![Samwontech TEMI770 Скачать руководство пользователя страница 42](http://html1.mh-extra.com/html/samwontech/temi770/temi770_manual_3793449042.webp)
II.USERS
IM TEMI 770E_C 2nd Edition: Sep. 1. 2003. 23/40
5-6-1. INPUT
Select INPUT at the SETUP page(Figure 5-6-1) for switching the INPUT page.
■
INPUT_TEMP
Figure 5-6-2 TEMP INPUT
①
SENSOR
: Select kinds of temp sensor. (PT_1, PT_2., DCV)
②
TEMP RANGE
: Set the range of Temperature.
③
TEMP BIAS
: Bias about the temperature.
④
TEMP FILTER
: To remove the noise from the high-frequency of noise in the temp data.
⑤
SCALE
(DCV ONLY)
: As DCV sensor type, set the scale for range.
(Table 5-7) INPUT_TEMP PARAMETER
Name
Function
Valid Range
Unit
Default Value
T.SENSOR
TEMP SENSOR
PT_1, PT_2, DCV
ABS
PT_1
T.RH
TEMP RANGE HIGH
T.EU(0 ~ 100%)
T.EU
T.EU(100%)
T.RL
TEMP RANGE LOW
T.EU(0 ~ 100%)
T.EU
T.EU(0)
T.BIAS
TEMP BIAS
T.EUS(-100 ~ 100%)
T.EU
T.EUS(0%)
T.FILTER
TEMP FILTER
0 ~ 120S
ABS
0(S)
H.SCALE
TEMP HIGH SCALE
-99.9 ~ 200.0
℃
-100.0
(
℃
)
L.SCALE
TEMP LOW SCALE
-100.0 ~ 199.9
℃
200.0(
℃
)
Figure 5-6-3 INPUT HUMI