background image

15

start the charging process. There is however a second condition that must be met before the 
charger starts the charging process and this is the input voltage level. The input battery voltage 
must be above a certain level in order to allow the output battery to be charged. Additionally, 
this condition must also be met for a preset amount of time. Please see the table below 
showing all factory default voltage and time delay values that are stored inside the Elogic  
DC charger:

Parameter ¹⁾

Default value

EL 12-12/50

Default value

EL 12-24/30

Turn on input voltage

> 12.5V

> 12.5V

   Delay

10 sec

10 sec

Turn off input voltage (slow)

< 12.4V

< 12.4V

   Delay

3 min

3 min

Turn off input voltage (fast)

< 12.0V

< 12.0V

   Delay

1 sec

1 sec

¹⁾ All parameters are configurable using the Samlex Dashboard and Dashboard Mobile apps.

As can be seen in the above table, there are two low input voltage turn off levels. The ‘slow’ off 
level is allowed to be exceeded for a longer time than the ‘fast’ off level. This results in a stable 
charge process while still avoiding a too deeply discharged input battery.

CAUTION

If the main On/Off control input is connected to the ignition- instead of an engine running 
signal, while the turn off input voltage levels are set to relatively low values, please make sure 
to start the engine in a timely manner to avoid discharging the starter battery too much.

3.3 

Charger operation without using the main On/Off control input

When there is no engine run signal available or when the charger must always remain 
activated, DIP switch 4 must be set to ON. In this mode however, the input voltage 
requirements as shown in the table of chapter 3.2 still applies. So the charger will only start 
charging when these requirements are met.

CAUTION

Please be aware that in this always on mode, the charger will continue to draw a small  
current (< 35mA) from the input battery, even when the turn on input voltage condition 
has not been met. This could result in a discharged input battery if allowed for an extended 
amount of time.

Содержание ELOGIC

Страница 1: ...INTELLIGENT DC DC BATTERYCHARGER ELOGIC Owners Manual Please read this manual before operating your Elogic Batterycharger Model No EL 12 12 50 12V 50A EL 12 24 30 24V 30A...

Страница 2: ...2...

Страница 3: ...ES COSTS OR EXPENSES WHETHER SPECIAL DIRECT INDIRECT CONSEQUENTIAL OR INCIDENTAL WHICH MIGHT ARISE OUT OF THE USE OF SUCH INFORMATION THE USE OF ANY SUCH INFORMATION WILL BE ENTIRELY AT THE USER S RIS...

Страница 4: ...2 3 Wiring details 8 3 GENERAL FUNCTIONALITY 14 3 1 The charging process 14 3 2 Charger operation using the main On Off control input 14 3 3 Charger operation without using the main On Off control in...

Страница 5: ...the output battery voltage An Elogic DC charger allows the auxiliary battery to be perfectly charged regardless of the input voltage while being protected against damage due to peak voltages The Elogi...

Страница 6: ...losive gases DO NOT smoke or have an open spark or fire near the system 7 Never attempt to re charge a damaged frozen or non rechargeable battery 8 Keep unit away from moist or damp areas 9 Avoid drop...

Страница 7: ...se an appropriate mounting location in a well ventilated room that is protected against rain snow spray vapour moisture and dust 2 Make sure that the ambient temperature is between 20 C and 60 C Above...

Страница 8: ...user safety during installation please make sure that the output of the supplying source is switched off temporary remove fuses from the fuseholders and that no consumers are connected to the batteri...

Страница 9: ...r grommets over these cables like shown in the next image When the DC cables are connected to the charger the rubber grommets can be slid towards the charger s front panel until the screw connections...

Страница 10: ...ntly sized for the expected current Always keep the cable length as short as possible Model Minimum Cable size Recommended Cable size Battery fuse quick type EL 12 12 50 16mm AWG6 25mm AWG4 70 90Amp E...

Страница 11: ...de In this mode the charger stops charging but the internal circuits stay active to immediately resume charging once allowed again This input can be used to connect to a Lithium battery BMS in order t...

Страница 12: ...age 13 6V 27 2V On On LiFePo4 Bulk Abs voltage 14 4V 28 8V Float voltage 13 8V 27 6V DIP switch 3 is reserved for future use default off DIP switch 4 can be used to bypass the On Off control input see...

Страница 13: ...that is being charged output battery The charger automatically compensates the charge voltages against battery temperature This means that the charge voltages are slightly increased at lower temperat...

Страница 14: ...charge When the charge current has dropped below a certain value the Float stage will be entered For lithium batteries more than 80 of charge has been returned to the battery already So for this chem...

Страница 15: ...allowed to be exceeded for a longer time than the fast off level This results in a stable charge process while still avoiding a too deeply discharged input battery CAUTION If the main On Off control i...

Страница 16: ...Error see LED error table below Output LED Off Charger off or charging still blocked by input conditions not being met Flashing green Charging in progress Continuous green Charging finished Float sta...

Страница 17: ...capacity Incorrect absorption charge voltage setting Check the battery type selection for correct setting Or adjust the absorption voltage Incorrect charge current setting Make sure that the maximum...

Страница 18: ...4 If none of the above remedies will help solving the problem you encounter it s best to contact your local Samlex distributor for further help and or possible repair of your Elogic DC unit Do not di...

Страница 19: ...ctions 3x M6 screw terminal Enclosure body size HxWxD 70 x 128 x 170mm Total weight 1 2kg Protection class IP21 Standards EMC 2014 30 EU Low voltage directive 2014 35 EU RoHS 2011 65 EU Automotive EN5...

Страница 20: ...roduct and product malfunctioning Since Samlex cannot control the use and installation according to local regulations of their products the customer is always responsible for the actual use of these p...

Страница 21: ...y charger MODELS EL 12 12 50 EL 12 24 30 Conforms to the requirements of the following Directives of the European Union EMC Directive 2014 30 EU Low voltage Directive 2014 35 EU Automotive Directive 2...

Страница 22: ...www samlex com www samlex solar com...

Отзывы: