SYSTEM MANAGEMENT
Loop Setting [Add – Network Communication]
Below describes how to setup Loop Setting for networked communication (LAN, WAN, Internet) between the
operating computer and controller.
From the upper menu, select [System Management] > [Loop Setting].
Click Add <
> in the tool bar.
Select a [Site].
Enter the [Loop].
Select [Network Communication] in [Communication Type].
Select whether to use or not in [Whether to use]. If unchecked, devices connected to the selected loop will not
communicate.
Set the interval of polling in [Polling Speed (ms)]. It is recommended to set to 200 ms even the optimal polling
speed may vary depending on devices.
Access controllers will communicate with the management program for data transfer in polling method. Polling
speed means the interval between data requesting polls of the SAMS Communication Server to devices.
Move to the [Network Communication] tab.