18
Charge voltage is too low.
The charge voltage is being
compensated by the battery
temperature sensor to
protect the battery.
Do nothing or try to
cool down the ambient
temperature around the
battery.
Wrong battery type selected,
or charge voltage needs to be
adjusted.
Select the correct battery
type or adjust the charge
voltage in the setup menu.
DC cables too thin.
Install larger DC cables. See
the DC cable size table in
chapter 2.3.
Battery load current is higher
than the charger’s output
current.
Reduce or remove the
battery load.
LEDs blink red.
Error detected.
Check LED error table in
chapter 3.4.
If none of the above remedies will help solving the problem you encounter, it’s best to contact
your local Samlex distributor for further help and/or possible repair of your Elogic DC unit.
Do not disassemble the charger yourselves as this will void your warranty.
5. TECHNICAL SPECIFICATIONS
Parameter
EL 12-12/50
EL 12-24/50
Nominal input voltage
12Vdc
Input voltage range
10.0 – 16.0Vdc
Maximum input current
65Adc
Current consumption (inactive)
< 0.25mA
Current consumption
(noload/standby)
< 35mA
< 45mA
Nominal output voltage
12Vdc
24Vdc
Output voltage range
12.0 – 16.0Vdc
24.0 – 32.0Vdc
Maximum output current ¹⁾
50A
30A
Charge characteristic
IUoUo, intelligent 3-stage, temp. Compensated
Supported battery types ²⁾
Flooded / Gel / AGM / LiFePO4
Operating temperature range
-20°C ... +60°C
Storage temperature range
-30°C … +70°C
Содержание ELOGIC
Страница 2: ...2...
Страница 22: ...www samlex com www samlex solar com...