5.4.1.1
Video Crosspoint Failure
When a video crosspoint routing failure is detected by the redundant crosspoint checking
algorithm the Nucleus router controller performs one of the following actions based on the
configuration in Workbench:
•
Move the failed route to the redundant crosspoint (default when shipped).
•
Move all routes from the crosspoint module with the failure to the redundant
crosspoint module
•
Just notify the user and leave them to take appropriate action.
If one or more routes fail on a video crosspoint module this will be displayed on the Main or
Expansion Video Crosspoint Matrix Status screen. A typical example of how the buttons will
look is listed below (see Figure 35 on page 64 or Figure 36 on page 65 for button and
parameter locations):
•
Fail Found indicator
- Red
•
Fault Present indicator
- Red
•
First Failure Detected
- Failed Source and Destinations will display the first
failed route
•
XpntCardNone
- Grey
•
Failed Action
: - text as configured in Workbench
•
Sirius 830
•
XpntCardMain830
Yellow (indicates the crosspoint has failed)
•
Sirius 840/850
•
XpntCardxxxToxxx_x
- Yellow (where xxx is the failed crosspoint module)
Note:
•
See section 10.6 for details on enabling/disabling video redundancy and section
10.7 for details on setting the redundancy action on crosspoint failure.
•