iDCS 500
PROGRAMMING
TECHNICAL MANUAL
PART 2 NOVEMBER 2001
MMC: 204
COMMON BELL CONTROL
DESCRIPTION:
Determines whether the common bell relay contacts have an interrupted or
continuous closure when activated. If interrupted is chosen, the relay follows an
internal C.O. ring pattern of one second closed followed by three seconds open. By
default, all common bell relay pairs are assigned as 380X.
PROGRAM KEYS
UP & DOWN
Used to scroll through options
KEYPAD
Used to enter selections
SOFT KEYS
Move cursor
SPK
Used to store data and advance to next MMC
ACTION DISPLAY
1. Press TRSF 204
Display shows current setting
[3801] COM/LD BELL
CONTINUOUS
2. Dial common bell number
OR
[3801] COM/LD BELL
CONTINUOUS
Press UP or DOWN key to make selection of
common bell numbers and press RIGHT soft
key to advance cursor
3. Dial 0 for continuous or 1 for interrupted
operation
[3802] COM/LD BELL
INTERRUPTED
OR
Use UP or DOWN to scroll through options
Press RIGHT soft key to return to step 2
4. Press TRSF to store and exit
OR
Press SPK to store and advance to next
MMC
DEFAULT DATA: CONTINUOUS
RELATED ITEMS:
HELP
Table of
Contents
HOME
PAGE
Содержание iDCS 500
Страница 3: ...iDCS 500 PROGRAMMING TECHNICAL MANUAL PART 1 NOVEMBER 2001 1 1 2 HELP Table of Contents HOME PAGE ...
Страница 487: ...COPY AS NEEDED 11 01 SHEET ______ OF ______ MMC 602 STATION GROUP NAME GROUP NAME HELP Table of Contents HOME PAGE ...
Страница 503: ...COPY AS NEEDED 11 01 SHEET ______ OF ______ MMC 706 SYSTEM SPEED DIAL BY NAME BIN NAME HELP Table of Contents HOME PAGE ...