SPS-500 Program Manual v1.31
P Mode Programming
105
(9) ROUNDING SYSTEM
Use these options to eliminate the use of small value coins (i.e. pennies). Rounding up or down occurs at
subtotal or cash.
Select the ROUNDING SYSTEM field to display the ROUNDING SYSTEM PROGRAMMING
SCREEN where up to five ranges can be set. For example if you wish to eliminate pennies, the ranges
could be set as:
#1 00-02 000 (.00-.02 rounds to .00)
#2 03-07 005 (.03-.07 rounds to .05)
#3 08-09 010 (.08-.09 rounds up to .10)
(10) GLOBAL ENTRY LIMIT (0-7, 0=NO LMT)
Select an entry limit that applies to all numeric entries (i.e. amounts for PLU entry, tenders, or
multiplication.) The global entry limit will override any individually programmed limits.
(11) DIRECT MULTIPLICATION:
ENABLE
MAXIMUM DIGIT (1-5)
Direct multiplication allows you to enter a quantity and then press a preset key without using the
X/TIME
key. You can enable direct multiplication here, and also determine the maximum number of
digits for the multiplier.
(12) ALLOW PLU PRESET/HALO OVERRIDE
Override of a preset (entry of a price into a preset key) or override of a HALO (entry of a price greater
than the PLUs high amount limit can be allowed. Note: In order to override, you must also set the flag
for each individual PLU to allow override, and you must operate an employee with the authority level #18
set to allow override.
(13) SILENT KEY DEPRESSION
If Yes, the key depression tone is silenced. (Tone for errors is still active.)
(14) ALLOW OPEN ENTRY FOR SCALE PLUS
If Yes, amount entries are allowed for open scale PLUs.
(15) DEACTIVATE VOID MODE
Set to Yes to deactivate any activity in VOID mode.
(16) ALLOW PLU COPY BY RANGE
If yes, the COPY PLU command allow you to copy statuses from a single PLU to a range of PLUs. If no,
you can only copy from a single PLU to another individual PLU. See “File Management” on page 154 to
copy PLUs.
(17) ALLOW POST TENDERING
Choose Yes to allow tendering after the sale has been finalized, for the purpose of computing change
(18) EMPLOYEE: POP UP/STAY DOWN
Choose Yes to automatically sign off at the completion of a transaction. Choose No to register sales
continuously for the same employee.
Содержание SPS-500
Страница 36: ...36 Software Installation SD Utilities SPS 500 Program Manual v1 31...
Страница 70: ...70 S Mode Programming SPS 500 Program Manual v1 31...
Страница 156: ......
Страница 166: ...166 Reports SPS 500 Program Manual v1 31...