Sirius 800 Series User Manual
Input Modules
Modules No Longer Supplied With New Systems C.2
Iss 5 Rev 7
Page 317
© 2017 SAM
Yellow
Remote
Command
OK
Receiving messages
from remote Nucleus
control module (the
Nucleus controller in the
frame linked to this
frame)
Sirius 830/840/850 (no expansion)
:
Off
- Expansion not used.
Sirius 850 (expanded to second frame)
:
Flashing
- receiving information and
working correctly
Red
Remote
Error
Error with messages
from remote Nucleus
control module (the
Nucleus controller in the
frame linked to this
frame)
Sirius 830/840/850 (no expansion)
:
Off
- Expansion not used.
Sirius 850 (expanded to second frame)
:
Off
- normal state,
Flashing
- the command message from
the remote router controller is corrupt or
hasn’t been received.
This communications error could be
caused by a hardware failure or incorrect
insertion. Check that the module is
inserted correctly and the four RJ45
connections between the frames are fitted
correctly (see section 12.2).
If the “Remote Error” LED is flashing at the
same time as the “Remote Command OK”
LED is flashing it suggests a mismatch in
the configuration of the Nucleus controller.
Check the controller configuration.
Blue/Green
Fugue
Status
CPU status
Flashing sequence Green, Green, Blue
-
normal operation the CPU is programmed
and running
Brief Red Flash at startup
- normal
Flashing Red
- CPU Error. Remove
module and refit to force a reboot.
Amber
Eight Diagnostic LEDs -
SAM Use Only
Normal LED Pattern Sequence
1.
All LEDs On for one Second
2.
All LEDs Off except the top LED
3.
All LEDs Off except the second
LED from the top
4.
This sequence continues until all
LEDs are Off except for the bottom
LED
5.
All LEDs Off for 10 Seconds
6.
Return to Step 1
Any other pattern - abnormal operation
contact SAM Customer Support
LED Color Label
Detail
Normal Working Status
Table 97
5915 Sirius 800 Video AHP Input Module LED Information