2. Safety
2.3.1
Basic Specifications
PV Generator Data (DC)
Max. input total power
6.6 kWp
Max. input power per string
3.3 kWp
Max. input voltage
550 V
Min. input voltage/Initial input voltage
125 V/150 V
MPPT voltage range
125 V~500 V
Max. input current per string
15 A
Number of independent MPP trackers
2
Battery Data (DC)
Battery nominal capacity/usable capacity
3.6 kWh/3.24kWh
DOD(Depth of Discharge)/Range
90% (5~95%)
Battery voltage range/nominal voltage
48.0 V~65.9 V/60 V
Battery Max. current
46.3 A
Battery DC/DC Converter Data
Rated Power
2.0 kW
Technology
Isolated
Grid Connection Data (AC)
Rated power
4.6 kW
Max. apparent AC power
5 kVA
Max. current
20 A
Max. allowed current for fuse protection
32 A
Nominal AC voltage/range
230 V/184 V~264 V
Rated power frequency
50 Hz
[Table 2-2: Basic Specifications]
2.3.2
Grounding the PV Inverter
The PV inverter complies with the local requirements for grounding the PV inverter.
Samsung SDI recommends connecting and grounding the PV inverter
’
s frame and other
electricity conducting surfaces in such a way that there is continuous conduction in order to
achieve maximum protection for systems and persons. And the PV inverter
’
s DC (+) pole
and DC (-) pole are not permitted to be grounded.
8
Australia (Eng.) 05/2015. Rev1.1
Содержание ELSR362-00004
Страница 13: ...2 Safety Figure 2 1 Connection Diagram Australia Eng 05 2015 Rev1 1 5 ...
Страница 27: ...4 Installation Figure 4 9 A fork lifter with height of 85 200mm Australia Eng 05 2015 Rev1 1 19 ...
Страница 30: ...5 Electrical Connections Figure 5 2 PV connections 22 Australia Eng 05 2015 Rev1 1 ...
Страница 49: ...5 Electrical Connections Figure 5 25 Side view after side cover assembly Australia Eng 05 2015 Rev1 1 41 ...
Страница 103: ...Australia Eng 05 2015 Rev1 1 ...