Sirius 800 Series User Manual
Powering Up the Sirius 800
Powering the Sirius 800 Routers 4.1
Iss 5 Rev 7
Page 51
© 2017 SAM
4.1.2.1
Configuration Errors
The router controller generates an error if one or more of the configured modules in the router
fails to power up. Errors are displayed on the Door screen (see section 5.2.2) and the router
controller LEDs (see Table 7 for LED color and Figure 19 for LED position).
If the Door screen and router controller indicate that the configuration is not as expected (i.e.
modules added or missing) then this can be resolved using Workbench. For details of how to
add modules to the router see the Sirius 800 Maintenance & Upgrade manual.
4.1.3 Starting the Door PC Manually
The Door PC starts automatically when the Sirius 800 is powered up. If the Door PC has been
shut down and needs starting manually the following procedure should be used.
1.
With the Sirius 800 running open the frame door.
2.
Inside the back of the door is the power switch for the Door PC (see Figure 20).
3.
Switch the Door PC on by pressing and releasing the Door PC power switch (it will not
latch in place). Wait until the computer is fully booted up before proceeding further.
Router Controller
LED
LED Color
Nucleus2
4
Pulsing Orange
Nucleus 2450
D15
Steady Red
Table 7
Controller Mismatch Notification
Figure 20 Door PC Rear View
Door PC Power Switch
LED Power Indicator
Exhaust Fan
Power Connector