2
Volume control
0x12
0~100
3
Input source control
0x14
-
4
Screen Mode control
0x18
-
5
Screen Size control
0x19
0~255
6
PIP on/off control
0x3C
0~1
7
Auto adjustment control
0x3D
0
8
Video wall Mode control
0x5C
0~1
9
Safety Lock
0x5D
0~1
- ID should show hexadecimal value of assigned ID, but ID 0 should be 0xFF.
- Every communication will be made in hexadecimals and Checksum is the sum of all remainings.
If it exceeds two digits,for example, it is 11+FF+01+01=112, discard the number in the first digit
like below.
example)PowerOn&ID=0
Header
command
ID
DATA
Length
DATA 1
CheckSum
0xAA
0x11
1
Power
Header
command
ID
DATA
Length
DATA 1
12
0xAA
0x11
1
1
If you want to control every mechanism connected with Serial Cable regardless of its ID, set ID
part to "0xFE" and send commands. At the time, each product will follow commands but it will
not respond with ACK.
•
Power Control
•
Function
Personal Computer turns TV / Monitor power ON/OFF.
•
Get Power ON/OFF Status
Header
command
ID
DATA Length
CheckSum
0xAA
0x11
0
•
Set Power ON/OFF
Header
command
ID
DATA
Length
DATA
CheckSum
0xAA
0x11
1
Power
Power : Power code to be set on TV / Monitor
1 : Power ON
0 : Power OFF
Introduction