Confidential
Chapter 3
Connecting Cables
MT3204 Series Installation Manual v1.0
90
Copyright © 2018, All Rights Reserved.
Connecting CPRI Cable
To connect a CPRI cable, do the following:
Prerequisites
Before proceeding with connecting the CPRI cable, make sure that you have the
items mentioned in the table below:
Table 24.
Parts and Tools for connecting CPRI Cable
Category
Description
Installation Section
CDU to MMU L0 Port
Cable
CPRI Cable (Optical, Single Mode, for Outdoor Type)
Bend Radius
10 × OD
Connector
MMU
JONHON, Push Pull Type, PDLC03T03 (DLC/UPC)
Working Tools
Optical Connector Cleaner
In the system, the laser beam light runs through the optical cable.
The exposure of the laser beam on worker’s eye may cause serious injury so that it
should be handled with care.
Remove the cap of the optical connector before connecting.
- Before connecting the optical cable, check if the ferrule of the connector is
soiled. Be careful to keep the cutting section away from dust or foreign material.
If the cable is soiled with foreign material, do not blow to remove them.
- Make sure to clean the connector in accordance with the cleaning directions in
Annex.
- Do not touch the ferrule at the end of optical cable because it is easy to be
damaged.
Optical Module Bail
[Raised: Lock]
[Lowered: Unlock]
System
Rear Side
System
Rear Side