background image

Confidential

 

MT3204 Series Installation Manual   v1.0 

 

 

vi 

Copyright © 2018, All Rights Reserved.

 

List of Figures 

Figure 1. 

MMU View ....................................................................................................................................... 2 

Figure 2. 

MMU External Interface ................................................................................................................... 3 

Figure 3. 

Procedure to Install the MMU ....................................................................................................... 10 

Figure 4. 

MMU Arrangement_Pole Type Installation ................................................................................... 11 

Figure 5. 

MMU Arrangement_Wall Type Installation ................................................................................... 12 

Figure 6. 

MMU Arrangement_Swivelling ...................................................................................................... 13 

Figure 7. 

Transporting the MMU .................................................................................................................. 15 

Figure 8. 

Fixing Unit Bracket (1) .................................................................................................................... 16 

Figure 9. 

Fixing Unit Bracket (2) .................................................................................................................... 17 

Figure 10. 

Fixing Pole Mount Bracket-Bottom (1)........................................................................................... 18 

Figure 11. 

Fixing Pole Mount Bracket-Bottom (2)........................................................................................... 19 

Figure 12. 

Fixing Pole Mount Bracket-Bottom (3)........................................................................................... 20 

Figure 13. 

Fixing Pole Mount Bracket-Top (1) ................................................................................................. 21 

Figure 14. 

Fixing Pole Mount Bracket-Top (2) ................................................................................................. 22 

Figure 15. 

Fixing Pole Mount Bracket-Top (3) ................................................................................................. 22 

Figure 16. 

Lifting MMU & Pole Mount Bracket Assembly-Top (1) .................................................................. 23 

Figure 17. 

Lifting MMU & Pole Mount Bracket Assembly-Top (2) .................................................................. 23 

Figure 18. 

Lifting MMU & Pole Mount Bracket Assembly-Top (3) .................................................................. 24 

Figure 19. 

Fixing Pole Mount Bracket Assembly-Top (1) ................................................................................ 25 

Figure 20. 

Fixing Pole Mount Bracket Assembly-Top (2) ................................................................................ 25 

Figure 21. 

Fixing Pole Mount Bracket Assembly-Top (3) ................................................................................ 26 

Figure 22. 

Fixing Pole Mount Bracket Assembly-Top (4) ................................................................................ 26 

Figure 23. 

Fixing Pole Mount Bracket Assembly-Top (5) ................................................................................ 27 

Figure 24. 

Fixing Pole Mount Bracket Assembly-Top (6) ................................................................................ 27 

Figure 25. 

Fixing MMU on the Pole (1) ........................................................................................................... 29 

Figure 26. 

Fixing MMU on the Pole (2) ........................................................................................................... 30 

Figure 27. 

Fixing MMU on the Pole (3) ........................................................................................................... 31 

Figure 28. 

MMU Marking Dimensions ............................................................................................................ 33 

Figure 29. 

Marking_Wall Mount Bracket-Top Assembly ................................................................................ 34 

Figure 30. 

Drilling & Anchor (1) ....................................................................................................................... 35 

Figure 31. 

Drilling & Anchor (2) ....................................................................................................................... 36 

Figure 32. 

Fixing Wall Mount Bracket-Top Assembly (1) ................................................................................ 37 

Figure 33. 

Fixing Wall Mount Bracket-Top Assembly (2) ................................................................................ 37 

Figure 34. 

Assembling Wall Mount Bracket-Bottom....................................................................................... 38 

Figure 35. 

Fixing MMU .................................................................................................................................... 39 

Figure 36. 

MMU Down Tilting (1) .................................................................................................................... 42 

Figure 37. 

MMU Down Tilting (2) .................................................................................................................... 43 

Figure 38. 

MMU Down Tilting (3) .................................................................................................................... 44 

Figure 39. 

MMU Down Tilting (4) .................................................................................................................... 45 

Figure 40. 

MMU Down Tilting (5) .................................................................................................................... 45 

Figure 41. 

MMU Down Tilting (6) .................................................................................................................... 46 

Figure 42. 

Bracket Change for MMU Up Tilting (1) ......................................................................................... 48 

Figure 43. 

Bracket Change for MMU Up Tilting (2) ......................................................................................... 49 

Figure 44. 

Bracket Change for MMU Up Tilting (3) ......................................................................................... 50 

Figure 45. 

Bracket Change for MMU Up Tilting (4) ......................................................................................... 52 

Figure 46. 

Bracket Change for MMU Up Tilting (5) ......................................................................................... 53 

Figure 47. 

Lifting MMU & Pole Mount Bracket Assembly-Top (1) .................................................................. 54 

Содержание MT3204 Series

Страница 1: ...Radio Access Network MT3204 Series Installation Manual Describes product installation and requirement procedure Document Version 1 0 December 2018 Document Number 2600 00NFJUGAA ...

Страница 2: ...ity including liability to any person by reason of negligence will be accepted by SAMSUNG Electronics Co Ltd its subsidiaries or employees for any direct or indirect loss or damage caused by omissions from or inaccuracies in this document SAMSUNG Electronics Co Ltd reserves the right to change details in this publication without notice SNMTC v3 0312 This manual should be read and used as a guideli...

Страница 3: ...MT3204 Series Installation Manual v1 0 iii Copyright 2018 All Rights Reserved Samsung Networks documentation is available at http www samsungdocs com ...

Страница 4: ...6 Installation Tools 7 Chapter 2 Installing System 10 Installation Procedure 10 System Arrangement 11 Transporting and Unpacking 14 Bringing in Items 14 Unpacking 14 MMU Handling 15 Fixing MMU 16 Fixing Unit Bracket 16 Fixing Pole Type 17 Fixing Wall Type 31 MMU Tilting Swivelling 40 Chapter 3 Connecting Cables 73 Cabling Procedure 73 Guidelines for Cable Connections 74 Cable Path Inspection 74 Ca...

Страница 5: ...ights Reserved Connecting CPRI Cable 90 Connecting UDA Cable 94 Chapter 4 Inspect the Installation 99 Appendix A Acronyms 103 Appendix B Clean the Optical Connectors 104 Introduction 104 Measure the Optical Output and Connecting the Optical Connector 104 Appendix C Standard Torque 106 ...

Страница 6: ...racket Assembly Top 2 25 Figure 21 Fixing Pole Mount Bracket Assembly Top 3 26 Figure 22 Fixing Pole Mount Bracket Assembly Top 4 26 Figure 23 Fixing Pole Mount Bracket Assembly Top 5 27 Figure 24 Fixing Pole Mount Bracket Assembly Top 6 27 Figure 25 Fixing MMU on the Pole 1 29 Figure 26 Fixing MMU on the Pole 2 30 Figure 27 Fixing MMU on the Pole 3 31 Figure 28 MMU Marking Dimensions 33 Figure 29...

Страница 7: ...p Tilting 3 66 Figure 63 MMU Up Tilting 4 67 Figure 64 MMU Up Tilting 5 67 Figure 65 MMU Up Tilting 6 68 Figure 66 MMU Swiveling Adjustment 1 70 Figure 67 MMU Swiveling Adjustment 2 71 Figure 68 MMU Swiveling Adjustment 3 72 Figure 69 Procedure to Connect System Cable 73 Figure 70 Cable Connection Procedure 74 Figure 71 Cable Diagram 78 Figure 72 Connecting Ground Cable 1 80 Figure 73 Connecting G...

Страница 8: ...Bottom 37 Table 12 Parts and Tools for Fixing MMU 38 Table 13 MMU Down Tilting Adjustment Tools 40 Table 14 Parts and Tools for MMU Up Tilting 46 Table 15 Parts and Tools for Fixing Pole Mount Bracket Assembly Top Up Tilting 55 Table 16 Parts and Tools for Fixing MMU on the Pole 59 Table 17 MMU Up Tilting Adjustment Tools 62 Table 18 Tools for Swiveling MMU 69 Table 19 Recommended Minimum Allowed ...

Страница 9: ...ollow to avoid personal injury or fatality Provides antistatic precautions that you should observe Menu Commands menu command This indicates that you must select a command on a menu where menu is the name of the menu and command is the name of the command on that menu File Names and Paths These are indicated by a bold typeface For example Copy filename ext into the home folder1 folder2 bin folder ...

Страница 10: ...ter describes the procedures to install the MMU Chapter 3 Connecting Cables This chapter describes the procedures to connect the cables to the installed MMU Chapter 4 Inspect the Installation This chapter describes the procedures of inspecting installation status after the MMU installation and cabling is completed Appendix A Acronyms This appendix describes the acronyms used in this manual Appendi...

Страница 11: ...der EN 60825 1 During installation operation and maintenance never look into the end of an optical fiber directly or by reflection either with the naked eye or through an optical instrument Do not operate equipment with exposed fiber connectors cover these with fiber cables or blanking caps Do not remove equipment covers during operation unless requested to do so in the documentation Carry out nor...

Страница 12: ...lage can cause severe damage Cooling The product cools down by its own set of cooling fans housed in a fan module Each fan module detects a fan that is not operating normally LEDs on the front panel of the fan tray provide an alarm indication in the event of fan failure In the event of fan failure take urgent remedial action to restore full cooling capacity Take appropriate measures to ensure that...

Страница 13: ...y produce hazardous conditions on the network When the power supply is obtained by a rectifier safety isolation transformer the supply must meet the requirements of EN 60950 providing double reinforced insulation between hazardous voltages and SELV TNV circuits Any battery must be separated from hazardous voltages by reinforced insulation Indirect Connection Before indirectly connecting any equipm...

Страница 14: ... replacement please contact your service provider Do not attempt to remove the battery or dispose it in a fire Do not disassemble crush or puncture the battery End of life recycling materials information is available from Samsung California USA Only This Perchlorate warning applies only to primary CR Manganese Dioxide Lithium coin cells in the product sold or distributed ONLY in California USA Per...

Страница 15: ...with other commercial wastes for disposal Correct disposal of batteries in this product Applicable in countries with separate collection systems The marking on the battery manual or packaging indicates that the battery in this product should not be disposed of with other household waste Where marked the chemical symbols Hg Cd or Pb indicate that the battery contains mercury cadmium or lead above t...

Страница 16: ... Before Installation This chapter introduces the MMU system and describes the items that you should know before installation MMU View and External Interface This section provides the physical structure of the MMU and its interfaces MMU View The figure below depicts the physical structure of the MMU ...

Страница 17: ...l Rights Reserved Figure 1 MMU View MMU External Interface The figure below depicts the external interface structure of the MMU Bottom View Front View 5 27 134 Right View Left View Rear View Top View 9 0 230 40 3 1023 15 6 396 5 4 5 115 4 5 115 24 7 626 5 Unit in mm Center Line for the Antenna Element ...

Страница 18: ...nfidential Chapter 1 Before Installation MT3204 Series Installation Manual v1 0 3 Copyright 2018 All Rights Reserved Figure 2 MMU External Interface DC_PWR L0 Ground Terminal MMU Bottom View L1 L2 L3 UDA ...

Страница 19: ... 48 V DC 38 to 57 V DC Power Consumption 428 W 100 Load U D 2 7 Dimension W D H 9 0 in 230 mm 5 3 in 134 mm 40 3 in 1023 mm Weight 53 57 lb 24 3 kg with port guard Operating Temperature 40 to 50 C without Solar load Operating Humidity 5 to 100 RH condensing not to exceed 30 g m3 absolute humidity Cooling Method Natural convection cooling Function Split LTE DL Option 7 2a UL Option 8 Spectrum Analy...

Страница 20: ...f the power supply is off when installing the system Installing the system with power on may cause system damage or fatal human injury when connecting or disconnecting cables Ensure that workers wear protection gloves and goggles to prevent injury from debris while drilling holes in a wall or ceiling Do not wear accessories such as watches and rings to prevent electrical shock Cover unused ports w...

Страница 21: ...romagnetic field After Installing After installation remove any debris produced during the work and clean up the installation site In the system the laser beam light runs through the optical cable The workers must handle the optical cables with care as the laser beam can seriously damage the eyes Ensure that the workers do not damage installed cables while cleaning the system While cleaning the po...

Страница 22: ...astening M6 SEMS 4 Torque Wrench Apply a torque range 10 to 50 lbf in Tightening M6 hexagonal bolt Apply a torque range 100 to 400 lbf in Tightening M10 M12 hexagonal bolt 5 Torque Wrench Spanner Head Apply hexagonal bolt head 10 mm for 10 to 50 lbf in Tightening M6 hexagonal bolt Apply hexagonal bolt head 17 mm for 100 to 400 lbf in Tightening M10 hexagonal nut Apply hexagonal bolt head 19 mm for...

Страница 23: ...Vacuum Cleaner Normal Removing dust during the drilling work 16 Cable Cutter 0 2 1 3 in 6 32 mm Cutting cable 17 Crimping Tool 14 AWG 4 AWG 1 5 to 16 mm2 Crimping pressure terminal 18 Cable Stripper Apply cable thickness 1 5 to 6 2 in 4 to 16 mm Removing cable sheath 19 Nipper Basic Tool Cutting cable 20 Flush cutter Basic Tool For cutting cable tie 21 Industrial Scissor Basic Tool Cutting 22 Knif...

Страница 24: ...ecking MMU Tilting 26 Fiber Optical Test Set Wave length 1270 nm 1310 nm 1550 nm single mode 850 nm 1310 nm multi mode Checking optical level 27 Antenna Alignment Tool Checking azimuth and tilting The required installation tools may vary depending on the site conditions In addition to the basic tools protractor ladder safety equipment and cleaning tools must also be arranged considering the site c...

Страница 25: ...the procedures for transporting unpacking and installing the MMU Installation Procedure The figure below depicts the overall procedures for installing the MMU Figure 3 Procedure to Install the MMU Foundation Work Unpacking and Transporting Fixing System Unpacking Items Bringing in Items Fixing Unit Bracket Fixing Mounting Bracket Fixing MMU ...

Страница 26: ... of the front of the MMU change according to the tilt angle and the maximum dimensions are described in the figure below MMU Arrangement_ Down Tilting 15 When fixing a mounting bracket the length of stud bolts are 8 7 in 220 mm for the pole diameter 50 100 A Unit in mm Down Tilting 15o Tilting 0o Top View 20 1 510 Top View 28 3 720 31 800 12 300 Front View 12 300 16 400 31 800 31 800 Example Pole ...

Страница 27: ...t_Wall Type Installation The dimensions of the front of the MMU change according to the tilt angle and the maximum dimensions are described in the figure below MMU Arrangement_ Down Tilting 15 Unit in mm Down Tilting 15o Tilting 0o Front View Top View 16 400 12 300 18 6 476 W 230 H 1023 Top View 26 8 686 Wall Wall 31 800 12 300 31 800 31 800 ...

Страница 28: ... Figure 6 MMU Arrangement_Swivelling The dimensions of the front of the MMU change according to the tilt angle and the maximum dimensions are described in the figure below MMU Arrangement_ Left Right Swivelling 30 Unit in mm Left Swivelling 30o Right Swivelling 30o Top View 18 8 479 Top View 17 6 448 17 6 448 18 8 479 ...

Страница 29: ...must be carried by people ensure there are enough people to carry the system The system must not be shocked physically The system should be protected from dust moisture and static electricity Unpacking To unpack the items ensure the following The items must be packed until they reach the installation place The items are classified in accordance with each job specification and stored at a place tha...

Страница 30: ...ndling When moving the MMU or its packaging box use the handles located on both sides of the MMU or its packaging box Lifting Hazard Single person lift could cause injury Get help when moving or lifting Figure 7 Transporting the MMU MMU Handle MMU Rear Transporting the Packaging Box Transporting the MMU Packaging Box Handle ...

Страница 31: ...ing the unit bracket make sure that you have the items mentioned in the table below Table 2 Parts and Tools for Fixing Unit Bracket on MMU Category Description Parts Unit Bracket 2 EA Fasteners M6 L20 hexagonal bolt Washer assembly 8 EA Recommended Torque Value M6 Hex Bolt 43 lbf in Working Tools Torque Wrench 10 to 50 lbf in Torque Wrench Spanner Head apply hexagonal head 10 mm Spanner apply hexa...

Страница 32: ...ld be oriented toward the top of the MMU 2 Fix the unit bracket using fasteners Figure 9 Fixing Unit Bracket 2 Fixing Pole Type This section describes the procedures for fixing the system on the pole Assembling Pole Mount Bracket Bottom To assemble the pole mount bracket bottom for do the following Hook Hook MMU top side 1 2 M6 Hex Bolt Washer Assembly ...

Страница 33: ...ts Mounting Bracket Bottom Assembly 1 EA Rear Bracket 1 EA Fasteners M10 L220 Stud Bolt Assembly 2 EA M10 Flange Nut M10 Hexagon Nut 2 EA 2 EA Recommended Torque Value M10 Nut 217 lbf in Working Tools Torque Wrench 100 to 400 lbf in Torque Wrench Spanner head apply hexagonal head 17 mm Spanner 17 mm 1 Pass the stud bolt assembly through the pole mount bracket holes Figure 10 Fixing Pole Mount Brac...

Страница 34: ...e Mount Bracket Bottom 2 When assembling the front bracket and rear 2hole bracket make sure the up mark is facing upward 3 Slide the latch of the unit bracket until the lock of the pole mount bracket assembly is engaged Rear 2Hole Bracket M10 Stud Bolt Assembly M10 Flange Nut M10 Hex Nut 1 2 3 Front Bracket A B Rear 2Hole Bracket A B A B ...

Страница 35: ... to the next step Assembling Pole Mount Bracket Top To assemble the pole mount bracket top for do the following Prerequisites Before proceeding with assembling the pole mount bracket top make sure that you have the items mentioned in the table below Table 4 Parts and Tools for Fixing Pole Mount Bracket Top Category Description Parts Mounting Bracket Top Assembly 1 EA Rear Bracket 1 EA Fasteners M1...

Страница 36: ...king Tools Torque Wrench 100 to 400 lbf in Torque Wrench Spanner head apply hexagonal head 17 mm Spanner 17 mm 1 Pass the stud bolt assembly through the pole mount bracket holes Figure 13 Fixing Pole Mount Bracket Top 1 2 Insert the rear 4 hole bracket into the stud bolt M10 Stud Bolt Assembly Pole Mount Bracket 1 2 3 4 M10 Stud Bolt Assembly ...

Страница 37: ...x the fasteners temporarily Figure 15 Fixing Pole Mount Bracket Top 3 When assembling the front bracket and rear 4hole bracket make sure the up mark is facing upward Rear 4Hole Bracket Pole Mount Bracket Assembly Top Stud Bolt Assembly 1 2 Pole Mount Bracket Assembly Top M10 Flange Nut Stud Bolt Assembly M10 Hex Nut 1 2 Rear 4Hole Bracket Front Bracket A B A B A B ...

Страница 38: ...bly Top To lift the MMU do the following 1 Tie the rope in two carrying points of MMU Figure 16 Lifting MMU Pole Mount Bracket Assembly Top 1 Figure 17 Lifting MMU Pole Mount Bracket Assembly Top 2 Pole Mount Bracket Assembly Top Rope Carrying Point_1 Carrying Point_1 Carrying Point_1 Rope Rope MMU Carrying Point_1 Rope Carrying Point_1 Carrying Point_1 ...

Страница 39: ... the Pole To fix the pole mount bracket assembly top on the pole do the following Prerequisites Before proceeding with fixing the pole mount bracket assembly top on the pole make sure that you have the items mentioned in the table below Table 5 Parts and Tools for Fixing Pole Mount Bracket Assembly Top Category Description Parts Pole Mount Bracket Assembly Top 1 EA Recommended Torque Value M10 Nut...

Страница 40: ...ole Figure 19 Fixing Pole Mount Bracket Assembly Top 1 2 Place the rear 4 hole bracket horizontally in the fixed position Figure 20 Fixing Pole Mount Bracket Assembly Top 2 3 Insert the three loosened stud bolt assemblies into the fixing hole of the rear 4 hole bracket 1 2 Pole Pole Mount Bracket Assembly Top Pole mount Bracket Assembly Top Pole Rear 4Hole Bracket 1 2 ...

Страница 41: ...stud bolt assembly Figure 22 Fixing Pole Mount Bracket Assembly Top 4 The length of the stud bolts through the rear brackets must be the same 5 Turn it to the left of the plate fixed to the top and bottom of the back of the rear 4hole bracket by rotating them counterclockwise and re fix the plate Pole mount Bracket Assembly Top M10 Stud Bolt Assembly Rear 4Hole Bracket 1 2 Pole mount Bracket Assem...

Страница 42: ...d adjust the level Figure 24 Fixing Pole Mount Bracket Assembly Top 6 When fixing the pole mount bracket assembly top on a pole be sure to check the level of bracket After finishing the installation you can adjust the level minutely When occurring poor levelling adjust the position of fasteners used to fix the pole Rear 4Hole Bracket M4 Plate Fixing Screw Plate 1 2 3 M4 Plate Fixing Screw If it is...

Страница 43: ...Prerequisites Before proceeding with fixing the MMU on the pole make sure that you have the items mentioned in the table below Table 6 Parts and Tools for Fixing MMU on the Pole Category Description Recommended Torque Value M10 Nut 217 lbf in Working Tools Torque Wrench 100 to 400 lbf in Torque Wrench Spanner head apply hexagonal head 17 mm Spanner 17 mm 1 Hang the unit bracket hook of MMU on the ...

Страница 44: ... to the mount bracket assembly the hooks of the unit brackets must be completely inserted into the fixing grooves of the mount bracket assembly This ensures that the unit brackets stay intact during vibration or from external influences Pole Mount Bracket Assembly Top Pole Mount Bracket Assembly Bottom Unit Bracket Pole Mount Bracket Assembly Top Unit Bracket_Hook 1 2 3 2 1 ...

Страница 45: ...nto the rear 2 hole bracket fixing hole and then fix the flange and the hexagon nuts Figure 26 Fixing MMU on the Pole 2 The length of the stud bolts through the rear brackets must be the same 3 Turn it to the left of the plate fixed to the top and bottom of the back of the rear 2hole bracket by rotating them counterclockwise and re fix the plate Rear 2Hole Bracket Stud Bolt Assembly M10 Flange Nut...

Страница 46: ... and adjust when there is an issue For detailed instructions of how to use the RF alignment tool refer to the user manual per each manufacturer Fixing Wall Type This section describes the procedures for fixing the system on the wall Marking To marking do the following Prerequisites Before proceeding with the marking make sure that you have items mentioned in the following table M4 Plate Fixing Scr...

Страница 47: ...ferring to the System Leveling to check the positions are marked to be horizontal or vertical before drilling If the result shows they are not horizontal or vertical modify the marking positions When the position where the system will be placed is determined place the system on that position and then mark the positions where anchor bolts will be fixed This will reduce marking error range 1 Check t...

Страница 48: ...s 2 Place a marking paper on the fixing location and then check the level status using a level and adjust the level of marking paper 3 If the level status is normal mark the anchor bolt holes on a wall 27 7 705 Pole Mount Bracket Assembly Top Anchor Bolt Hole Pole Mount Bracket Assembly Bottom 9 1 250 Rear View Anchor Bolt Hole Unit in mm 40 3 1023 ...

Страница 49: ...ms mentioned in the following table Table 8 Parts and Tools for Drilling Anchoring Category Description Parts M12 Set Anchor Assembly 4 EA Working Tools Hammer Drill Concrete Drill Bit 0 7 in 17 mm Vacuum Cleaner Hammer Anchor Punch for M12 Set Anchor Table 9 Anchor Bolt Drill Bits and Hole Depth Category Anchor Bolt Drill Bits Hole Depth Wall Type M12 0 7 in 17 mm 2 2 in 55 mm 27 8 705 9 8 250 If...

Страница 50: ...perator may drill after drill template is removed or remove the drill template after drilling according to the installation site conditions 2 Fix set anchor to the drilled hole Figure 30 Drilling Anchor 1 3 Fix fasteners to anchor bolt temporarily O Remove the debris from the drilled hole Anchor Hole Cross Section 2 2 in 55 mm X 0 7 in 17 mm Vacuum Cleaner M12 Anchor Bolt Anchor Punch Hammer Ancho...

Страница 51: ...hat you have the items mentioned in the table below Table 10 Parts and Tools for Fixing Mount Bracket Top Assembly Category Description Parts Wall Mount Bracket Assembly Top Assembly Recommended Torque Value M12 hexagonal Nut 372 lbf in Working Tools Torque Wrench 100 to 400 lbf in Torque Wrench Spanner Head apply hexagonal head 19 mm Spanner 19 mm 1 Hang the mounting bracket top assembly fixing h...

Страница 52: ...tom To assemble the pole mount bracket bottom for do the following Prerequisites Before proceeding with assembling the pole mount bracket bottom make sure that you have the items mentioned in the table below Table 11 Parts and Tools for Assembling Wall Mount Bracket Bottom Category Description Parts Wall Mount Bracket Assembly Bottom 1 EA 1 Slide the latch of the unit bracket until the lock of the...

Страница 53: ... it is fully fixed before proceeding to the next step Fixing MMU on the Wall To fix the MMU on the wall do the following Prerequisites Before proceeding with fixing the MMU on the wall ensure that you have the items mentioned in the table below Table 12 Parts and Tools for Fixing MMU Category Description Recommended Torque Value M12 Hexagonal Nut 372 lbf in Working Tools Torque Wrench 100 to 400 l...

Страница 54: ... and fix the fastening material of the lower anchor bolt Figure 35 Fixing MMU 2 By using the RF alignment tool check the tilt and the azimuth and adjust when there is an issue For detailed instructions of how to use the RF alignment tool refer to the user MMU Wall Mount Bracket Assembly Top Wall Mount Bracket Assembly Bottom M12 Anchor Bolt Wall Wall Unit Bracket_Hook Pole Mount Bracket Assembly T...

Страница 55: ...erequisites Before proceeding with adjusting the MMU down tilting make sure that you have the items mentioned in the table below Table 13 MMU Down Tilting Adjustment Tools Category Description Recommended Torque Value M10 Hexagon Nut 217 lbf in Working Tools Torque Wrench 100 to 400 lbf in Torque Wrench Spanner head apply hexagonal head 17 mm Spanner 17 mm The MMU tilt angle can be adjusted down f...

Страница 56: ...018 All Rights Reserved 1 Rotate counterclockwise the fasteners on the mount bracket assembly bottom at the once or twice to loosen them MMU Right Pole Mount Bracket Assembly Top Angle Plate Angle Plate Configuration Example of Using Angle Plate MMU Right Tilt 0 Tilt 15 MMU Right 0 Hole 15 Hole ...

Страница 57: ... Figure 36 MMU Down Tilting 1 2 Rotate counterclockwise the fasteners number 2 3 5 on the mount bracket top assembly at the once or twice to loosen them 3 Do not detach the fasteners completely and loosen the 20 mm of the fasteners number 4 of the angle plate M10 Hex Nut 1 Right View Pole Mount Bracket Assembly Bottom ...

Страница 58: ...Manual v1 0 43 Copyright 2018 All Rights Reserved Figure 37 MMU Down Tilting 2 4 Remove the angle plate fixing bolt by pushing the angle plate outward Right View M12 Hex Nut 4 Angle Plate Angle Plate Fixing Bolt 20 mm Pole Mount Bracket Assembly Top 5 M10 Hex Nut 2 3 4 ...

Страница 59: ... 2 Installing System MT3204 Series Installation Manual v1 0 44 Copyright 2018 All Rights Reserved Figure 38 MMU Down Tilting 3 5 Adjust the tilt by pulling the MMU forward Right View Angle Plate 1 2 Angle Plate Fixing Bolt ...

Страница 60: ...st the down tilt of the MMU with the down tilting holes on the angle plate and place the angle plate on the angle plate fixing bolt Figure 40 MMU Down Tilting 5 7 Re tighten the loosened fasteners Right View Right View 1 2 Right View Operator A M10 Hex Nut Example of 15 Tilting 1 2 Operator B 3 Angle Plate Fixing Bolt Angle Plate Fixing Bolt Angle Plate ...

Страница 61: ...t To adjust the MMU up tilting do the following Prerequisites Before proceeding with adjusting the MMU up tilting make sure that you have the items mentioned in the table below Table 14 Parts and Tools for MMU Up Tilting Category Description Parts Pole Mount Bracket Assembly Top 1 EA Pole Mount Bracket Assembly Bottom 1 EA Recommended Torque Value M10 Nut 217 lbf in Working Tools Torque Wrench 100...

Страница 62: ...top bottom and reassemble 1 Loosen the fasteners M10 hex nut 2 EA of the pole mount bracket on the mount bracket assembly top and remove the stud bolt and sleeve 2 Remove the front bracket top from the pole mount bracket top Pole Mount Bracket Assembly Top for Down Tilting Pole Mount Bracket Assembly Bottom for Down Tilting Pole Mount Bracket Assembly Top for Up Tilting Pole Mount Bracket Assembly...

Страница 63: ...MMU Up Tilting 1 3 Loosen the mounting bracket M10 hex nut 2 EA of the pole mount bracket on the mount bracket assembly bottom and remove the stud bolt and sleeve 4 Remove the front bracket bottom from the pole mount bracket bottom Pole mount Bracket Assembly Top M10 Hex Nut 1 2 M10 Stud Bolt 3 4 Sleeve Pole Mount Bracket Top Front Bracket Top 5 6 ...

Страница 64: ...ure 43 Bracket Change for MMU Up Tilting 2 5 Position the front bracket bottom in line with the fixing hole of the pole mount bracket top and fix the sleeve and stud bolt with the M10 hex nut 2 EA 1 2 3 4 6 Pole Mount Bracket Assembly Bottom M10 Hex Nut Sleeve Pole Mount Bracket Bottom Front Bracket Bottom M10 Stud Bolt 5 ...

Страница 65: ...ge for MMU Up Tilting 3 The square nut that is fastened to the stud bolt should be positioned so that it is fully inserted into the square hole of the pole mount bracket Pole Mount Bracket Assembly Top for Up Tilting 5 6 3 4 M10 Stud Bolt Pole Mount Bracket Top Sleeve Right View Front Bracket Bottom 1 2 Front Bracket Top M10 Hex Nut Sleeve ...

Страница 66: ...stem MT3204 Series Installation Manual v1 0 51 Copyright 2018 All Rights Reserved 6 Position the front bracket bottom in line with the fixing hole of the pole mount bracket bottom and fix the sleeve and stud bolt with the M10 hex nut 2 EA ...

Страница 67: ... for MMU Up Tilting 4 The square nut that is fastened to the stud bolt should be positioned so that it is fully inserted into the square hole of the pole mount bracket 5 6 3 4 1 2 Pole Mount Bracket Bottom Front Bracket Top M10 Stud Bolt Pole Mount Bracket Bottom Sleeve Pole mount Bracket Assembly Bottom for Up Tilting Right View M10 Hex Nut ...

Страница 68: ...e pole mount bracket assembly bottom is engaged Figure 46 Bracket Change for MMU Up Tilting 5 If the latch of the unit bracket is not fully inserted and fixed the pole mount bracket assembly may detach and fall which can damage the equipment Ensure that it is fully fixed before proceeding to the next step Pole Mount Bracket Assembly Bottom for Up Tilting Unit Bracket 1 2 ...

Страница 69: ...lting To lift the MMU do the following 1 Tie the rope in two carrying points of MMU Figure 47 Lifting MMU Pole Mount Bracket Assembly Top 1 Figure 48 Lifting MMU Pole Mount Bracket Assembly Top 2 Rope Pole Mount Bracket Assembly Top for Up Tilting Rope Carrying Point_1 Carrying Point_2 Carrying Point_1 MMU Rope Carrying Point_1 Carrying Point_2 Carrying Point_1 Rope ...

Страница 70: ...op up tilting on the pole do the following Prerequisites Before proceeding with fixing the pole mount bracket assembly top up tilting on the pole make sure that you have the items mentioned in the table below Table 15 Parts and Tools for Fixing Pole Mount Bracket Assembly Top Up Tilting Category Description Parts Pole Mount Bracket Assembly Top Up Tilting 1 EA Recommended Torque Value M10 Nut 217 ...

Страница 71: ... alignment tool to determine the azimuth of the MMU to be installed on the pole Figure 50 Fixing Pole Mount Bracket Assembly Top Up Tilting 1 For detailed instructions of how to use the RF alignment tool refer to the user manual per each manufacturer 2 Place a pole mount bracket assembly top up tilting to the pole Figure 51 Fixing Pole Mount Bracket Assembly Top Up Tilting 2 Antenna Alignment Tool...

Страница 72: ...ly Top Up Tilting 3 4 Insert the three loosened stud bolt assemblies into the fixing hole of the rear 4 hole bracket Figure 53 Fixing Pole Mount Bracket Assembly Top Up Tilting 4 5 Tighten the flange and the hexagon nuts that are fastened to the stud bolt assembly Pole Mount Bracket Assembly Top Up Tilting Pole Rear 4Hole Bracket 1 2 Pole Mount Bracket Assembly Top Up Tilting Pole M10 Stud Bolt As...

Страница 73: ... rear brackets must be the same 6 Turn it to the left of the plate fixed to the top and bottom of the back of the rear 4hole bracket by rotating them counterclockwise and re fix the plate Figure 55 Fixing Pole Mount Bracket Assembly Top Up Tilting 6 Do not take the fasteners out completely Pole Mount Bracket Assembly Top Up Tilting Pole M10 Flange Nut M10 Hex Nut 1 2 Rear 4Hole Bracket M4 Plate Fi...

Страница 74: ...g adjust the position of fasteners used to fix the pole mount bracket assembly top up tilting or its levelling status Fixing MMU Up Tilting Before proceeding with fixing the MMU on the pole make sure that you have the items mentioned in the table below Table 16 Parts and Tools for Fixing MMU on the Pole Category Description Recommended Torque Value M10 Nut 217 lbf in M4 Screw 13 lbf in Working Too...

Страница 75: ...p Tilting on the Pole 1 When the MMU is fixed to the mount bracket assembly the hooks of the unit brackets must be completely inserted into the fixing grooves of the mount bracket assembly This ensures that the unit brackets stay intact during vibration or from Pole Mount Bracket Assembly Top Up Tilting Pole Mount Bracket Assembly Bottom Up Tilting Unit Bracket 1 2 3 Pole Mount Bracket Assembly To...

Страница 76: ...ly into the rear 2 hole bracket fixing hole and then fix the flange and the hexagon nuts Figure 58 Fixing MMU Up Tilting on the Pole 2 The length of the stud bolts through the rear brackets must be the same 3 Turn it to the left of the plate fixed to the top and bottom of the back of the rear 4hole bracket by rotating them counterclockwise and re fix the plate 1 2 3 Rear 2Hole Bracket Stud Bolt As...

Страница 77: ...sue For detailed instructions of how to use the RF alignment tool refer to the user manual per each manufacturer MMU Up Tilting Adjustment To adjust the MMU up tilting do the following Table 17 MMU Up Tilting Adjustment Tools Category Description Recommended Torque Value M10 Hexagon Nut 217 lbf in Working Tools Torque Wrench 100 to 400 lbf in Torque Wrench Spanner head apply hexagonal head 17 mm S...

Страница 78: ...ed down from 0 to 15 by 1 and the angle plate is used when tilting 1 Rotate counterclockwise the fasteners on the pole mount bracket assembly top up tilting at the once or twice to loosen them Angle Plate Pole Mount Bracket Assembly Top Up Tilting Angle Plate Configuration Example of Using Angle Plate MMU Right MMU Right 0 Hole 15 Hole Tilt 0 Tilt 15 ...

Страница 79: ... MMU Up Tilting 1 2 Rotate counterclockwise the fasteners number 2 3 5 on the mount bracket assembly bottom up tilting at the once or twice to loosen them 3 Do not detach the fasteners completely and loosen the 20 mm of the fasteners number 4 of the angle plate Right View Pole Mount Bracket Assembly Top Up Tilting M10 Hex Nut 1 ...

Страница 80: ...v1 0 65 Copyright 2018 All Rights Reserved Figure 61 MMU Up Tilting 2 4 Remove the angle plate fixing bolt by pushing the angle plate outward Right View M12 Hex Nut 4 Angle Plate Angle Plate Fixing Bolt 20 mm Pole Mount Bracket Assembly Bottom Up Tilting 2 3 4 5 M10 Hex Nut 1 ...

Страница 81: ... Installing System MT3204 Series Installation Manual v1 0 66 Copyright 2018 All Rights Reserved Figure 62 MMU Up Tilting 3 5 Pull the MMU forward to adjust the tilting angle Right View Angle Plate Angle Plate Fixing Bolt 1 2 ...

Страница 82: ...lt into the designated hole of the angle plate depending on the required angle and fix the fastening material Figure 64 MMU Up Tilting 5 7 Tighten the loosened fastening material of the mounting bracket assembly top bottom for tilting up follow the order 1 to 3 indicated in the figure above and then fix them Right View Right View 1 2 Right View Operator A Example of 15 Tilting Operator B 1 2 3 Ang...

Страница 83: ...l check the tilt and the azimuth and adjust when there is an issue For detailed instructions of how to use the RF alignment tool refer to the user manual per each manufacturer Swiveling The MMU swivel angle can be adjusted left right from 0 to 30 Right View Pole Mount Bracket Assembly Top Up Tilting 4 M10 Hex Nut M10 Hex Nut 2 1 3 Pole Mount Bracket Assembly Bottom Up Tilting ...

Страница 84: ...tems mentioned in the table below Table 18 Tools for Swiveling MMU Category Description Recommended Torque Value M10 Hexagon Nut 217 lbf in Working Tools Torque Wrench 100 to 400 lbf in Torque Wrench Spanner head apply hexagonal head 17 mm Spanner 17 mm 1 Loosen the MMU by turning M10 hexagon nut of mounting bracket two or three times counterclockwise Do not separate it completely Example of Left ...

Страница 85: ... Installation Manual v1 0 70 Copyright 2018 All Rights Reserved Figure 66 MMU Swiveling Adjustment 1 2 Pull the MMU left right to adjust the swiveling angle Wall Mount Bracket Assembly Top M10 Hex Nut Wall Mount Bracket Assembly Bottom M10 Hex Nut 1 2 3 4 ...

Страница 86: ...2 Installing System MT3204 Series Installation Manual v1 0 71 Copyright 2018 All Rights Reserved Figure 67 MMU Swiveling Adjustment 2 3 Fix the M10 hex nut of mount bracket top bottom assembly 1 2 Left Swiveling 30 Example ...

Страница 87: ...MU Swiveling Adjustment 3 4 By using the RF alignment tool check the tilt and the azimuth and adjust when there is an issue For detailed instructions of how to use the RF alignment tool refer to the user manual per each manufacturer Wall Mount Bracket Assembly Top M10 Hex Nut Wall Mount Bracket Assembly Bottom M10 Hex Nut 3 4 1 2 ...

Страница 88: ...the procedures to connect cables to the MMU system and to label the cables Cabling Procedure The figure below depicts the procedure to connect system cables Figure 69 Procedure to Connect System Cable Grounding Power Cabling Connecting Ground Cable Interface Cable Connection Connecting CRPI Cable Connecting UDA Cable Connecting Power Cable e ...

Страница 89: ... mistakes The sequence of cable cutting and installation of the cable workflow can be changed depending on the field situation such as cutting after installing or installing after cutting Cable Path Inspection When installing the cable that interconnects rectifier Main Ground Bar MGB backhaul device and so on within the system the cable path length and cable installation method must be inspected T...

Страница 90: ... and a brush Cable Installation This process involves running the cable along the cabling path to the target connector of the system or an auxiliary device This is done after cable path inspection and cable cutting are completed To install the cable follow these guidelines Be careful not to damage the cable If the cable is damaged cut out the damaged section before installing or replace the cable ...

Страница 91: ...mage to the cables or personal injury Cut off the remainder of the cable thread by leaving about 50 mm of extra length to prevent the knot from easily getting untied If there is a chance of contact failure to occur in the connector connection due to tension bind the cable at the closest location to the connector Connector Attachment This process involves assembling a connector to an installed cabl...

Страница 92: ...efore attaching the tags When connecting the cables always connect the ground cable first If a worker contacts the equipment connects a cable or performs maintenance without connecting the ground cable the system can be damaged or the worker may be injured due to static electricity and short circuit When performing cable work for the system proceed with the ground work before any other work to pre...

Страница 93: ... 6 AWG 1C MMU Rectifier 2 Power Cable 10 AWG 2C 8 AWG 2C CDU 3 CPRI Cable Single Mode Outdoor Type External Alarm Device 4 UDA Cable Assembly The inlet hole finishing method of external equipment must be done after consultation with operation company if the cable is connected to external equipment such as optical distribution box Cables Power cable CPRI cables and UDA cable MGB 4 UDA Cable Externa...

Страница 94: ...over voltage and lightning To provide a discharge path for surge voltage generated by lightning and power switch To protect the system from static electricity To eliminate or minimize the high frequency potential in the system housing To provide a conductor for the balance and stability of high frequency current To stabilize the potential of the circuit against the ground Connecting Ground Cable T...

Страница 95: ...be used For example Manufacturer Panduit MMU 6 AWG Pressure Terminal LCD6 14A L It is recommended to apply antioxidant ex grease to prevent oxidation before connecting the pressure terminal 1 Install the ground cable from the MGB to the MMU ground terminal as shown in figure below Figure 72 Connecting Ground Cable 1 2 Remove the fastener M6 SEMS from the MMU ground terminal 3 Assemble a pressure t...

Страница 96: ...Cables MT3204 Series Installation Manual v1 0 81 Copyright 2018 All Rights Reserved fasteners Figure 73 Connecting Ground Cable 2 MMU 3 4 2 M6 SEMS Hex Ground Cable M6 SEMS Hex MMU Ground Terminal Heat Shrink Tube 1 2 Pressure Terminal ...

Страница 97: ...resistant temperature of the power cable should be 90 C or more Install the power cable to the power port of the system by considering the radius of curvature of its cable specification and then cut the cable If the operator installs the cable after cutting there may be length difference among the core wires at the end of the cable because of cable curvature This may result in poor contact after t...

Страница 98: ...ols for Connecting Power Cable Category Description Installation Section DC Distributor MMU power input port Cable 10 AWG 2C 8 AWG 2C Minimum Cable bend Radius Dynamic bend radius 8 OD Static bend radius 12 OD Connector Distributor Check specifications of DC distributor output terminal per site and prepare fasteners MMU DC JONHON Push Pull Type CT48J 1502TSCBM 07 to OPEN Working Tools Cable Cutter...

Страница 99: ...nnector Pin Number Description Color 1 Install the power cable from the distributor to the MMU Figure 75 Connecting Power Cable 1 2 Separate the cap from the MMU side and cable side connector Cable Side Connector MMU Side DC_PWR Port Bump Groove Bump Groove Pin 1 Pin 2 Pin 1 Pin 2 MMU Bottom View DC Distributor DC Power Cable ...

Страница 100: ...8 All Rights Reserved Figure 76 Connecting Power Cable 2 3 Insert the connector aligning white dot of the cable side connector and white dot of the system side connector 4 When inserting the connector push the shell to upper side MMU Power Cable MMU Rear Cap DC_PWR Port Cap Power Connector 2 1 1 2 ...

Страница 101: ...on the system side connector becomes invisible The method for connecting or disconnecting the power connector is as follows For connecting the connector push the shell to upper side For disconnecting the connector pull the coupling nut to lower side MMU Rear System side connector s white dot Push Shell Cable side connector s white dot Power Cable Assembly 1 2 White Line is invisible White Line is ...

Страница 102: ...Confidential Chapter 3 Connecting Cables MT3204 Series Installation Manual v1 0 87 Copyright 2018 All Rights Reserved Connector 연결 Connector 분리 Push Shell Pull Coupling Nut ...

Страница 103: ... module from the optical module cage by pulling the optical module removal Tool Figure 79 Optical Module Removal 2 When desorbing an optical module use a dedicated tool optical module desorption tool to remove the handle by opening it for about 90º When the optical module is detached without using the dedicated tool the optical module may be jammed and the handle may be damaged due to a lack of op...

Страница 104: ...val 3 To inset optical module do the following Push the optical module into the optical module cage within the connector Figure 81 Optical Module Insert Inset the optical module s bail facing the front of the system to the port Do not inset when the optical module s bail is unlocked Handle 90º open Handle 45º open 1 2 System Inside Optical Module Cage Optical Module Optical Connector 1 2 System Re...

Страница 105: ...ng Tools Optical Connector Cleaner In the system the laser beam light runs through the optical cable The exposure of the laser beam on worker s eye may cause serious injury so that it should be handled with care Remove the cap of the optical connector before connecting Before connecting the optical cable check if the ferrule of the connector is soiled Be careful to keep the cutting section away fr...

Страница 106: ...ble side should be cleaned first by using the optical connector cleaner Appendix B for more information 1 Install the CPRI cable from the CDU to the MMU L0 port Figure 82 Connecting CPRI Cable 1 2 Separate the cap from the system side connector L0 port Figure 83 Connecting CPRI Cable 2 The method for connecting disconnecting the cap push pull type is as follows Ferrule Before Removing Cap After Re...

Страница 107: ...Separate the cap from the cable side connector Figure 84 Connecting CPRI Cable 3 4 The latch of cable side connector should be toward the rear side Before connecting the CPRI cable connector the Ferrule of the connecter of cable side should be cleaned first by using the optical connector cleaner Appendix B for more information Coupling Nut Cap 1 2 3 Cap Cap DLC Plug Cap Cap 1 2 3 4 ...

Страница 108: ...ecting CPRI Cable 4 5 Insert the DLC plug to the system side s optical module Figure 86 Connecting CPRI Cable 5 When the connector is fastened tight the white line on the system side connector should be invisible or hidden DLC Plug Latch Cable side connector s white dot Front Side Rear Side DLC Plug System side s optical module 1 2 ...

Страница 109: ...uisites Before proceeding with connecting the UDA cable make sure that you have the items mentioned in the table below Table 25 Parts and Tools for Connecting UDA Cable Category Description Installation Section MMU UDA Port to External alarm device Cable UDA Cable Assembly Cat 5e 24AWG 4P Minimum Cable bend Radius Operation 5 OD Installation 10 OD Connector External alarm device Check specificatio...

Страница 110: ... the UDA cable pin map Table 26 UDA Cable Pin Map Pin Color Function 1 White Blue UDA0 2 Blue UDA0_RTN 3 White Orange UDA1 6 Orange UDA1_RTN 4 White Green UDA2 5 Green UDA2_RTN 7 White Brown UDA3 8 Brown UDA3_RTN 1 Install the UDA cable from the external alarm device to the MMU Figure 87 Connecting UDA Cable 1 2 Separate the cap from the MMU side and cable side connector External Alarm Device UDA ...

Страница 111: ...right 2018 All Rights Reserved Figure 88 Connecting UDA Cable 2 3 The latch of cable side connector should be toward the front of the MMU Figure 89 Connecting UDA Cable 3 MMU MMU Front UDA Cable Cap UDA Port 1 2 Cap 1 2 RJ45 Plug Latch Cable side connector s white dot Front Side Rear Side ...

Страница 112: ...4 When the connector is fastened tight the white line on the system side connector becomes invisible The method for connecting or disconnecting the backhaul RJ45 connector is as follows For connecting the connector push the shell to upper side For disconnecting the connector pull the coupling nut to lower side RJ45 Plug System side UDA port 1 2 White Line White Line is invisible White Line is visi...

Страница 113: ...Confidential Chapter 3 Connecting Cables MT3204 Series Installation Manual v1 0 98 Copyright 2018 All Rights Reserved Shell Coupling Nut Push Pull ...

Страница 114: ...the installation status Figure 91 Installation Inspection Procedure Inspection Plan Create an inspection sheet per system and select an inspector to set an inspection schedule per site NO YES Sharing Inspection Results Taking Corrective Actions On site Inspection Inspection Checklist Inspection Checklist Corrective Actions Sharing the Results of Corrective Actions and Preparing Preventive Plan Ins...

Страница 115: ...haring the Results of Corrective Actions and Preparing Preventive Plan After the corrective actions are all completed the inspector must share the results with the installation operator and relevant departments The inspector must prepare a preventive plan to avoid the reoccurrence of the similar problems Construction Situation Checklist The table below outlines the checklist to inspect the install...

Страница 116: ...ent Checking tag installation method Power Installation status of power supply Power supply capacity Output voltage tester Installation of circuit breaker Checking circuit breaker capacity Cable specification Checking the specification Checking the limit distance Cabling Cable damage Proper installation route Compliance with the radius of curvature Cable binding status Binding status Binding inter...

Страница 117: ...on of a connector Fastening condition of a connector Checking compliance with fastening torque value Installation status of cable tag Position Marking content Checking tag installation method Checking tag installation method Others Reserved ports Checking port cap fastening status Cable inlet status Connection of equipment I O port Checking fastening status Conduit Cable Gland Cable tray and duct ...

Страница 118: ... Reserved Appendix A Acronyms AC Alternating Current CBRS Citizen Broadband Radio Service DC Direct Current DL Downlink MMU Massive MIMO Unit MGB Main Ground Bar RTN Return SELV Safe Extra Low Voltage SEMS pre asSEMbled washers and screws S FTP Screened Foiled Twisted Pair UL Uplink ...

Страница 119: ...leaner use the products shown in the example below or their equivalents Examples Manufacturer USCONEC http www usconec com IBCTM Brand Cleaner P N 9393 For LC LC and MU Connector Cleaning IBCTM Brand Cleaner P N 9392 For SC Connector Cleaning IBCTM Brand Cleaner P N 12910 For ODC Connector Cleaning Manufacturer The Fibers www thefibers com HuxCleaner 1 25 mm Type For LC and MU Connector Cleaning H...

Страница 120: ...ghts Reserved 2 If the optical output measurement result meets the reference value clean the connector again and connect it 3 If the measurement result does not meet the reference value discard the cable replace it with a new cable and then clean the new one and connect it to the system Optical Power meter LC PC Plug ...

Страница 121: ...4 1 5 13 15 M5 2 8 25 29 M6 4 9 43 50 M8 12 110 127 M10 25 217 250 M12 42 372 428 Table 29 Brass Bolts Torque Value Bolt Spec Torque Value N m Torque Value lbf in Torque Value kgf cm M6 2 9 26 30 M8 6 3 56 64 Table 30 Connector Connection Torque Value Connector Torque Value N m Torque Value lbf in Torque Value kgf cm SMA connector 0 59 5 2 6 TNC connector 0 88 7 8 9 N type connector 2 17 20 DIN ty...

Страница 122: ...MT3204 Series Installation Manual Document Version 1 0 2018 Samsung Electronics Co Ltd All rights reserved ...

Отзывы: