![Samson EB 31a-23 Скачать руководство пользователя страница 25](http://html1.mh-extra.com/html/samson/eb-31a-23/eb-31a-23_mounting-and-operating-instructions_4031618025.webp)
8-1
EB 31a-23_EN
Edition: November 2021
Speci
fi
cations subject to change
Malfunctions
8 Malfunctions
The work described in this section is only to be performed by fully trained and quali
fi
ed personnel.
8.1 Troubleshooting
Malfunction
Possible reasons
Recommended action
Uneven rotation
Inadequate supply
Check the supply system and make sure that the supply pressure is correct.
Missing lubricant
Disassemble the actuator, lubricate all the sliding parts and reassemble the ac-
tuator.
Worn components
Disassemble the actuator, inspect and replace the worn/damaged compo-
nents.
Control system
Make sure the control system components are correctly assembled. Check the
control system documentation and contact the manufacturer.
Faulty valve
In case of actuator mounted over the valve, check the valve documentation
and contact the manufacturer.
Incomplete rotation
Incorrect stroke adjustment
Follow the indications in section 9.5.8 for correct stroke adjustment.
Foreign object left inside
Disassemble the actuator, inspect and remove any foreign object.
Incorrect assembly after maintenance
Disassemble and reassemble the actuator correctly.
Hydraulic circuit blocked, compressed or
with speed control valve problems
Check all the tubing and
fi
ttings, remove any foreign object/damaged compo-
nent.
Control system
Make sure the control system components are correctly assembled. Check the
control system documentation and contact the manufacturer.
Faulty valve
In case of actuator mounted over the valve, check the valve documentation
and contact the manufacturer.
Loss of power
Inadequate supply pressure
Check the control system and make sure that the supply pressure is correct.
Supply pipe blocked, compressed or with
sealing problems
Check all the tubing and
fi
ttings, remove any foreign object/damaged compo-
nent.
Actuator seals leakage
Disassemble the actuator, inspect and replace any damaged seals.
blocked air exhaust hole
Remove plugs or foreign objects from the exhaust hole.
Faulty valve
In case of actuator mounted over the valve, check the valve documentation
and contact the manufacturer.
Uneven deceleration
Missing hydraulic oil
Make sure the HCD chambers bodies are correctly
fi
lled.
−
Contact PFEIFFER after-sales service for malfunctions not listed
in the table.
−
Spare parts are to be ordered with all information acc. to the
identi
fi
cation of the actuator. Only original parts from PFEIFFER
Chemie-Armaturenbau GmbH may be installed.
8.2 Emergency
action
The plant operator is responsible for emergency action to be tak-
en in the plant.
Note
Содержание EB 31a-23
Страница 14: ...3 4 EB 31a 23_EN Edition November 2021 Specifications subject to change Design and principle of operation...
Страница 20: ...5 4 EB 31a 23_EN Edition November 2021 Specifications subject to change Mounting and assembly...
Страница 22: ...6 2 EB 31a 23_EN Edition November 2021 Specifications subject to change Start up...
Страница 24: ...7 2 EB 31a 23_EN Edition November 2021 Specifications subject to change Operation...
Страница 26: ...8 2 EB 31a 23_EN Edition November 2021 Specifications subject to change Malfunctions...
Страница 42: ...9 16 EB 31a 23_EN Edition November 2021 Specifications subject to change Service...
Страница 44: ...10 2 EB 31a 23_EN Edition November 2021 Specifications subject to change Decomissioning...
Страница 48: ...12 2 EB 31a 23_EN Edition November 2021 Specifications subject to change Repairs...
Страница 50: ...13 2 EB 31a 23_EN Edition November 2021 Specifications subject to change Disposal...
Страница 52: ...14 2 EB 31a 23_EN Edition November 2021 Specifications subject to change Certificate...
Страница 53: ...14 3 EB 31a 23_EN Edition November 2021 Specifications subject to change Certificate...
Страница 54: ...14 4 EB 31a 23_EN Edition November 2021 Specifications subject to change Certificate...
Страница 61: ...EB 31a 23_EN Edition November 2021 Specifications subject to change...
Страница 62: ...EB 31a 23_EN Edition November 2021 Specifications subject to change...
Страница 63: ...EB 31a 23_EN Edition November 2021 Specifications subject to change...