![Samyung BNW - 50 Скачать руководство пользователя страница 27](http://html1.mh-extra.com/html/samyung/bnw-50/bnw-50_user-manual_3800255027.webp)
27
4.5.5 3
rd
stage audible alarm
3
rd
stage audible alarm will activate if the timer has not been reset within 90 seconds after the 2
nd
stage
audible alarm is activated. On the display, “3
RD
ALARM” will be shown under ALARM STATE and the “3
RD
ALARM” and the elapsed time “2:09” will be shown in red/black. On this status, all the alarms connected
to the BNWAS are triggered at the same time. If timer has been reset after this, the time restarts from 3
minutes.
4.5.6 Emergency call
By pressing the button
EMG
down for 2 seconds, 2
nd
stage audible alarm will activate immediately. If
no actions are taken then 3
rd
stage audible alarm will automatically activate. On the screen, “2
nd
Alarm”
will be displayed under ALARM STATE and soon “3
rd
ALARM” will be shown. “2
nd
, 3
rd
ALARM” and the
“EMERGENCY!!” will be written in black. After the emergency call function has been deactivated, then
you must go back to the previous set up status and set the timer from 3 minutes.
By pressing down the button for 2 seconds will deactivate the emergency call.