iDCS 500
PROGRAMMING
TECHNICAL MANUAL
PART 2 APRIL 2002
MMC: 506
2. Dial tone number from above list (0–9, e.g., 9)
OR
TRSFER TONE
INTERRUPT TONE
Press UP or DOWN key to select tone, press
LEFT soft key and advance to step 3
3. Dial tone option 0 for CONTINUOUS or
1 for INTERRUPT
TRSFER TONE
INTERRUPT TONE
OR
Press UP or DOWN key to select tone
control and press RIGHT soft key to advance
to step 4
OR
Press LEFT soft key to return to step 2
4. Dial new value for interrupt times (must be
four digits)
TRSFER TONE:0100
9900 0100 9900
Press RIGHT soft key advances cursor
Press LEFT soft key retreats cursor
If valid entry, system returns to step 2
5. Press TRSF to store and exit
OR
Press SPK to store and advance to next MMC
DEFAULT DATA: SEE BELOW FOR CADENCES. BY DEFAULT DIAL TONE AND
MESSAGE WAIT TONE ARE CONTINUOUS.
TONE ON
OFF
ON
OFF
0 BUSY
TONE
500 500
500
500
1 CONFIRM/BARGE-IN
TONE
50 50 50 50
2 DIAL
TONE
1000 250
1000
250
3
DND/NO MORE TONE
250
250
250
250
4 ERROR
TONE
250 250
250
250
5 HOLD/CAMP-ON
TONE 500
3500
500
3500
6
MESSAGE WAIT TONE
1000
250
1000
250
7
RING BACK TONE
1000
3000
1000
3000
8 RING
TONE
1000
3000
1000
3000
9 TRANSFER
TONE
100 100
100
100
10
DID RINGBACK TONE
2000
4000
2000
4000
NOTE: All times are in milliseconds.
RELATED ITEMS: NONE
HELP
Table of
Contents
HOME
PAGE
Содержание iDCS 500
Страница 3: ...iDCS 500 PROGRAMMING TECHNICAL MANUAL PART 1 NOVEMBER 2001 1 1 2 HELP Table of Contents HOME PAGE ...
Страница 487: ...COPY AS NEEDED 11 01 SHEET ______ OF ______ MMC 602 STATION GROUP NAME GROUP NAME HELP Table of Contents HOME PAGE ...
Страница 503: ...COPY AS NEEDED 11 01 SHEET ______ OF ______ MMC 706 SYSTEM SPEED DIAL BY NAME BIN NAME HELP Table of Contents HOME PAGE ...