Chapter 7 Installation Caution
7.1 General
Follow requirements in IMO resolution MSC.128(75) concerning the installation of the BNWAS.
7.2 Location of reset unit (128/A4.1.3.1)
It shall not be possible to initiate the reset function or cancel any audible alarm from any device,
equipment or system not physically installed in areas of the bridge.
7.3 Reset installation (128/A5.1.4)
Means of activating the reset function shall only be available in positions on the bridge giving proper
look out and preferably adjacent to visual indications. Means of activating the reset function shall be
easily accessible from the conning position, the workstation for navigating and maneuvering, the
workstation for monitoring and the bridge wings.
7.4 Visual alarm (128/A5.2.2 part)
Visual alarm shall be visible from all operational positions on the bridge where the watch officer may
reasonably be expected to be stationed.
7.5 1
st
stage audible alarm (bridge) (128/A5.2.3 part)
This alarm shall be audible from all location where watch officer may reasonably be expected to be
stationed. This includes wheelhouse and the bridge wing.