unit is usually installed near the...

Страница 33: ...activation input Under the AUTO mode two brackets INP INP should be in contact for BNWAS to activate 6 6 Additional reset terminal RES2 LOW You can connect additional external reset unit or the motion...

Страница 34: ...emergency call s terminal gets disconnected it will stop operating the emergency call will stop operating It is possible to connect the alarm contact signal coming from the outside with this terminal...

Страница 35: ...terminal ALARM C 2nd stage audible alarm officer s cabin 3 connection terminal ALARM D 2nd stage audible alarm officer s cabin 4 connection terminal ALARM E 3rd stage audible alarm crew s quarter s c...

Страница 36: ...l connected alarms will activate Delay setup for 2nd stage alarm s timer In large vessels the delay between the 2nd and 3rd stage alarms may be set to a longer value when installing from 90 180 second...

Страница 37: ...on the bridge giving proper look out and preferably adjacent to visual indications Means of activating the reset function shall be easily accessible from the conning position the workstation for navig...

Страница 38: ...0 150 and is not harmful to human By using the bracket attached to the sensor you may install it easily on the wall or the ceiling Input voltage 12 VDC 3V Power consumption Operating 26mA Standby 17mA...

Страница 39: ...s power cable 3 Do not install it at the back of the partition 4 Avoid installing near the heat 5 Install it on the stable and hard surface 6 Avoid installing from windy environment 7 Do not install...

Страница 40: ...technician if required Infrared ray PIR detective range adjustment Use the volume marked with PIR to adjust the detective sensitivity from 15 to 100 according to the ambulation test it is set at the m...

Страница 41: ...the 2nd stage audible alarm 6 Go to the bridge and reset all the alarms by pressing the reset button 7 Press the emergency call button for 2 seconds Check if the 3rd stage alarm is displayed after the...

Страница 42: ...ground wire Clean Use clean tissue or the soft fiber to clean the salt precipitate or dirt Do not use the chemical liquids as it may erase the letters or peel the writings on the equipment off 10 2 Fa...

Страница 43: ...only 1 reset unit in the terminal pin number 9 3 Set BNWAS as MANUAL mode 4 Check if the visual alarm activates after 3 minutes 5 Press the reset button to check if the alarm resets 6 Set BNWAS as OFF...

Страница 44: ...exceeded dormant period time A A Alert response V No alert response c c BNWAS Mode Refer to IEC 62616 3 1 1 c1 c2 c3 c1 AUT or MAN or OFF c2 Dormant period time by minutes 03 12 c3 Alert stage 1 2 or...

Страница 45: ...0050 00 3 2A 250V 30mmX6mm 5 FUSE CODE NO 527 2002 2Q 2 12 2 BNW 51 STANDARD BNW 51 Processor Unit desktop NO Item External Feature STANDARD Q ty CHK Remark BNW 51 1 Processor UNIT POWER AUTO ERROR AL...

Страница 46: ...et BNW 52 CODE NO E02 1800 00 1 BNW 52 A Reset unit installation accessory Stain piece type1 3X12 STS 2 Screw CODE NO 904 0237 01 4 BNW 52 CABLE RUBBER 3 Rubber CODE NO E02 1841 00 1 12 4 BNW 53 Flush...

Страница 47: ...Reset unit desktop NO Item External Feature STANDARD Q ty CHK Remark BNW 52 1 RESET UNIT SAMYUNG Resetunit Push button to reset Reset BNW 52 CODE NO E02 1800 00 1 BNW B Desk type bracket BNW B 2 Brack...

Страница 48: ...pe bracket installation accessory M3X6 STS304 3 Bolt CODE NO 900 0134 02 4 TYPE 1 3X12 STS 4 Screw CODE NO 904 0037 11 4 BNW 52 CABLE RUBBER 5 Rubber CODE NO E02 1841 00 1 BNW 52W Watertight reset uni...

Страница 49: ...le CODE NO 576 2002 1K C 3 LENGTH OPTION Alarm unit installation cable SMALL UL 2464 6C X 20 AWG 3 Screw CODE NO 567 2006 1K C 5 LENGTH OPTION Alarm unit installation cable LARGE CVV SB 1 25SQMM X 2C...

Страница 50: ...t Push button to reset SAMYUNG 1 PORT 1 PORT 1 PORT 1 2 PORT 1 PORT 1 PORT DC 24V Option or Local Supply System Fail Contact N O VDR AC 220V IEC61162 Track System Alarm Reset etc Contact N O RADR ECDI...

Страница 51: ...28 31 30 32 DISPLAY RESET UNIT C B A 1 2 3 4 5 6 7 4 6 5 7 3 8 DISPLAY UNIT BNW 50 ALARM UNIT OPTION 12V GND 1 2 ALARM REMOT C 1 RES 24V 24V GND 24V GND 16 14 15 17 18 BNW 52 RELAY BNW 53 2 1 ALARM G...

Страница 52: ...53 SAMYUNG SAMYUNG Assistance to bridge Assistance to bridge Alarm unit BNWAS 53 Alarm unit BNW 53 C 6 C 3 or E ALARM RES RES1 LOW MOTION SENSOR PROCESS UNIT BNW 51 Push button to reset Reset BNW 52...

Страница 53: ...unit BNW 53 Max 10 OFFICER CABINS SAMYUNG SAMYUNG C 3 TAPING Assistance to bridge Assistance to bridge BNW 53 Alarm unit BNW 53 Alarm unit DND 300M DND 300M MOTION SENSOR MOTION SENSOR C 3 C 3 TAPING...

Страница 54: ...54 13 5 BNW 50 OUTLINE DRAWING 1 A B C 126 5 1 2 3 4 B N W 5 0 ESC MENU EMG RES D E 183 1 5 6 7 93 5 1 8 9 7 6 1 8 5 4 3 2 113 5 1...

Страница 55: ...A UD LOW ALARM RES1 12 A UD 11 8 9 10 V IS R ES 1 2V G ND 14 1 3 2 4V G ND NMEA TXD 33 TXD 198 1 F C D E B ALARM ALARM ALARM ALARM ALARM 20 2 4V 19 18 16 17 G ND 2 4V 2 4V G ND 23 24 2 5 21 22 G ND G...

Страница 56: ...56 13 7 BNW 52 FLUSH TYPE OUTLINE DRAWING BNW 52 1 2 A 3 4 5 6 B C Reset unit to reset Push button SAMYUNG Reset 7 8 9 E D 29 7 1 126 1 90 1...

Страница 57: ...57 13 8 BNW 53 FLUSH TYPE OUTLINE DRAWING 1 2 A 3 4 5 6 B C SAMYUNG BNW 53 Alarm unit Assistance to bridge 126 1 7 8 9 90 1 E D 29 7 1...

Страница 58: ...58 13 9 BNW 52W WATERTIGHT TYPE OUTLINE DRAWING to reset A B 1 2 SAMYUNG 3 4 Push button Reset Reset unit BNW 52 5 6 127 1 178 1 7 8 9 C D E 22 1 175 1 92 5 1...

Страница 59: ...59 13 10 BNW B FLUSH TYPE OUTLINE DRAWING BNW 52 53 66 1 1 2 A 3 4 5 6 B C 4 M3TAP 4 3 5 35 54 1 7 8 9 76 6 1 90 1 E D 90 1 108 2 1 114 1 1 2 0 1 38 1 13 1...

Страница 60: ...60 13 11 MOTION SENSOR DND 300M OUTLINE DRAWING 1 3 2 4 A B C D E 122 8 1 5 6 7 8 9 58 1 79 1...

Страница 61: ...1 year warranty is given from the date of purchase BUT break down caused by the user s inappropriate use will be charged HEAD OFFICE A S ADDRESS 65 20 Namhang Dong 2 Ga Youngdo Gu Busan Korea COMPANY...

Страница 62: ...62...

Страница 63: ...63...

Страница 64: ...g Youngdo Gu Busan Korea 606 083 Tel 051 601 5555 6666 Fax 051 413 4446 412 6616 A S 65 20 Namhang Dong 2 Ga Youngdo Gu Busan Korea Tel 051 601 5570 5574 Fax 051 416 5515 SEOUL OFFICE Tel 02 569 6242...

Отзывы: