Confidential
Chapter 2
Installing System
MT3204 Series Installation Manual v1.0
38
Copyright © 2018, All Rights Reserved.
Figure 34.
Assembling Wall Mount Bracket-Bottom
If the latch of the unit bracket is not fully inserted and fixed, the wall mount
bracket assembly may detach and fall, which can damage the equipment. Ensure
that it is fully fixed before proceeding to the next step.
Fixing MMU on the Wall
To fix the MMU on the wall, do the following:
Prerequisites
Before proceeding with fixing the MMU on the wall, ensure that you have the
items mentioned in the table below:
Table 12.
Parts and Tools for Fixing MMU
Category
Description
Recommended Torque Value
M12 Hexagonal Nut
372 lbf
in
Working Tools
Torque Wrench (100 to 400 lbf
in)
Torque Wrench Spanner Head (apply hexagonal head: 19 mm)
Spanner (19 mm)
Wall Mount Bracket
Assembly-Bottom
Unit Bracket
1
2