Sirius 800 Series User Manual
Output Modules
Modules No Longer Supplied With New Systems C.4
Iss 5 Rev 7
Page 339
© 2017 SAM
Yellow
Remote
Command
OK
Receiving messages
from remote Nucleus
control module (the
Nucleus controller in the
frame linked to this
frame)
Sirius 830/840/850
(no expansion):
Off
- Expansion not used.
Sirius 850
(expanded to second frame):
Flashing
- receiving information and
working correctly
Red
Remote
Error
Error with messages
from remote Nucleus
control module (the
Nucleus controller in the
frame linked to this
frame)
Sirius 830/840/850
(no expansion):
Off
- Expansion not used.
Sirius 850
(expanded to second frame):
Off
- normal state,
Flashing
- the command message from
the remote router controller is corrupt or
hasn’t been received.
This communications error could be
caused by a hardware failure a or
incorrect insertion. Check that the
module is inserted correctly and the four
RJ45 connections between the frames
are fitted correctly (see section 12.2).
If the “Remote Error” LED is flashing at
the same time as the “Remote
Command OK” LED is flashing it
suggests a mismatch in the
configuration of the Nucleus controller.
Check the controller configuration.
Blue/Green
Fugue
Status
CPU status
Flashing sequence Green, Green,
Blue
- normal operation the CPU is
programmed and running
Brief Red Flash at startup
- normal
Flashing Red
- CPU Error. Remove
module and refit to force a reboot.
Amber
Eight Diagnostic LEDs -
SAM Use Only
Normal LED Pattern Sequence
1.
All LEDs On for one Second
2.
All LEDs Off except the top LED
3.
All LEDs Off except the second
LED from the top
4.
This sequence continues until all
LEDs are Off except for the
bottom LED
5.
All LEDs Off for 10 Seconds
6.
Return to Step 1
Any other pattern - abnormal operation
contact SAM Customer Support
LED Color Label
Detail
Normal Working Status
Table 107 5925 Sirius 800 Video AHP Output Module LED Information (Continued)