Revision index : C - 1/29/97
- 10 -
Code : RT 6076
MAINTENANCE FREQUENCY
4 - MAINTENANCE
4.1 - PERIODICAL MAINTENANCE AND CHECK-UPS
IMPORTANT : All cleaning work should be carried out using compressed air, rags or if necessary
brushes.
Water should NEVER be used.
Spray gun soiling and wear, caused by powder flow, clearly depends on the type of powder used.
The guidelines as to cleaning and maintenance frequency provided in the table below can only be
taken as an indication of what is required.
Users of SAMES equipment should develop their own maintenance programmes.
As a first approach we recommend the following programme :
ACTION
• Before starting work.
• Every day.
• Between 150 and 300 hours (or more).
• Check rules 3, 4 and 6 of section 2.1.
• Remove the nozzles from the SRV 028 spray
gun and clean the electrode with a brush.
• Clean the nozzles with compressed air.
• Replace the nozzle if grooves are visible inside
nozzle.
4.2 - DISMANTLING AND RE-ASSEMBLY (GENERAL)
Dismantling and re-assembly of these complex assemblies are described in Chapter 6.
Easy and frequent component dismantling :
• SRV 028 spray gun (refer to plate BF4-1).