Code : RT 6076
3 - COMMISSIONING
3.1 - PREPARING THE SPRAY GUN
(Refer to Fig.4)
•
Fasten the socket [1] of the electrical power supply cable onto the fixed flange [2]. Check
socket orientation (contact marks in front of plug contacts of plug [3] installed in the mobile
flange [4].
•
Connect the pneumatic and powder feed pipes onto the fixed flange [2]. Fasten the fixed flange
onto the adapter flange [5].
3.2 - OPERATION AND SETTINGS
The SRV 028-2-Twin 60
°
powder spray gun should be installed 150 to 300 mm from the part to be
painted.
Voltage adjustments are described in the instructions manual of the GND 504-B control unit (see
RT 6017 manual).
CAUTION : Current consumption with the SRV 028-2-Twin 60
°
spray gun should never
exceed 30
µ
A per gun (i.e. 60
µ
A for two guns) during spraying. Higher current
consumption would result in fouling of the electrode and will cause loss of
efficiency of the spray gun.