background image

14  

  Introduction 

SPS-500 Program Manual v1.31 

 

Connection Panel 

Standard ports include:  

 

2 Additional Cash Drawer Ports (24v) 

 

LAN port 

 

2-USB Ports (1 back panel/1 front) 

 

4-RS-232C Comm. Ports (2-DB9 Male/2-RJ45) 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Serial Number/

Identification

Label

Front USB port 

located behind access 

door (for keyboard, 

USB memory stick or 

scanner)

Содержание SPS-500

Страница 1: ...SPS 500 Series Program Reference Manual All specifications are subject to change without notice 2014 CRS Inc PM SPS 500 manual version 1 31...

Страница 2: ...S THESE PRODUCT S CRS INC SPECIFICALLY DOES NOT WARRANT THAT THE OPERATION OF ANY DRIVERS SOFTWARE OR PROGRAMMING PRODUCTS LICENSED HEREUNDER WHETHER EMBEDDED IN PRODUCTS OR PROVIDED AS SEPARATE PROGR...

Страница 3: ...ially the AC and high voltage supplies Always inspect for pinched out of place or frayed wiring Do not change the spacing between comp onents and the printed circuit board Check the AC power cord for...

Страница 4: ...instrument chassis ground before connecting the positive lead always remove the instrument s ground lead last 1 3 Precautions for Electrostatically Sensitive Devices ESDs 1 Some semiconductor solid s...

Страница 5: ...520RT SPS 530RT 17 Expanded Raised Key Keyboard SPS 520RT SPS 530RT 17 Default Screen Layout 18 Screen Saver 18 X Mode Main Menu 19 Z Mode Main Menu 19 P Mode Main Menu 20 S Mode Main Menu 20 Keylinks...

Страница 6: ...57 Printer Driver Selections 61 Printer Driver Definitions 61 Define Port 62 Define Port Definitions 62 S Mode Program Scan Printing 64 S Mode Program Scans Definitions 64 Password Notes 65 Load Defa...

Страница 7: ...Custom Report 132 Financial Report Employee Report 133 String Report 133 Time 134 Time Period 134 Time Activated Functions 134 Sending Time Activated String Reports to an FTP Site 135 Product Ingredie...

Страница 8: ...m Manual v1 31 Balancing Formulas 165 Appendix 167 Report Function Key Report Code Structure 167 Report Table 167 Report Option Table 170 Special Report Commands 170 Glossary of Terms 171 Index 179 Ma...

Страница 9: ...rovide detailed power specifications for these applications Failure to implement installation requirements for networked systems may cause system failures and or poor system performance The SAM4s SPS...

Страница 10: ...sing the SAM4s SPS 500 for the first time leave it powered on in the REG key lock position for at least twenty four hours This allows the Ni MH battery which maintains the memory of the ECR while the...

Страница 11: ...nsion Software The built in SPS 500 POS application has considerable flexibility and can be configured for both retail sales and food sales in quick and table service environments The SPS 500 applicat...

Страница 12: ...Adjustment Optional Magnetic Card Reader MCR Power Switch Set the LCD panel to the optimum viewing angle The Power LED will illuminate when the ECR is powered on The IRC LED will flash during IRC ope...

Страница 13: ...Rear Display Turn and or lift for optimum viewing with nearly 360 turning radius The Standard SPS 500 SD Memory Card slot is located inside the printer compartment It can be used to Load Application P...

Страница 14: ...el Standard ports include 2 Additional Cash Drawer Ports 24v LAN port 2 USB Ports 1 back panel 1 front 4 RS 232C Comm Ports 2 DB9 Male 2 RJ45 Serial Number Identification Label Front USB port located...

Страница 15: ...ister reports and perform other manager functions Use to read register reports and reset totals to zero Program Use to program the register Use for tests and special settings This position is not mark...

Страница 16: ...O 3 FOR PLU CLEAR MISC2 6 15 24 34 44 54 64 74 84 94 104 1 7 8 9 MISC 1 7 16 25 35 45 55 65 75 85 95 105 2 4 5 6 CHECK 8 17 26 36 46 56 66 76 86 96 106 3 1 2 3 SBTL 9 18 27 37 47 57 67 77 Pt 87 96 10...

Страница 17: ...1 RECT FEED RCPT ISSUE DETL FEED MACRO 3 MACRO 2 MACRO 1 0 CASH 00 7 12 6 11 8 13 9 14 10 15 3 YES NO X TIME CHECK F S TEND CLEAR PLU 14 2 1 3 4 5 7 12 6 11 8 13 9 10 15 17 16 18 19 20 22 21 23 24 25...

Страница 18: ...play Transaction Detail is displayed here If over 20 items are displayed on the default screen a scroll bar displays Note that the transaction area may be oriented to the left or right of the screen M...

Страница 19: ...v1 31 Introduction 19 X Mode Main Menu Note X Mode Menu buttons are not active until a clerk is signed on in REG position Z Mode Main Menu Note Z Mode Menu buttons are not active until a clerk is sig...

Страница 20: ...roduction SPS 500 Program Manual v1 31 P Mode Main Menu Note P Mode Menu buttons are not active until a clerk is signed on in REG position S Mode Main Menu Note S Mode Main Menu was updated at version...

Страница 21: ...y condiments instructions or options for an item registered from the main keyboard They may also be used to organize function keys such as discounts or type of payment keys Keylinks can display any co...

Страница 22: ...key locations in a 4 x 6 matrix Note Four screen configuration options are available providing 24 12 6 or 0 key locations on the display Large wide and vertical keys may be used and unused locations m...

Страница 23: ...memory areas and installation of the default program can be done through the following special procedure 1 Turn the power switch located on the right side of the register to the OFF position 2 Turn th...

Страница 24: ...play will monitor the memory clear process which takes about 1 minute 7 When complete the display will prompt Enter Register Number 1 32 Type the register number on the numeric keypad and touch OK 8 W...

Страница 25: ...and software update information Verify that the same software version is installed on all terminals in a multi terminal installation Important Updating Existing Installations If you are performing an...

Страница 26: ...This program will be frequently updated as features and operations are changed Do not confuse the application program with the end user program which consists of the files and setting prepared for an...

Страница 27: ...SH key is located on the default keyboard layout 4 Continue to hold the default CASH key location while turning the power switch to the ON position Hold the key until a short double beep is heard 5 Pr...

Страница 28: ...mplete test Etc Displays test results for Nand Flash SD card MSR track 1 3 MICOM version displays cash drawer and printer status RTC Read Display current YYYY MM DD time and day of week Write Set YYYY...

Страница 29: ...See Downloading Logo Images for the Internal Printer on page 35 for more information Printer Density Set internal printer density Low Mid High Select KBD Select Flat 160 or Raised 90 keyboard must ma...

Страница 30: ...all memory after any update This utility allows you to upgrade or back up the SPS 500 application program a file in the sps500 folder named sps500 using either an SD card or USB memory stick The appli...

Страница 31: ...E menu returns and the backup is complete Do not power off the ECR or attempt another operation until the S Mode menu returns After completion it is not necessary to clear memory If you are completing...

Страница 32: ...firmation displays 6 If you wish to capture multiple screens press F5 for each screen you wish to capture Be sure to wait until the confirmation dialog displays before attempting another screen captur...

Страница 33: ...re size larger images Images in many common formats can be used i e gif tif jpeg bmp wmf format images cannot be used The length of the image file name must be less than 12 characters The image size f...

Страница 34: ...nter compartment of the SPS 500 3 Select KEY RELOCATION and then SCREEN DESIGNER from the P or S Mode menu Select the PGM tab 4 Touch the Image key 5 The Button Image Select dialog box displays Touch...

Страница 35: ...he new image s will replace the SAM4s logo as the screen saver Downloading Logo Images for the Internal Printer You can load up to 14 images into SPS 500 memory through the SD card for printing on the...

Страница 36: ...36 Software Installation SD Utilities SPS 500 Program Manual v1 31...

Страница 37: ...ctions The procedures described in this area are security sensitive Many S Mode functions including memory clearing and memory allocation may cause damage or loss if they are performed without first b...

Страница 38: ...s will test both reading and writing of the Random access memory NOTE This test is non destructive Performing this test will not affect the current program or totals IRC This will test the Ethernet in...

Страница 39: ...reporting memory clearing all totals including grand totals 2 CLEAR TOTALS AND COUNTERS This will clear all sales totals from the reporting memory excluding grand totals 3 CLEAR GRAND TOTALS ONLY This...

Страница 40: ...rom the file leaving on the basic program 14 CLEAR ELECTRONIC JOURNAL This will reset all sales data held within the electronic journal without printing 15 CLEAR CONSECUTIVE This will reset the receip...

Страница 41: ...zes for the ECR once they have been entered they are fixed and cannot be changed without program resetting the machine All ECRs within an IRC inter register communications system should have identical...

Страница 42: ...R FULL will display and the transaction must be finalized Note Must be greater than or equal to the number of lines per soft check Note that voided items also use lines in a check 11 OF LINES PER CHEC...

Страница 43: ...ceipt reprint options 20 OF PAID RECALL TRANSACTIONS Enter the number of preceding transactions a maximum of 99 that may be viewed by repeatedly pressing the PAID RECALL key 21 CLERK INTERRUPT This en...

Страница 44: ...500 applications will be designed with menu items located on the traditional keyboard and condiments options and instructions displayed on the screen About Keylinks Keylinks may be used to organize f...

Страница 45: ...Y RELOCATION and then SCREEN DESIGNER from the S menu The KEY RELOCATION screen displays with the SCREEN tab selected 2 Use the or keys to select the keylink screen you wish to program or touch the bu...

Страница 46: ...LIST KEY LINK field set the NUMBER OF CHOICE field to a value of 99 If YES the keylink will ask for the quantity of items The DISPLAY BACKGROUND IMAGE option you must also download the image See Imag...

Страница 47: ...ocation Touch the FUNCTON tab and then select the function from the list or Touch the MACRO tab to assign a macro to the location or Touch the PLU tab to assign a PLU to the location or Touch the KEY...

Страница 48: ...71 SERV DELIVERY 72 DELIVERY LIST 73 Reserved 74 Reserved 75 Reserved 76 Reserved 77 DATATRAN 78 STRING REPORT 79 NEXT DOLLAR 80 SHIFT CHANGE 81 Reserved 82 Reserved 83 Reserved 84 Reserved 85 Reserv...

Страница 49: ...5 RECD ACCT 5 206 RECEIPT 207 REPEAT 208 SCALE 209 SEAT 210 Reserved 211 SPLIT ITEM 212 SPLIT PAY 213 STOCK INQ 214 STORE CHK1 215 STORE CHK2 216 STORE CHK3 217 STORE CHK4 218 SUBTOTAL 219 TABLE 1 220...

Страница 50: ...sory check endorsement is set with the CHECK key use the CHECK ENDORSE key to print the endorsement message after a check is inserted into the appropriate printer CLEAR 024 Use the CLEAR function to c...

Страница 51: ...n LIST CHECK 1 4 064 067 Touch LIST CHECK for the appropriate tracking file to display a list of all open soft checks in the file DELIVERY 069 The Delivery function key is used to initiate a delivery...

Страница 52: ...ering the macro number and touching the MACRO key MDSE RETURN 118 Touch the MDSE RETURN key to adjust items inside or outside of a transaction MISC TEND 1 16 119 134 Touch a MISC TEND key to finalize...

Страница 53: ...key to be touched every time the menu item is sold This function does not affect normal kitchen printer KVS routing The PRINT function also sends items in group sequence using the meal order feature I...

Страница 54: ...e assigned at the time of entry or if necessary later in the transaction SPLIT ITEM 211 When like items are consolidated in a transaction you can move the cursor to the item and touch the SPLIT ITEM k...

Страница 55: ...a specific Key Link Enter the Key link 1 200 touch the FUNC LIST key X TIME 244 Use the X TIME key to multiply to register split price items or display the time in the REG mode 245 Reserved PARK ORDE...

Страница 56: ...items are to be assigned enter the number of the new check you previously created ALPHA TEXT 250 Use to type a name or message that will be associated with a soft check Touch the ALPHA TEXT key anyti...

Страница 57: ...e first ECR in an inter register communications system The norm is 1 4 IRC TO REGISTER This is the number for the last ECR in an inter register communications system 5 IRC NUMBER OF RETRIES The standa...

Страница 58: ...S THE DATATRAN Enter the number of the ECR in the network where the DataTran is connected 16 MSR IS CONNECTED Set MSR CONNECTED to DATATRAN if the MSR is connected to the DATATRAN PDC if the MSR is co...

Страница 59: ...drawer opening failure 23 DRAWER OPEN TIME Default is 200 This is the length of the drawer pulse Set this option only if you are experiencing intermittent cash drawer opening failure 24 STRONG PASSWOR...

Страница 60: ...nks cannot be used when FULL SCREEN is selected 28 DATATRAN TIMEOUT 30 240 option added at version 1 00q Set to 240 when using integrated electronic payments Datatran Lower settings may cause payment...

Страница 61: ...cation The system does have some custom printer types available for technicians to allocate their own settings PRINTER TASKS INITIALIZE COMPRESS Etc Leave these setting at default unless specific sett...

Страница 62: ...ally supplied with the device DATA BITS This is a standard peripheral definition the information is normally supplied with the device STOP BITS This is a standard peripheral definition the information...

Страница 63: ...ich are pre programmed with Driver setting VIDEO This is a linked Kitchen Video System for the display of products POLLING This is the on line computer link SCALE This links to an approved scale for w...

Страница 64: ...orts communication speed and unique settings SUPER MACRO The supermacro a troubleshooting resource records the last 1000 keystrokes in REG mode keystroke in other modes are not recorded When 1000 keys...

Страница 65: ...MESSAGES These are the onscreen display prompts warning the operator of miss operations Default Error Messages are listed on page 141 SYSTEM DESCRIPTORS These are the onscreen and reporting messages d...

Страница 66: ...he SPS 500 to the FTP site via a router and internet connection then touch the appropriate button to display the select store name field dialog box 3 If you are saving a store s program for the first...

Страница 67: ...uch YES The PLEASE WAIT message displays until the download is complete Restore End User Program 1 Insert the memory device containing the program in the SPS 500 2 From the S Mode menu touch SRAM Back...

Страница 68: ...store name dialog box select the name of the store 4 Touch OPEN The SRAM BACKUP SD dialog box displays 5 Touch SAVE REPORT TO SD 6 At the Confirmation dialog box touch YES The PLEASE WAIT message dis...

Страница 69: ...s capability contact CRS for demonstration documentation 1 Select SRAM BACKUP from the S Mode menu 2 Touch FTP TRANSMISSION Enter the information for the FTP site you are connecting to 3 Touch CONNECT...

Страница 70: ...70 S Mode Programming SPS 500 Program Manual v1 31...

Страница 71: ...SPS 500 Program Manual v1 31 P Mode Programming 71 P Mode Programming P Mode Programming Menu Turn the key lock to the P position...

Страница 72: ...signed to a product Separate PLU Status Groups are defined to accommodate the needs of groups of PLUs Like PLUs the total number of PLU Status Groups is determined by memory allocation The maximum num...

Страница 73: ...Key Link where you wish to edit a PLU displays Press a PLU key on the main keyboard Enter the PLU number and touch OK You can add new PLUs in one of two ways New PLUs that are to be located the MAIN S...

Страница 74: ...without regard to brand such as cigarette packs MODIFIER QTY This works in conjunction with the stock link PLU flag determining how many units are to be reduced from the main stock item The field con...

Страница 75: ...aining accumulated product sales data PRESET This determines whether the product is a pre set or open price ALLOW PRICE CHANGE If yes the PLU price can be changed in REG mode with the sequence PRICE C...

Страница 76: ...selection window 2 Touch PLU DELETE 3 To delete PLUs individually touch PLU DELETE BY ONE to display the SELECT PLU screen Identify a PLU by touching a key or by entering a PLU number a touching OK T...

Страница 77: ...etermined by memory allocation 1 From the P mode menu touch PLU to view the PLU program selection window 2 Touch PLU STATUS GROUP to view the PLU STATUS GROUP PROGRAMMING screen 3 Touch the PLU STATUS...

Страница 78: ...as the price per gallon The price is set at three decimal places however the PLU programming screen will always display in a two digit decimal format For example if a PLU is gallonage a price of 1 29...

Страница 79: ...you wish to allow the PROMO operation i e buy two get one free PROMO activity will remove the item cost from the sale but the count will include the promo item 20 ALLOW WASTE If Yes the WASTE functio...

Страница 80: ...PRINT ON GUEST CHECKS Must be set to Yes for PLUs in this group to print on the guest check 36 PRINT PRICE ON GUEST CHECKS Prints the descriptor only rather than descriptor and price on guest checks...

Страница 81: ...rator will be forced to enter a date of birth that indicates an age higher than the age of 83 to set the minimum age for each of up to 5 categories 44 IS PLU GIFT CARD Default is NONE Select ACTIVATE...

Страница 82: ...UPCs using the EAN 13 code with embedded prices or weights Within the EAN 13 code the first two digits part a are used as an identifier and the last digit part c is used as a check digit The remaining...

Страница 83: ...FIELD 2 Assign the length of the price weight quantity field The length of field 1 plus field 2 must equal 10 CONTENT OF FIELD 2 Select the type of content for field 2 price weight or quantity USE PRI...

Страница 84: ...items controlled at a different age i e alcohol may be allowed at age 21 and tobacco may be allowed at age 18 up to five different ages can be entered here The age category 1 5 is entered at the appr...

Страница 85: ...determine the track where the date is located track 1 or track 2 3 Determine the format of the date i e YYYYMMDD Added at V1 00m MMYYY99YY date format for California California must also choose 10 fo...

Страница 86: ...U from the P Mode menu and then from the PLU option menu touch PAGE DOWN to view and select the PLU QUICK REGISTRATION option A blank PLU QUICK REGISTRATION PROGRAM screen displays The screen command...

Страница 87: ...with PLU 1001 and range to PLU 1999 PLUs assigned to group 2 will range from 2001 2999 etc DESCRIPTOR Touch the current descriptor button to edit the descriptor field STOCK Select a PLU and touch STO...

Страница 88: ...si and Coke 2 Ice Cream items Cones and Malts Program these items using the Quick Registration method 1 Clear all PLU data Select MEMORY CLEAR from the S Mode menu then select option 13 CLEAR PLU FILE...

Страница 89: ...en displays 15 Touch YES The message Do You Want To Configure Printers displays If No is selected the register will not change Port Parameters and does not change KP Printer Routing 16 From the PGM me...

Страница 90: ...he drink items 19 Touch ICE CREAM to view the ice cream items The DRINKS key is Key Link function 077 Items linked to the DRINKS group display on Key Link screen 077 The ICE CREAM key is Key Link func...

Страница 91: ...low Touch another group Key Link to display its PLUs Up to eight groups can be displayed simultaneously When more that eight groups are used arrow keys display Touch the arrow down to display the next...

Страница 92: ...programmed with PLU STATUS GROUP 400 when only 200 PLU STATUS GROUPS are allocated in MEMORY ALLOCATION This feature will check the flags STOCK LINK PLU MODIFIER QTY GROUP PLU STATUS GROUP PIECE COUNT...

Страница 93: ...Group report 1 From the P Mode menu screen touch Group to display group program options 2 Touch Next Record or Prev Record to view the group you wish to program 3 Set the Descriptor and Add to Group T...

Страница 94: ...s on the financial or employee report See on page 120 to determine which descriptors are used on reports 1 Functions are on separate lists Functions Macros and Key links Select FUNCTION KEY from the P...

Страница 95: ...ECK X X X Exempt Tax 1 6 Open Drawer Compulsory Check Endorsement Amount Tender Compulsory Disable Under Tendering Manager required for under tendering Non add entry compulsory HALO Change Tender Coin...

Страница 96: ...int on KP Print on Receipt HOLD X X INACTIVE X LIST CHECK 1 4 X X DELIVERY X PARK DELIVERY X SERV DELIVERY X DELIVERY LIST X DATATRAN X STRING REPORT X X Use IRC NEXT DOLLAR X SHIFT CHANGE X ENTER X C...

Страница 97: ...of PLU NO SALE X X HALO Digits for Non Add Entry 0 14 Allow No Sale Function Allow Non Add Function No Sale in X Only No Sale Inactive After Non Add Entry Enforce Non Add at Beginning of Sale Comp No...

Страница 98: ...nal On KP Drive Thru Feature Enabled Print Receipt After Store Check Scan Check Length of Check in Digits 0 10 RECD ACCT 1 5 X X X X RECEIPT X Print REPRINT on Receipt REPEAT X X SCALE X X Allow Manua...

Страница 99: ...ID ITEM X X X X WASTE X X X Affect on Projections FUNC LIST X X TIME X Allow Split Pricing Allow Decimal Input PARK ORDER X X SERVE ORDER X X KP ROUTING X X Routing Period is Stay down Trans Pop Up SP...

Страница 100: ...y position For example you can enter 4 digits the decimal and four fractional digits CHANGE IN FOREIGN CURRENCY Select whether any change from an over tender is issued in foreign currency Y or home cu...

Страница 101: ...modifier key prior to the registration of PLU 17 will result in the registration of PLU 1017 Key Program Note KEY IS DO IT DISCOUNT FUNCTION If a tender is short of the amount due the operator has the...

Страница 102: ...s use of scanner to enter check number Note If check numbers are assigned by register the operator will be prompted to choose SCAN CHECK or OPEN A NEW CHECK when the RECALL CHECK key is touched Note P...

Страница 103: ...eferenced by number within each category for reference 1 Select SYSTEM OPTION from the P Mode menu to display the SYSTEM OPTION PROGRAMMING selection screen 2 Touch the System Option Programming area...

Страница 104: ...method for discount surcharge Up and 5 always up or always down 5 ROUNDING ON SPLIT PRICE DECIMAL MULT When calculations result in a fraction of a cent you have the option of rounding UP AT 5 0 005 o...

Страница 105: ...tiplier 12 ALLOW PLU PRESET HALO OVERRIDE Override of a preset entry of a price into a preset key or override of a HALO entry of a price greater than the PLUs high amount limit can be allowed Note In...

Страница 106: ...file the operator can enter the item price and complete the transaction 34 SET DEFAULT SEAT TO 1 If yes each item that does not receive a seat will be assigned the default seat number of 1 Using a se...

Страница 107: ...register 44 ALLOW CLERK CHANGE WITHOUT SIGN OFF If YES new clerk sign on is allowed without previously signing off the current employee Must be set to YES if clerk interrupt is implemented 45 SKIP IN...

Страница 108: ...e PLU STATUS GROUP option 16 a warning BELOW MINIMUM STOCK will display when if the PLU is registered and stock is below the minimum level 57 SCREEN SAVER TYPE Select FLOATING or ROTATE Floating requi...

Страница 109: ...UBTOTAL Option added at version 1 00s 2 4 2013 Choose YES to round cash transactions to the nearest 05 check misc tender transactions will not round Also set GENERAL FUNCTION OPTION 9 Tax Option Defin...

Страница 110: ...stamp indicator F S displays on the screen and prints on printers adjacent to the item Choose No to remove the indicator from the display and print 12 PRINT TAX ON VAT If Yes prints breakout tax amou...

Страница 111: ...R DISPLAY IN TRAINING Choose Yes to activate the rear display during training activity If No the rear display indicates CLOSED during training 4 SEND ORDER TO KP V IN TRAINING Choose Yes to send order...

Страница 112: ...nly once i e small med large If No several modifiers affecting different digit positions could be entered and then affect the PLU registered For example size crust type and or toppings could be indica...

Страница 113: ...0 See Memory Allocation in S Mode Programming 8 STARTING CHECK For each tracking file that you are using if you are automatically assigning tracking numbers you can enter the first number of the track...

Страница 114: ...printed before payment is tendered 27 PRINT DELIVERY INFO ON GUEST CHECK If yes delivery information name address etc from the customer delivery record will print on the check 28 PREVENT SALE OVER DE...

Страница 115: ...to the KVS when the subtotal key is pressed instead of when the sale is finalized 8 PRINT VOIDED ORDERS AT KP OR KVS If No then transaction void orders will not print or display at the appropriate pri...

Страница 116: ...E KV REFRESH If yes will delete all items from the KVS and re display them when a condiment is inserted or a void is performed Validation Subtotal Print Option Definitions NOTE To validate you must at...

Страница 117: ...LINES AFTER PREAMBLE Enter the number of lines you wish to feed after the preamble and before the first receipt print line 4 LINES BEFORE POSTAMBLE Enter the number of lines you wish to after the last...

Страница 118: ...o generate a receipt automatically when transactions are tendered 23 PRINT RECEIPT AFTER TIME CLOCK EDIT If Yes a receipt is printed whenever an employee s time is edited If Yes a counter of the numbe...

Страница 119: ...Image ON GUEST CHECK Select one of the loaded bit map images 37 POST LOGO Image ON GUEST CHECK Select one of the loaded bit map images 38 PRINT ERROR CORRECT VOID ON EJ PRINTER When set to YES error...

Страница 120: ...als for some function keys The descriptor that appears on the report can be the programmed function key descriptor or can be the report descriptor see Messages on page 141 8 PRINT MIN STK RPT AFTER FI...

Страница 121: ...gram Manual v1 31 P Mode Programming 121 15 DO NOT PRINT HASH SYMBOL 16 PRINT TIME ON REPORTS 17 PRINT OPEN CHECK TOTAL ON FIN REPORT 18 PRINT Z REPORT WHEN RCPT ON OFF KEY IS SET OFF v 1 00s 7 16 201...

Страница 122: ...on selected items 6 RESET PLU REPORT AT INVENTORY Z1 If Yes a Z1 PLU report will automatically be generated when an Inventory Z1 is taken 7 RESET INVENTORY REPORT AT PLU Z1 If Yes an Inventory Z1 will...

Страница 123: ...TIME PERIOD REPORT The Time period report feeds the totals for the SALES LABOR report This options allows the totals to be without tax 23 PLU COST PRICE LEVEL 0 20 If you wish to report PLU cost prof...

Страница 124: ...rnal Detail Printing Option Definitions 1 ACTIVATE ELECTRONIC JOURNAL Select Yes to activate the electronic journal 2 DISPLAY E J BUFFER FULL WARNING Select Yes to display a warning message when the e...

Страница 125: ...transaction listed select Yes or No to determine it will be sent to the appropriate detail journal printer Regardless of other settings will send only transactions with negative items entries any entr...

Страница 126: ...in or out and a separate sign on code used to operate the register The social security number is for reference only and appears only on reports The total number of employees up to 999 is set in memory...

Страница 127: ...each employee By assigning separate job codes and pay rates for each employee the built in time clock can track and report hours and wage costs appropriately See Time Clock Procedures in the SPS 500 O...

Страница 128: ...sible job codes Each job code you wish to activate must be given a descriptor here EDIT PAY RATES Note An employee with the appropriate authority level must be signed on to perform pay rate programmin...

Страница 129: ...OPEN CHKS 4 GUEST CHECK ENTRIES ONLY 5 PAYMENT OF OWN GUEST CHECK 6 PAYMENT OF ANY GUEST CHECK 7 TRANSFER OF GUEST CHECKS 8 VOIDING OF SERVICED ITEMS 9 ALLOW CANCEL AFTER RECALL 10 CLOCK IN OUT USING...

Страница 130: ...equired for integrated payment installations Groups By Employee If you choose to use groups by employee see Memory Allocation on page 41 you can select which of the 99 available groups are reported fo...

Страница 131: ...ber of the column that the Card number starts CARD NUMBER DIGITS Enter the number of digits to be read for the Card number Determining MCR Settings 1 Read data from a sample card using the SPS 2000 Se...

Страница 132: ...are also created in other words you can clear the custom reports independently without affecting totals in any other report Another feature of the custom report is the ability to add or subtract sele...

Страница 133: ...rt can be modified so that specific totals are deleted from the report or printed in red provided the printer is capable of 2 color print 1 From the PGM mode PROGRAMMING MENU touch REPORT to view the...

Страница 134: ...NU touch TIME to view the TIME selection window 2 Touch TIME PERIOD to view the TIME PERIOD PROGRAMMING screen 3 For each period you can adjust reporting times by touching the time and entering a new...

Страница 135: ...opriate network settings and identify the FTP server address These settings are found in a separate document titled SPS 2000 SPS 5X0 FTP Reports that is posted under Support Documents on the SPS 2000...

Страница 136: ...duct mix group time periods are also programmed set with this program If used The PLU Stock counters decrements for each activity in the PLU PLU stock is set in the PLU program see PLU Stock on page 8...

Страница 137: ...ample a special sauce a recipe may be an ingredient of a sandwich recipe Enter the 3 digit number of the recipe or ingredient DESCRIPTOR Display only When a recipe or ingredient number is entered the...

Страница 138: ...roup time periods will default to hourly periods if 24 periods are selected in memory allocation 30 minute periods if 48 periods are selected 15 minute periods if 96 periods are selected Periods can b...

Страница 139: ...ode PROGRAMMING MENU touch TAXES to view the TAX PROGRAMMING Screen 2 Touch the TYPE button to select ADD ON TAX TABLE or VAT 3 Refer to the notes that follow to program each type of tax 4 Touch CLOSE...

Страница 140: ...table for the tax you are programming 2 Examine the pattern of break point differences to determine when the break points begin to repeat Mark the beginning break points that do not fit a pattern as...

Страница 141: ...Validation Message 3 line x 40 character Prints when forms are validated on an optional slip printer DataTran Message 4 line x 32 character Prints on electronic payment voucher receipt Pole Display M...

Страница 142: ...LLOWED 97 WASTE NOT ALLOWED 98 NO FOOD STAMP AMOUNT 99 DECIMAL ENTRY NOT ALLOWED 100 SPLIT PRICING NOT ALLOWED 101 VOID MODE IS DEACTIVATED 102 JOB CODE REQUIRED 103 JOB CODE CHANGE NOT ALLOWED 104 PU...

Страница 143: ...OT ALLOWED 188 PLU NOT INCLUDED 189 NO RESPONSE RETRY 190 GIFT CARD DUPLICATED 191 DEVICE ALREADY OPENED 192 DEVICE OPEN ERROR 193 PASSWORD ERROR 194 NOTHING SELECTED 195 INVALID SD CARD 196 RESET REP...

Страница 144: ...S 66 REPORTS 67 PROGRAM SCAN 68 CHECK TRACKING 69 CLERK INTERRUPT 70 ALPHA TEXT 71 ENTER REGISTER 1 32 72 DOWNLOAD FILE 73 RESERVED 74 POWER FAIL COUNT 75 RESERVED 76 RESERVED 77 RESERVED 78 IP ADDRES...

Страница 145: ...MT 212 ENTER TIP AMT 213 GETTING PIN 214 SLIDE CARD 215 CHANGE SLIP 216 NOTIFICATION 217 SERVED 218 SINGLE CHECK ALL SEATS 219 SEPARATE CHECK ALL SEATS 220 SINGLE CHECK ONE SEAT 221 STORE CHECK 222 RE...

Страница 146: ...urred in the block check sum while transferring data in IRC mode DUPLICATE This check already exists May also apply to secret code programming EAT IN TAKE OUT DRIVE THRU This operation is set for comp...

Страница 147: ...NEGATIVE This sale has gone negative Negative sales are programmed as not allowed NO CHECK This message appears when the system cannot find this guest check number NO DATA PLU cannot be found does not...

Страница 148: ...ion P BAL REQUIRED This register has been programmed to require a previous balance entry PAPER END The guest check printer has reached the end of the form or the Receipt Journal paper is at or near th...

Страница 149: ...TE REQUIRED The operator is in the middle of a waste operation and must depress the WASTE key in order to complete the operation WRONG EMPLOYEE The employee attempting to open this guest check is not...

Страница 150: ...device i e printer or kitchen video that is connected to a serial port and to match the baud rate parity etc between the serial port and the printer This program also controls the feed lines before a...

Страница 151: ...is disrupted If you are using kitchen printers select Kitchen Printer Routing to link kitchen printer groups with a printer The groups of items are defined by assigning PLU items to PLU Status groups...

Страница 152: ...periods The active routing period can be controlled automatically by time or set manually Priority printing is also controlled with this program The order in which items are printed on the kitchen pri...

Страница 153: ...ou must list each item and the qualifying quantity that must be purchased on the promotion table program screen Enter the amount of the combination discount in the discount price field 3 Fixed Price T...

Страница 154: ...allowed see General Function Option Definitions on page 104 you can copy the attributes of a PLU to a range of PLUs COPY PLU STATUS GROUP Copies the attributes of one PLU Status Group to a range of o...

Страница 155: ...BY RANGE ALL FUNCTION KEYS SYSTEM OPTION TAXES MESSAGES TIME PERIOD EMPLOYEE BY RANGE JOB CODE PAY RATE AUTHORITY LEVEL PRINTER TABLES KV ROUTING INGREDIENT INVENTORY TIME ACTIVATED FUNCTION PRODUCT M...

Страница 156: ......

Страница 157: ...SPS 500 Program Manual v1 31 Reports 157 Reports Report Menu Turn the key lock to X position to view the report menu Note An employee must be signed on to view the menu...

Страница 158: ...ted Group X1 Z1 X5 Z5 Individual IRC Top 20 PLUs X1 Z1 X5 Z5 Individual IRC PLU Zero Sales X1 Z1 X5 Z5 Individual IRC PLU Zero Sales By Group X1 Z1 X5 Z5 Individual IRC PLU Sales By Price Level X1 Z1...

Страница 159: ...4 By Time Periods X1 Z1 X5 Z5 Individual IRC Open Check For Track 1 X Z IRC Open Check For Track 2 X Z IRC Open Check For Track 3 X Z IRC Open Check For Track 4 X Z IRC Open Check For Selected Employe...

Страница 160: ...and they are not consolidated Time Keeping reports should be available at any time from any register though IRC communication 3 The prepoll report will print out any reports that mightbe left in the...

Страница 161: ...the key lock to the X position and touch CASH DECLARATION to display the Cash Declaration Screen Enter an amount and press the appropriate tender key Repeat to enter additional amounts After completi...

Страница 162: ...k entries 1 Turn the key lock to the X position 2 Touch X MODE PGM and then TIME CLOCK EDIT 3 Select the period to be edited X Z DAILY EDIT or periodic edits if they are used 4 Enter the Employee touc...

Страница 163: ...k to the X position 2 Touch X MODE PGM and then EDIT INVENTORY ITEM Date Time Setting 1 Turn the key lock to the X position 2 Touch X MODE PGM and then touch DATE TIME SETTING The RTC SETTING real tim...

Страница 164: ...mined by memory allocation use the PREV RECORD NEXT RECORD key to view additional employees After making settings touch CLOSE FTP Transmission Reserved for future use Receipt Reprint Receipt copies ca...

Страница 165: ...l available on the dealer support pages of www crs usa com details the programming and operation of the SPS 500 in integrated payment applications using Datacap DataTran devices Report Samples Refer t...

Страница 166: ...166 Reports SPS 500 Program Manual v1 31...

Страница 167: ...X1 Z1alsoX5toZ5 INDIVIDUAL IRC 02 SalesbyTimePeriod X1 Z1alsoX5toZ5 INDIVIDUAL IRC 03 AllPLUs X1 Z1alsoX5toZ5 INDIVIDUAL IRC 04 From ToPLU availableversion1 00sorlater X1 Z1alsoX5toZ5 INDIVIDUAL IRC...

Страница 168: ...DIVIDUAL IRC 25 GroupsByTimePeriod X1 Z1alsoX5toZ5 INDIVIDUAL IRC 26 Destination1ByTimePeriod X1 Z1alsoX5toZ5 INDIVIDUAL IRC 27 Destination2ByTimePeriod X1 Z1alsoX5toZ5 INDIVIDUAL IRC 28 Destination3B...

Страница 169: ...idualGroup X1 Z1 INDIVIDUAL IRC 58 FoodCost X1 Z1 IRC 59 PLUMinimumStock X1 Z1 INDIVIDUAL IRC 60 ElectronicJournal X1 Z1 INDIVIDUAL 61 StringReport1 asdefinedbyprogram X1 Z11 INDIVIDUAL IRC 62 StringR...

Страница 170: ...1 3 digit 18 From To Groups From To Group number 4 digits If from group number is 1 and to group number is 2 option data is 0102 19 Selective Groups Group number 1 2 digit 41 Product Projections Week...

Страница 171: ...p to determine the operations that are allowed for each employee For example in a restaurant an authority level with the descriptor kitchen help could be set to allow only clocking in out or an author...

Страница 172: ...ogress All current items are removed voided Check Cash Use the CHECK CASH function to exchange a check for cash outside of a sale Check Endorse If compulsory check endorsement is set with the CHECK ke...

Страница 173: ...nformation Default Program The original program installed in the SPS 5X0 The register has a default program which makes it operational after a RAM clear Nearly all option rate and status programs are...

Страница 174: ...out HALO limits the amount allowed to be entered in a PLU or function key Ingredient Inventory A menu explosion type inventory system is set up when PLUs are linked to a recipe number The X MODE MANA...

Страница 175: ...and pressing a function key Memory Allocation Memory allocation is a program that determines how the system memory is divided to provide the correct features for your application For example you may...

Страница 176: ...keyboard or they can be accessed by indexing a code number and pressing the PLU key PLUs can be programmed with a preset or open price PLUs record their own activity count and dollar total on any of t...

Страница 177: ...gned on until either signed off or another clerk is signed on Stock PLU Stock PLUs track the quantity of the PLU item in stock Each time the PLU is registered a whole unit subtracts from the stock cou...

Страница 178: ...d Transaction Number A count appears at the bottom of each receipt and after each transaction on the journal tape This count increases by one with each transaction report or scan Void A void operation...

Страница 179: ...erk See Employee programming CONTINUE 50 95 Control Lock 15 CURR CONV 1 5 50 95 currency symbol 117 D destination enforce 104 direct multiplication 105 DONE 50 95 E E J Detail Printing Options 123 Ele...

Страница 180: ...97 PRINT HOLD 53 98 Printer Driver Selections 61 Priority printing 114 Product Mix Group Time Periods 137 Product Mix Groups 136 Program Scan P Mode 154 PROMO 53 98 Q QUIT function key 53 98 R real t...

Страница 181: ...FT 1 6 55 98 Taxes programming 138 Time Activated Functions programming 133 TIME IN OUT 55 98 Time Keeping Options 122 TIP 1 3 55 99 TIP DECLARE 50 Tracking File Options 112 Training Mode Options 111...

Страница 182: ...ot clear memory V1 8 6 16 2010 Update logo jpg loading instructions V1 9 8 23 2010 Update Logo Image loading instructions Update PLU Quick Registration Repair Table of Contents page s V1 10 8 27 2010...

Страница 183: ...24 7 31 2012 Explanaton of Other Reports Prepoll added V1 25 8 17 2012 Added notes to Report Option Table V1 26 8 21 2012 System Option Tax Option 13 removed From To PLU report added to Report Functi...

Отзывы: