10. Problems, causes and remedies
Only allow faults to be remedied by qualified
personnel!
Follow the safety instructions in Maintenance.
If no solution can be found, please
contact your plumbing and heating
specialist or your nearest Salmson
Customer Service or representative.
11. Spare parts
Spare parts are ordered via a local specialist dealer
and/or Salmson customer service.
In order to avoid queries and incorrect orders,
make sure to mention all data indicated on the
rating plate when placing your order.
Subject to technical alterations!
Problems
Causes
remedy
Pump does not run
No voltage
Check the wires and fuses, or switch
automatic fuses in the distribution sta-
tion back on
Rotor blocked
Clean the housing and impeller, if still
blocked replace the pump
Cable rupture
Check the cable resistance. If necessary,
replace the cable. Only use genuine
Salmson special cable
Safety switches thrown
Water in the motor chamber
Contact customer service
Foreign bodies in the pump,
winding protection contact triggered
Disconnect the system from the elec-
tricity supply and secure it against being
switched on
Lift the pump out of the sump.
Remove the objects
Pump has no power
Pump drawing up air because fluid level
is too low
Check the function/setting of the level
control
Pressure pipe blocked
Detach the pipe and clean it