10
CAUTION
Double check for correct polarity, before connecting the battery cables to the battery!
Wrong polarity will blow an internal fuse and the charger must be returned for service.
Always keep positive and negative cables close to each other to minimize electromagnetic fields.
➀
Please consult the following table to determine the correct input battery cable- and fuse
size for each model. Using a smaller cable size will cause additional losses and may result in
improperly charged batteries. Fire and burning hazards are present if the battery cables are
insufficiently sized for the expected current. Always keep the cable length as short
as possible!
Model
Minimum Cable size
Recommended
Cable size
Battery fuse
(quick type)
EL 12-12/50
16mm² (AWG6)
25mm² (AWG4)
70-90Amp
EL 12-24/30
16mm² (AWG6)
25mm² (AWG4)
70-90Amp
➁
Please consult the following table to determine the correct output battery cable- and fuse
size for each model. Using a smaller cable size will cause additional losses and may result
in improperly charged batteries. Fire and burning hazards are present if the battery cables
are insufficiently sized for the expected current. Always keep the cable length as short
as possible!
Model
Minimum Cable size
Recommended
Cable size
Battery fuse
(quick type)
EL 12-12/50
16mm² (AWG6)
25mm² (AWG4)
60-80Amp
EL 12-24/30
10mm² (AWG8)
16mm² (AWG6)
40-50Amp