6. WARRANTY CONDITIONS

Samlex Europe (Samlex) warrants this product to be free from defects in workmanship or 
materials for 24 months from the date of purchase. During this period Samlex will repair the 
defective product free of charge. Samlex is not responsible for any costs of the transport of  
this product.

This warranty is void if the product has suffered any physical damage or alteration, either 
internally or externally, and does not cover damage arising from improper use, or from use  
in an unsuitable environment.

This warranty will not apply where the product has been misused, neglected, improperly 
installed or repaired by anyone other than Samlex. Samlex is not responsible for any loss, 
damage or costs arising from improper use, use in an unsuitable environment, improper 
installing of the product and product malfunctioning.

Since Samlex cannot control the use and installation (according to local regulations) of their 
products, the customer is always responsible for the actual use of these products. Samlex 
products are not designed for use as cricital components in life support devices or systems, 
that can potentially harm humans and/or the environment. The customer is always responsible 
when implementing Samlex products in these kind of applications. Samlex does not accept any 
responsibility for any violation of patents or other rights of third parties, resulting from the  
use of the Samlex product. Samlex keeps the right to change product specifications without 
previous notice.

Examples of improper use are:
- Too high AC input voltage applied
- Reverse connection of battery polarity
- Connecting wrong batteries (too high battery voltages)
- Mechanical stressed enclosure or internals due to harsh handling or incorrect packaging
- Contact with any liquids or oxidation caused by condensation

Содержание ELOGIC

Страница 1: ...INTELLIGENT DC DC BATTERYCHARGER ELOGIC Owners Manual Please read this manual before operating your Elogic Batterycharger Model No EL 12 12 50 12V 50A EL 12 24 30 24V 30A...

Страница 2: ...2...

Страница 3: ...ES COSTS OR EXPENSES WHETHER SPECIAL DIRECT INDIRECT CONSEQUENTIAL OR INCIDENTAL WHICH MIGHT ARISE OUT OF THE USE OF SUCH INFORMATION THE USE OF ANY SUCH INFORMATION WILL BE ENTIRELY AT THE USER S RIS...

Страница 4: ...2 3 Wiring details 8 3 GENERAL FUNCTIONALITY 14 3 1 The charging process 14 3 2 Charger operation using the main On Off control input 14 3 3 Charger operation without using the main On Off control in...

Страница 5: ...the output battery voltage An Elogic DC charger allows the auxiliary battery to be perfectly charged regardless of the input voltage while being protected against damage due to peak voltages The Elogi...

Страница 6: ...losive gases DO NOT smoke or have an open spark or fire near the system 7 Never attempt to re charge a damaged frozen or non rechargeable battery 8 Keep unit away from moist or damp areas 9 Avoid drop...

Страница 7: ...se an appropriate mounting location in a well ventilated room that is protected against rain snow spray vapour moisture and dust 2 Make sure that the ambient temperature is between 20 C and 60 C Above...

Страница 8: ...user safety during installation please make sure that the output of the supplying source is switched off temporary remove fuses from the fuseholders and that no consumers are connected to the batteri...

Страница 9: ...r grommets over these cables like shown in the next image When the DC cables are connected to the charger the rubber grommets can be slid towards the charger s front panel until the screw connections...

Страница 10: ...ntly sized for the expected current Always keep the cable length as short as possible Model Minimum Cable size Recommended Cable size Battery fuse quick type EL 12 12 50 16mm AWG6 25mm AWG4 70 90Amp E...

Страница 11: ...de In this mode the charger stops charging but the internal circuits stay active to immediately resume charging once allowed again This input can be used to connect to a Lithium battery BMS in order t...

Страница 12: ...age 13 6V 27 2V On On LiFePo4 Bulk Abs voltage 14 4V 28 8V Float voltage 13 8V 27 6V DIP switch 3 is reserved for future use default off DIP switch 4 can be used to bypass the On Off control input see...

Страница 13: ...that is being charged output battery The charger automatically compensates the charge voltages against battery temperature This means that the charge voltages are slightly increased at lower temperat...

Страница 14: ...charge When the charge current has dropped below a certain value the Float stage will be entered For lithium batteries more than 80 of charge has been returned to the battery already So for this chem...

Страница 15: ...allowed to be exceeded for a longer time than the fast off level This results in a stable charge process while still avoiding a too deeply discharged input battery CAUTION If the main On Off control i...

Страница 16: ...Error see LED error table below Output LED Off Charger off or charging still blocked by input conditions not being met Flashing green Charging in progress Continuous green Charging finished Float sta...

Страница 17: ...capacity Incorrect absorption charge voltage setting Check the battery type selection for correct setting Or adjust the absorption voltage Incorrect charge current setting Make sure that the maximum...

Страница 18: ...4 If none of the above remedies will help solving the problem you encounter it s best to contact your local Samlex distributor for further help and or possible repair of your Elogic DC unit Do not di...

Страница 19: ...ctions 3x M6 screw terminal Enclosure body size HxWxD 70 x 128 x 170mm Total weight 1 2kg Protection class IP21 Standards EMC 2014 30 EU Low voltage directive 2014 35 EU RoHS 2011 65 EU Automotive EN5...

Страница 20: ...roduct and product malfunctioning Since Samlex cannot control the use and installation according to local regulations of their products the customer is always responsible for the actual use of these p...

Страница 21: ...y charger MODELS EL 12 12 50 EL 12 24 30 Conforms to the requirements of the following Directives of the European Union EMC Directive 2014 30 EU Low voltage Directive 2014 35 EU Automotive Directive 2...

Страница 22: ...www samlex com www samlex solar com...

Отзывы: