Service Mode Programming • 91
Define Port (Serial/USB)
Connection to optional POS devices is provided with two standard RS-232C serial ports and one USB
port. An optional third serial port is available. The option settings here assign the device and
communication protocol for each port.
Port Settings
1.
Move the key to the
S
lock position to display the
Service Mode
menu.
2.
From the
Service Mode
menu press
CHARGE1
until “DEFINE PORT” is selected
(or press
5
to view the option directly.)
3.
Press
CASH
. The DEFINE PORT menu displays:
DEFINE PORT
1.PORT 1
4.
Use
CHARGE1
and the
CHARGE2
keys to scroll up and down through the
Define Port
menu. Or, enter the digit (1-3) corresponding to the serial port you wish
to program. (Select or press
4
and
CASH
to set the USB port. Select or press
5
and
CASH
to print Port1, Port2 and Port3 settings.)
PORT 1
1.BAUD RATE [96]
5.
Use the
CHARGE1
and the
CHARGE2
keys to scroll up and down through the
eleven serial port options. Make settings or changes as needed.
6.
Press the
CLEAR
key to finalize and return to the DEFINE PORT screen.
Serial port Settings Screen Program Notes
#
Option
Description
1 BAUD RATE
Select 1200, 2400, 4800, 9600, 19200, 38,400, 57,600,
or 115,200 from the screen, 9600 is default.
2 PARITY
Select NONE, EVEN or ODD, NONE is default.
3 DATA BITS
Select 8 or 7 from the screen, 8 is default.
4 STOP BITS
Select 1 or 2 from the screen, 1 is default.
5 DEVICE FUNCTION
Select NONE, PC, PRINTER,
*
SCANNER, POLE,
SCALE, EFT, DATATRAN, or REMOTE JOURNAL
from the screen, NONE is default.
6 PRINTER TYPE
Select the printer type connected to this port.
7 DISPLAY
Select the pole display type connected to this port.
8 SCALE
Select the scale type connected to this port; NCI, CAS,
OZ
9 KP START LINE (0-20)
Enter the number of KP START LINE.
10 KP END LINE (0-20)
Enter the number of KP END LINE.
11 SLIP START LINE (0-20)
Enter the number of SLIP START LINE.
*The register will work with lower power USB scanners but not the Metrologic/Honeywell. The Metrologic/Honeywell