I. INSTALLATION
IM TEMI 770E_C 2nd Edition: Sep. 1. 2003. 8/15
4-2. Terminal wiring diagram
Figure 4-2-B TEMI 770-11 Type
Figure 4-2-C TEMI 770-20 Type
Figure 4-2-D TEMI550-21 Type
Figure 4-2-A TEMI 770-10 Type
Figure 4-2-E Standard I/O board and Additional I/O board
CAUTION
★
(8Ea) are not for connection terminals, these are only for install.
Avoid used those place, it might make damage to system or out of order.
CAUTION
Before carrying out wiring, turn off the power to the controller and check
that the cables to be connected are not alive with a tester or the like because
there is a possibility of electric shock. Wiring must be carried out by personnel
who have basic electrical knowledge and practical experience.
※
This shapes are depends on model.
RS232
I/O 2 LINK
SG
RTX+ RTX-
RXD TXD
RS485
SG
RTX+ RTX-
RXD TXD
RS485
I/O 2 LINK
RLY10_NC RLY10_NO COM3 RLY9_NO RLY9_NC
RLY8_NC RLY8_NO COM2
RLY7_NO RLY7_NC
COM1 RLY6 RLY5 RLY4 RLY3 RLY2 RLY1
P7
GND
P3
AOUT1+ AOUT1- AOUT2+ AOUT2-
(TEMP) (HUMI)
RET1+ RET1- RET2+ RET2-
DI_1 DI_2 DI_3 DI_4 DI_5 DI_6 DI_7 DI_8 DI_COM
Additional board does not have those parts.
*External Contact Switch
It is working
together as
“AND” condition
with RELAY 10.
100-240VAC
SUPPLY
INPUT1
INPUT2
I/O1 LINK
RS232
100~240VAC
CAUTION
★
★
★
★